POSSIBLE ERRORS AT THE FIRST TIME INSTALLATION!
THE CARRIAGE DOESN’T APPLY ENOUGH OVERLAP AT PALLET TOP – PA06
Problem suggestion
Possible solution
- Timer PA06 has to be increased
- Open the hidden parameters of the
software “operating panel.
- Select parameter PA06 and increase
the value.
- This operation can only be done by a
FROMM engineer.
THE CARRIAGE HOME POSITION IS WRONG
– PA07
Problem suggestion
Possible solution
- Carriage home position
- Open the hidden parameters of the
software “operating panel.
- Select parameter PA07 and increase
or decrease the value.
- Increase = The carriage will stop
higher
- Decrease = The carriage will stop
lower
- This operation can only be done by a
FROMM engineer.
TIMER SELECTION PA08
Problem suggestion
Possible solution
- Timer selection for Movement Carriage 3.
- Single wrapping only up with automatic
return.
Movement Carriage 3
-
Open the hidden parameters of the
software “operating panel.
-
Select parameter PA08 and change
the timer.
-
This operation can only be done by a
FROMM engineer.
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER