background image

18

Remove colored caps by grabbing on 
to the lip of one cap with a pliers and 
pulling up until cap releases. Repeat 
the process for the other cap.

Invert FROG Leap Torpedo Pac and 
shake slightly until chlorine tablets fall 
into tower areas.

Top View

FROG Leap 
Anti-Bac 
Mineral Pac

FROG Leap 
Torpedo Pac

Mark your calendar ahead for the 
approximate replacement times 
for the FROG Leap Torpedo Pac. 

Line up small leg of the FROG 
Leap Torpedo Pac with small 
opening in FROG Leap Anti-Bac 
Mineral Pac, and large leg with 
large opening. Lower FROG Leap 
Torpedo Pac into FROG Leap Anti-
Bac Mineral Pac until secure.

Using 

FROG Leap Torpedo Pac

FROG Leap Torpedo Pac is required to 
assure up to 50% reduction in chlorine 
use*. FROG Leap Torpedo Pac sold 
separately.
(EPA Reg. No. 53735-2)

2.

3.

4.

5.

6.

7.

Replace cap by hand only. 

DO NOT OVER TIGHTEN.

The chlorine pac container is 
made of HDPE plastic. Non-
refillable container. Do not reuse 
or refill this container. Rinse 
thoroughly before discarding in 
trash or offering for recycling if 
available.

WE RECYCLE

1.

Turn off pump. Turn 
control dial to 0. Remove 
cap from FROG Leap 
Infuzer and stand back 
to let any chlorine fumes 
dissipate. 

IMPORTANT: 

Read the label on the FROG Leap Torpedo Pac  

 

 

carefully before using.

WARNING

Avoid sparks, smoking, or any open flame near 
FROG Leap Infuzer or chemicals.

DANGER

 

Never use fast dissolving chlorine tablets, liquid bleach, 
or calcium hypochlorite in the FROG Leap Infuzer.

PAC 

TOWERS

PAC 

TOWERS

Colored
Caps

Summary of Contents for Leap 7800

Page 1: ...Clearer because it helps keep pH in range Softer because it reduces chlorine use up to 50 Easier with prefilled pacs for no mess no guess and no stress To minimize the risk of serious injury death or...

Page 2: ...0 11 Step 2 Putting the System to Work 12 Step 3 Setting the Control Dial 13 Step 4 Routine Pool Care 14 Replacing FROG Leap Anti Bac Mineral Pac 15 Using FROG Leap Pool Wake Up 16 Using FROG Leap All...

Page 3: ...Anti Bac Mineral Pac Part No 01 03 7937 FROG Leap Anti Bac Mineral Pac comes inside the FROG Leap Infuzer and is also sold separately Also sold separately FROG Leap Torpedo Pac FROG Leap All Out Part...

Page 4: ...ctographs illustrate the type of hazard Pictograph Type of Danger Safety Alert General Hazard Explosion Risk Hazardous Pressure Flammable Fire Hazard Identification of warnings Warnings are intended t...

Page 5: ...OG Leap Torpedo Pacs FROG Leap Anti Bac Mineral Pacs FROG Leap Pool Wake Up Pool Hibernation which includes FROG Leap Reveille FROG Leap Depth Charge and FROG Leap All Out in the FROG Leap Infuzer Nev...

Page 6: ...OOL RETURN FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer IN FLOOR CLEANER VALVE FILTER FILTER HEATER OPTION 2 A 3 Way Valve Installation POOL WATER LEVEL 3 way manual valve o...

Page 7: ...ipe thread tape or sealant to each threaded end of nipple 1 Screw either side of FROG Leap Infuzer on to open nipple end until upright and secure Apply pipe thread tape or sealant to threaded end of h...

Page 8: ...tions with pipe wrench DO NOT OVER TIGHTEN 2 Attach the filter section of flex hose to one hose adapter and the return section of flex hose to the other hose adapter with clamps and tighten with screw...

Page 9: ...b 3 Pipe Wrench Bi flow valve design allows installation in either flow direction Pipe Thread Tape or Sealant Primer and PVC Cement If using male adapters apply pipe thread tape or sealant to the thre...

Page 10: ...e adding to the pool If calcium content is higher than 400 ppm find a soft water source to fill your pool instead otherwise water balance will be very difficult Check for metals in the pool such as ir...

Page 11: ...low 80 ppm Important Keep cap on tight between uses Store at room temperature www KingTechnology com Patent 6 030 842 Made in USA 553101443N Read v w IDEAL USE BY DATE ON BOTTLE USE ANTES FECHA SmartC...

Page 12: ...ap Anti Bac Mineral Pac in the Infuzer See page 17 for directions Use FROG Leap All Out for a 90 day Algae Protection Guarantee When chlorine reading is down to 1 0 ppm which may take a few days inser...

Page 13: ...RECOMMENDED FLOW RATE 20 60 gpm NR This pump size is not recommended for this size pool 24 HOUR LOW SPEED PUMP RUN TIME In order to ensure proper performance when running the pump on low speed for 24...

Page 14: ...maintaining water balance regularly is important WARNING TopreventthebuildupofgaspressureintheFROGLeap Infuzer besurethepoolreturnlinevalvesareopenexcept whenopeningorservicingtheunit DANGER Never ad...

Page 15: ...h fin inside the FROG Leap Infuzer Lower FROG Leap Anti Bac Mineral Pac into FROG Leap Infuzer until secure Replace the FROG Leap Torpedo Pac inside the FROG Leap Anti Bac Mineral Pac to continue oper...

Page 16: ...p 1 2 3 4 FROG Leap Depth Charge FROG Leap Reveille Run the pump and filter for each pac according to the directions on the product label Remove from the FROG Leap Infuzer when empty and discard in tr...

Page 17: ...in FROG Leap Infuzer to puncture seal Replace cap by hand only DO NOT OVER TIGHTEN Turn control dial on FROG Leap Infuzer to Setting 10 2 3 4 5 Turn pump on for 90 minutes allowing FROG Leap All Out...

Page 18: ...ROG Leap Torpedo Pac is required to assure up to 50 reduction in chlorine use FROG Leap Torpedo Pac sold separately EPA Reg No 53735 2 2 3 4 5 6 7 Replace cap by hand only DO NOT OVER TIGHTEN The chlo...

Page 19: ...in If FROG Leap Torpedo Pac still contains chlorine wrap in plastic bag and store in shed or cool dry well ventilated location away from children pets cars motorcycles or anything metal that can rust...

Page 20: ...r if not bleed the air from the back knob each time cap is open 5 Contact your dealer to have your back pressure tested If under 4 psi consider a smaller eyeball fitting in the return jet 6 Check for...

Page 21: ...ipple Kit 1 Replacement parts for FROG Leap Infuzer 7800 REF PART NO DESCRIPTION 1 2 01 22 1426 Cap w O Ring 2 01 22 1922 Cap O Ring 4 01 22 9485 Pressure Relief Valve 5 6 7 8 01 22 1457 Control Dial...

Page 22: ...al until it locks into place Lubricate O ring every couple of months with silicone lubricant that came with your FROG Leap Infuzer DO NOT USE petroleum based lubricants 1 1 2 2 3 4 5 5 SILICONE LUBRIC...

Page 23: ...f the chemicals used in the product or their characteristics 3 Any express warranty not provided for herein and any remedy for breach of warranty or breach of contract which but for this provision mig...

Page 24: ...g Technology Inc FROG FROG Leap Torpedo Pac FROG Leap FROG Leap Pool Wake Up Pool Hibernation FROG Leap Anti Bac Mineral Pac Fresh Mineral Water 530 11TH AVE S HOPKINS MN 55343 800 222 0169 frogproduc...

Reviews: