Technical information | 4
M1980822_en | Installation instructions Wood chip boiler T4e 20-180
37
Description
T4e / T4e ESP
160
170
180
kg/s
0.035
0.036
0.038
Required feed pressure at nominal load
Pa
5
mbar
0.05
Required feed pressure at partial load
Pa
2
mbar
0.02
Maximum permissible feed pressure
Pa
30
mbar
0.3
Flue pipe diameter
mm
199
4.3.12 Data for planning a backup power supply
The system can be operated with an emergency generator. The following information
must be observed during planning.
Description
Value
Continuous output (three phase)
VA
6375
Nominal voltage
VAC
400 ± 6%
Frequency
Hz
50 ± 2%