2 | Installing the RBG 3200
6
B0640421_en | Operating instructions Control Panel RBG 3200
End jumper not set
End jumper set
If the contacts at the base of the end jumper are not bridged (image left), it is referred
to as “not set". In this case there is no bus termination. If the contacts are closed
(image right), the end jumper is set and the bus connection is terminated.
2.3 Setting the module address
You must set the required order with the module addresses for the RBG 3200 (display
module). The standard boiler comes with a display module (boiler display) with the
address 0 (except S3 Turbo with S-Tronic controller). If you, therefore, install an
additional display module, set it to address 1 so that the standard hydraulic system
settings do not need to be reconfigured. Set all further RBG 3200s module addresses
in ascending order (2 to 7).
Important! Only set the module address when the device is disconnected from
the power supply!