All models ...........................................................................................................................0.05 mm (0.002”)
I
MPELLER
G
APS
TO
h
OUSING
T
O
C
OVER
700, 710, 720, 740, 1740....................................................... 0.5 mm (0.020”) ....... 0.5 mm (0.020”)
352......................................................................................... 0.5 mm (0.020”) ........ 1 mm (0.040”)
353, 1050............................................................................... 1 mm (0.040”) ........... 0.5 mm (0.020”)
354......................................................................................... 1 mm (0.040”) ........... 1 mm (0.040”)
345, 355................................................................................. 1.5 mm (0.060”) ........ 0.5 mm (0.020”)
1150, 1160............................................................................. 1.5 mm (0.060”) ........ 2.0 mm (0.080”)
R
ECOMMENDED
P
REVENTIVE
M
AINTENANCE
R
ECOMMENDED
S
EAL
M
AINTENANCE
Visually inspect mechanical seal daily for leakage.
Replace mechanical seal annually under normal duty.
Replace mechanical seal as often as required under heavy duty.
E
LASTOMER
I
NSPECTION
Inspect all elastomers when performing pump maintenance. We recommend replacing elastomers (o-
rings and gaskets) during seal, pump shaft and/or motor replacement. If the impeller nut gasket fails,
the threaded hole on the impeller nut and the threads on the end of the shaft will need to be cleaned. A
wire brush is recommended for cleaning these threads.
M
OTOR
L
UbRICATION
R
ECOMMENDATIONS
Use a high grade ball and roller bearing grease. Recommendations for standard service conditions
include
Shell Dolium R
or
Chevron SRI
. (See
Tables 1-3
for more details.)
Table 1: Motor Lubrication Intervals for Standard Conditions*
Frame Size: NEMA (IEC)
3500 RPM 1750 RPM
Up to 210 incl. (132 IEC)
5,500 hrs. 12,000 hrs.
Over 210 to 280 incl. (180 IEC)
3,600 hrs. 9,500 hrs.
Over 280 to 360 incl. (225 IEC)
2,200 hrs. 7,400 hrs.
*For severe conditions, multiply interval hours by 0.5; for extreme conditions, multiply interval hours by 0.1
Table 2: Service Conditions Definitions
Service
Conditions
Max. Ambient
Temperature
Atmospheric Contamination
Standard
104°F (40°C)
Clean, little corrosion
Severe
122°F (50°C)
Moderate dirt, corrosion
Extreme
>122°F (50°C)
Severe dirt, abrasive dust, corrosion
Table 3: Volume of Grease to be Added per Bearing
Frame Size
NEMA (IEC)
Grease
IN
3
Volume
TSP
Up to 210 incl. (132 IEC)
0.6
2.0
Over 210 to 280 incl. (180 IEC)
1.2
3.9
Over 280 to 360 incl. (225 IEC)
1.5
5.2
Summary of Contents for FP Series
Page 10: ...Fristam FP FPX Series Pump 10 Single Seal Assembly ...
Page 11: ...Fristam FP FPX Series Pump 11 Single Seal Assembly Split Centered style ...
Page 12: ...Fristam FP FPX Series Pump 12 Double Seal Assembly ...
Page 13: ...Fristam FP FPX Series Pump 13 Double Seal Assembly Split Centered style ...
Page 28: ...Fristam FP FPX Series Pump 28 Pump Maintenance Record Date Service Performed By ...
Page 29: ...Fristam FP FPX Series Pump 29 Pump Maintenance Record Date Service Performed By ...