background image

20

1.

3.

4.

5.

2.

Troubleshooting

1. Make sure your filtration 
system is working properly (i.e. 
clean filter, skimmer and pump 
basket).
2. Make sure circulation time 
is adequate – increase pump 

time if not.
3. Make sure the pool is 
properly balanced. 

(See page 10.)

4. Shock the water to eliminate 
build up of any organic matter.

5. Make sure pool has a 
free chlorine reading of 
0.5 to 1.0 ppm.
6. Check with your dealer 
for more information.

1. Algae may be trying to form 
– shock the pool, increase 
circulation time if needed and 
clean the filter. 

2. Metals in the fill water may 
have been oxidized. Have the 
pool tested. See pool dealer 
if a metal control product is 
required.

3. Check with your dealer for 
more information.

1. Use FROG Leap All-Out or 
an effective algaecide per the 
directions on the bottle and 
brush the sides of the pool often.
2. Clean the filter and shock 
the pool with chlorine daily until 

water clarity returns.
3. If you are in an area of 
the country that struggles 
with algae growth, see your 
dealer regarding a 90-day 
Algae-Protection Guarantee 

using FROG Leap All-Out.  

See product hang tag for 
guarantee details.

4. Check with your dealer for 
more information.

1. If you are unable to 
maintain 0.5 to 1.0 ppm, first 
make sure there are chlorine 
tablets in the tower areas of 
the FROG Leap Torpedo Pac 
and it is installed properly. If a 
correction was made, test the 
water in 24 hours. 
2. If still low, turn the dial up 
one setting and test the water 
again in 24 hours. Continue 
raising the setting by one 
increment each day until the 

proper reading is achieved.
3. Shock the pool if the reading 
has been lower than 0.5 ppm 
for more than one day. 
4. Make sure pump run time is 
at least 6 hours on high speed 
(40 gpm or higher) or if not, 
bleed the air from the back 
knob each time cap is open. 
5. Contact your dealer to have 
your back pressure tested. If 
under 4 psi, consider a smaller 

eyeball fitting in the return jet.
6. Check for a suction side 
leak by looking for air bubbles 
in your pump basket or at the 
return jet. Contact dealer for 
help in correcting this situation.
7. Contact King Technology’s 
Customer Service Department 
at 800-222-0169.

1. If the chlorine reading is 
over 3.0 ppm, remove the 
FROG Leap Torpedo Pac 
from the FROG Leap Anti-Bac 
Mineral Pac and test the water 
daily until the reading is down 
to 1.0 ppm.
2. Reinsert the FROG Leap 
Torpedo Pac, lower the dial 
one setting and test the 
water again in 24 hours. If 
the reading has risen, lower 
the dial one setting again. 
Continue this process until 

proper reading is achieved.  
3. If over-chlorinating at 
the lowest possible setting, 
consider decreasing the 
circulation time. Depending on 
your pump size, you may be 
circulating the water more than 
is necessary.
4. Contact your dealer to have 
your back pressure tested. If 
over 8 psi consider a larger 
eyeball fitting in the return jet.
5. Check to see if the pressure 
relief valve is loose or missing 

and replace. See parts diagram 
on page 21.
6. If these steps are not 
successful and your Infuzer is 
installed using the 6” nipple, 
we have found changing 
the installation can make a 
difference. You will need a 
section of flex hose and 2 hose 
adapters to do this. See page 8 
for directions.
6. Contact King Technology’s 
Customer Service Department 
at 800-222-0169. 

What do I do 
if I am over 
chlorinating with 
the FROG Leap 
Torpedo Pac?

What do I do 
if I am under 
chlorinating with 
the FROG Leap 
Torpedo Pac?

What do I do 
if algae forms in or 
on my pool?

What do I do 
if the water turns 
color?

What do I do 
if the water looks 
cloudy?

Problem

Remedy

For more in-depth troubleshooting, go to frogproducts.com or call King Technology at 800-222-0169.

Summary of Contents for Leap 7800

Page 1: ...Clearer because it helps keep pH in range Softer because it reduces chlorine use up to 50 Easier with prefilled pacs for no mess no guess and no stress To minimize the risk of serious injury death or...

Page 2: ...0 11 Step 2 Putting the System to Work 12 Step 3 Setting the Control Dial 13 Step 4 Routine Pool Care 14 Replacing FROG Leap Anti Bac Mineral Pac 15 Using FROG Leap Pool Wake Up 16 Using FROG Leap All...

Page 3: ...Anti Bac Mineral Pac Part No 01 03 7937 FROG Leap Anti Bac Mineral Pac comes inside the FROG Leap Infuzer and is also sold separately Also sold separately FROG Leap Torpedo Pac FROG Leap All Out Part...

Page 4: ...ctographs illustrate the type of hazard Pictograph Type of Danger Safety Alert General Hazard Explosion Risk Hazardous Pressure Flammable Fire Hazard Identification of warnings Warnings are intended t...

Page 5: ...OG Leap Torpedo Pacs FROG Leap Anti Bac Mineral Pacs FROG Leap Pool Wake Up Pool Hibernation which includes FROG Leap Reveille FROG Leap Depth Charge and FROG Leap All Out in the FROG Leap Infuzer Nev...

Page 6: ...OOL RETURN FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer IN FLOOR CLEANER VALVE FILTER FILTER HEATER OPTION 2 A 3 Way Valve Installation POOL WATER LEVEL 3 way manual valve o...

Page 7: ...ipe thread tape or sealant to each threaded end of nipple 1 Screw either side of FROG Leap Infuzer on to open nipple end until upright and secure Apply pipe thread tape or sealant to threaded end of h...

Page 8: ...tions with pipe wrench DO NOT OVER TIGHTEN 2 Attach the filter section of flex hose to one hose adapter and the return section of flex hose to the other hose adapter with clamps and tighten with screw...

Page 9: ...b 3 Pipe Wrench Bi flow valve design allows installation in either flow direction Pipe Thread Tape or Sealant Primer and PVC Cement If using male adapters apply pipe thread tape or sealant to the thre...

Page 10: ...e adding to the pool If calcium content is higher than 400 ppm find a soft water source to fill your pool instead otherwise water balance will be very difficult Check for metals in the pool such as ir...

Page 11: ...low 80 ppm Important Keep cap on tight between uses Store at room temperature www KingTechnology com Patent 6 030 842 Made in USA 553101443N Read v w IDEAL USE BY DATE ON BOTTLE USE ANTES FECHA SmartC...

Page 12: ...ap Anti Bac Mineral Pac in the Infuzer See page 17 for directions Use FROG Leap All Out for a 90 day Algae Protection Guarantee When chlorine reading is down to 1 0 ppm which may take a few days inser...

Page 13: ...RECOMMENDED FLOW RATE 20 60 gpm NR This pump size is not recommended for this size pool 24 HOUR LOW SPEED PUMP RUN TIME In order to ensure proper performance when running the pump on low speed for 24...

Page 14: ...maintaining water balance regularly is important WARNING TopreventthebuildupofgaspressureintheFROGLeap Infuzer besurethepoolreturnlinevalvesareopenexcept whenopeningorservicingtheunit DANGER Never ad...

Page 15: ...h fin inside the FROG Leap Infuzer Lower FROG Leap Anti Bac Mineral Pac into FROG Leap Infuzer until secure Replace the FROG Leap Torpedo Pac inside the FROG Leap Anti Bac Mineral Pac to continue oper...

Page 16: ...p 1 2 3 4 FROG Leap Depth Charge FROG Leap Reveille Run the pump and filter for each pac according to the directions on the product label Remove from the FROG Leap Infuzer when empty and discard in tr...

Page 17: ...in FROG Leap Infuzer to puncture seal Replace cap by hand only DO NOT OVER TIGHTEN Turn control dial on FROG Leap Infuzer to Setting 10 2 3 4 5 Turn pump on for 90 minutes allowing FROG Leap All Out...

Page 18: ...ROG Leap Torpedo Pac is required to assure up to 50 reduction in chlorine use FROG Leap Torpedo Pac sold separately EPA Reg No 53735 2 2 3 4 5 6 7 Replace cap by hand only DO NOT OVER TIGHTEN The chlo...

Page 19: ...in If FROG Leap Torpedo Pac still contains chlorine wrap in plastic bag and store in shed or cool dry well ventilated location away from children pets cars motorcycles or anything metal that can rust...

Page 20: ...r if not bleed the air from the back knob each time cap is open 5 Contact your dealer to have your back pressure tested If under 4 psi consider a smaller eyeball fitting in the return jet 6 Check for...

Page 21: ...ipple Kit 1 Replacement parts for FROG Leap Infuzer 7800 REF PART NO DESCRIPTION 1 2 01 22 1426 Cap w O Ring 2 01 22 1922 Cap O Ring 4 01 22 9485 Pressure Relief Valve 5 6 7 8 01 22 1457 Control Dial...

Page 22: ...al until it locks into place Lubricate O ring every couple of months with silicone lubricant that came with your FROG Leap Infuzer DO NOT USE petroleum based lubricants 1 1 2 2 3 4 5 5 SILICONE LUBRIC...

Page 23: ...f the chemicals used in the product or their characteristics 3 Any express warranty not provided for herein and any remedy for breach of warranty or breach of contract which but for this provision mig...

Page 24: ...g Technology Inc FROG FROG Leap Torpedo Pac FROG Leap FROG Leap Pool Wake Up Pool Hibernation FROG Leap Anti Bac Mineral Pac Fresh Mineral Water 530 11TH AVE S HOPKINS MN 55343 800 222 0169 frogproduc...

Reviews: