The standard FP/FPX centrifugal pump versions are designed for use in hygienic applications. Each
pump is specified according to customer specifications, including performance and materials of con-
struction. The pump may only be used for the application it was specified for.
General Specifications:
• Motor sizes up to 75 HP
• Flow rate up to 900 GPM
• Viscosity up to 1200 CPS
• Inlet pressure up to 150 psi
• Discharge pressure up to 450 ft. head / 195 psi
I
MPROPER
U
SE
The standard FP/FPX centrifugal pump versions may not be used in explosive atmospheres. Special
explosion-proof versions may be available. Please consult Fristam for more information.
Pumping media other that those specified can cause serious damage to the pump and/or personnel.
Any modifications to the pump or its use are only permissible with the explicit consent of Fristam.
S
TART
-
UP
INSTRUCTIONS
• Remove any foreign matter that may have entered the pump.
• Turn shaft by hand to make sure seals do not stick together otherwise, if motor is bumped in
wrong direction it may unwind the seal spring.
• Do not use the pump to flush the system!
Check pump for proper rotation as indicated on the pump.
Proper motor direction is clockwise when
looking at the fan end of the motor.
(NOTE: When checking the direction of rotation, the pump must
be full of liquid.)
• Never run the pump dry, even momentarily. Seal damage can result.
S
hUT
-
DOWN
INSTRUCTIONS
• Shut off the power supply to the pump.
• Close the shut-off valves in the suction and discharge piping.
• Drain and clean the pump.
• Protect the pump against dust, heat, moisture and impact damage.
C
LEANING
SIP P
ROCESS
FP/FPX series pumps should only be used for SIP (Sterilization In Place) process with the prior ap-
proval of Fristam. Suitability may depend on selected elastomers and/or process temperatures.
Summary of Contents for FP Series
Page 10: ...Fristam FP FPX Series Pump 10 Single Seal Assembly ...
Page 11: ...Fristam FP FPX Series Pump 11 Single Seal Assembly Split Centered style ...
Page 12: ...Fristam FP FPX Series Pump 12 Double Seal Assembly ...
Page 13: ...Fristam FP FPX Series Pump 13 Double Seal Assembly Split Centered style ...
Page 28: ...Fristam FP FPX Series Pump 28 Pump Maintenance Record Date Service Performed By ...
Page 29: ...Fristam FP FPX Series Pump 29 Pump Maintenance Record Date Service Performed By ...