4.

 

Indoor humidity calibration. 

5.

 

Absolute pressure calibration. 

 
In calibration mode, press + and - buttons to adjust offset values, then press 

SET

 to confirm and 

proceed to next parameter. Press the 

ALARM

 button to cancel offset values. 

 
During calibration mode, press 

LIGHT/SNOOZE

 to exit calibration mode. 

 
Please note Offset values range as below: 
Temperature offset calibrated (range +/-9F, default: 0 degrees). 
Humidity offset calibrated (range +/-9%) 
Pressure offset calibrated (range +/-10hpa) 
 

5.6 MAX/MIN Mode 

The Max/Min weather data are displayed on the bottom of each parameter segment. Left one in 
red color is MAX record, right one in blue or yellow is MIN record. All the MAX/MIN records are 
based on since last reset time after turned on. 
 

                                   

 

 

Max temperature      Min temperature            Max humidity Min humidity 

 
All MAX/MIN records can be cleared if you press and hold the TEMP button 2 seconds. 
 
MAX/MIN

 

records  are  cleared  on  0:00  every  day  default.  And  below  MAX/MIN  DAILY  icon 

would be displayed on console. You can switch off this automatically clearing function in setting 
mode  (Refer  to  5.1.2  2.RST  ON/OFF  in  Set  Mode  Quick  Reference  Guide),  and  this  icon  would 
disappear. 
 

 

5.7

 

Other Console Features 

5.7.1 Color Weather Forecasting 

This station learns. Please allow 30 days for barometric calibration. This will ensure an  accurate 
personal forecast for your location. 
 
Six color forecast icons use changing atmospheric pressure to predict weather conditions for the 
next 12-hours . 

Summary of Contents for WH2800

Page 1: ...2 Product Features Figure 1 1 Wireless outdoor and indoor humidity RH 2 Wireless outdoor and indoor temperature F or C 3 Records min and max humidity 4 Records min and max temperature 5 Barometric pre...

Page 2: ...section remote transmitter first display console second to avoid the console synchronization time out This weather station consists of a console receiver a thermo hygrometer remote transmitter and a...

Page 3: ...We recommend lithium batteries for cold weather climates but alkaline batteries are sufficient for most climates We do not recommend rechargeable batteries They have lower voltages do not operate wel...

Page 4: ...t the polarity is for the top battery for the middle battery and for the bottom battery Note To avoid permanent damage please take note of the battery polarity before inserting the batteries The displ...

Page 5: ...nished In some locations RCC reception may take a couple of days to receive the signal The temperature and humidity data will continue to transmit during this period Once the radio controlled time is...

Page 6: ...n 4 F the accuracy is 2 F Allow about 30 minutes for both sensors to stabilize 4 Sensor Placement It is recommended you mount the remote sensor outside on a north facing wall in a shaded area at a hei...

Page 7: ...ss TEMP or BARO to toggle between 12 hour 12h and 24 hour 24h format SET Hour of Day Press TEMP to increase BARO to decrease SET Minute of Day Press TEMP to increase BARO to decrease SET D M M D Forma...

Page 8: ...ss the TEMP key or BARO key to adjust the hour up or down 6 Change Minute Press the SET key again to set the minute Press the TEMP key or BARO key to adjust the minute 7 D M M D Format ress the SET ke...

Page 9: ...pressure decreases as you rise in altitude the sea level corrected pressure the pressure your location would be at if located at sea level is generally higher than your measured pressure Thus your ab...

Page 10: ...off the Ice ALARM Refer to 5 4 2 5 Returns to the normal display mode 5 4 2 Ice ALARM Ice ALARM is an ALARM happens when outdoor temperature falls into or goes up to 3 2 c range A snow icon will appea...

Page 11: ...right one in blue or yellow is MIN record All the MAX MIN records are based on since last reset time after turned on Max temperature Min temperature Max humidity Min humidity All MAX MIN records can...

Page 12: ...udy Cloudy Rainy Stormy Snowy Note Snowy icon will appear in place of rainy and stormy icons when the outdoor temperature is below 0 C 32 F 5 7 2 Moon phase The following moon phases are displayed bas...

Page 13: ...the remote sensor or transmitter and the display console or the receiver to resynchronize while in normal mode Press and hold SET and TEMP button for 5 seconds to register the outdoor transmitter Plea...

Page 14: ...on in open air 100meter 300 feet Frequency 433 MHz 868 MHz 915 MHz Update Rate 64 seconds 7 2 Measurement Specifications The following table provides specifications for the measured parameters Measure...

Page 15: ...ir consequences All trademarks and property rights are recognized www froggit de HS Group GmbH Co KG Escherstr 31 50733 Koeln Germany Telefon E Mail 0221 367 48 05 info hs group de Registergericht Amt...

Reviews: