5 | Parameters overview
16
B0640421_en | Operating instructions Control Panel RBG 3200
5 Parameters overview
5.1 Heating
5.1.1 Heating - Status
Basic
display
Heating
Heating
circuit 1
State
Heating circuit mode
Display and setting the heating circuit mode:
Auto:
Automatic: heating phases according to the set heating times
Extra heating:
The heating circuit is regulated to the set room temperature with no time limitation.
To cancel this function, activate another mode/function
Setback:
Setback mode; the current or next heating phase is ignored
Continuous setback mode:
Heating circuit remains in setback mode until another mode is activated
Party:
Party mode; the current or next setback phase is ignored
OFF:
Switched off; heating circuit deactivated, only frost protection!
Actual flow temperature
Display of the current flow temperature.
Flow temperature setpoint
Display of the calculated flow temperature setpoint.
Room temperature
Prerequisite:
Heating circuit used in conjunction with remote control
Display of the current room temperature.
Outside air temperature
Display of the current outside air temperature.