Boiler servicing
Inspection, cleaning and maintenance
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse 12, A-4710 Grieskirchen
Page 23
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected] www.froeling.com
B0430408_en
4
Check the grate and combustion chamber
Only clean the grate and combustion chamber when the boiler has
cooled down
U
Press and hold the
key for 5 seconds
´
Boiler follows shutdown procedure and changes to the status
“Burner off”
´
The ID fan turns at a controlled speed and the combustion grate
stays in open position.
for P4 Pellet 8/15/20/25:
U
Open the insulating door, open the right ash door and pull out the
ash drawer
For P4 Pellet 32/38/48/60:
U
Open the insulating door, take out the right ash container and open
the ash door
U
Check the combustion grate and combustion chamber for dirt
U
If there is a lot of dirt, clean the combustion chamber
À
Page 24, Clean the flue gas collection chamber and the heat
exchanger