![Fröling T4e 100 Installation Instructions Manual Download Page 27](http://html1.mh-extra.com/html/froling-0/t4e-100/t4e-100_installation-instructions-manual_2338782027.webp)
Technical information | 4
M1980822_en | Installation instructions Wood chip boiler T4e 20-180
27
Regulation (EU) 2015/1189 – emissions in [mg/m³]
1)
Annual space heating emissions of gaseous organic compounds
(GOC)
≤ 20
Annual space heating emissions of carbon monoxide (CO)
≤ 380
Annual space heating emissions of nitrogen oxides (NO
x
)
≤ 200
1. The emissions of dust, gaseous organic compounds, carbon monoxide and nitrogen oxides are stated in a standardised form based on dry flue gas with a oxygen content of 10 % and
under standard conditions at 0°C and 1013 millibar
4.3.6 T4e 80 - 110 ESP
Description
T4e 80 – 110 ESP
80
90
100
108
1)
110
Rated heat output
kW
80
90
100
108
110
Electrical connection
400V / 50Hz / fused C16A
Weight of boiler (including stoker, without water)
kg
1160
Boiler capacity (water)
l
228
Available feed height of pump
2)
(with ΔT = 20K)
mbar
628
566
525
473
460
Max. permitted operating temperature
°C
90
Permitted operating pressure
bar
4
Boiler class as per EN 303-5: 2012
5
Airborne sound level
dB(A)
<70
Permitted fuel acc. to EN ISO 17225
3)
Part 4: Wood chips class A2 / P16S-P31S
Part 2: Wood pellets class A1 / D06
Test book number
PB 137
PB 138
PB 139
PB 140
1. T4e 108 ESP only available in the Italian language
2. Pump output less water resistance in the boiler
3. Detailed information on the fuel can be found in the operating instructions in the section entitled “Permitted fuels”
Regulation (EU) 2015/1187
Heating space annual rate of use ηs
%
≥ 78
Additional data for regulation (EU) 2015/1189
Description
T4e 80 – 110 ESP
80
90
100
108
110
Heating up mode
automatic
Condensing boiler
No
Solid fuel boiler for combined heat and power
No
Combined heating system
No
Storage tank volume
Characteristics when operated exclusively with the preferred fuel
Useful heat delivered at rated heat output (P
n
)
kW
80
90
100
108
110
Useful heat delivered at 30% of rated heat output (P
p
)
24.0
27.0
30.0
32.4
33.0
Fuel efficiency at rated heat output (η
n
)
%
83.8
83.7
83.7
83.7
83.7