9
ELECTRONIC CONTROL FEATURES
PRO-SELECT™ ELECTRONIC CONTROL
FEATURES
Replace Air Filter
When the “REPLACE AIR FILTER” LED is illuminated
yellow, the air
fi
lter needs to be replaced. The control
will signal for air
fi
lter replacement after 3600 hours
of refrigerator operation. After replacing the air
fi
lter,
reset the air
fi
lter timer by pressing the AIR FILTER key
for 3 seconds. The “REPLACE AIR FILTER” LED will be
illuminated green for three (3) seconds, con
fi
rming a
timer reset.
Control Lock
To disable the keypads on the control, begin by pressing
the CONTROL LOCK key for three seconds until “LO” is
displayed for 1 second. With the control locked, when
keys are pressed on the control panel, “LO” will be
displayed. To unlock the control, press the CONTROL
LOCK key for three seconds. The display will show “UL”
for one second.
Power Fail
The POWER FAIL indicator light informs you that due
to a power failure, the cabinet temperature exceeded
55°F (13°C). If the power failure lasted more than one
(1) hour, the display alternates between showing the
power failure duration (Hours and DURATION LED
illuminate in the display) and the cabinet temperature
(°F or °C illuminates) every ½ second. This safety
feature will aid in determining what food spoilage action
to take.
°F
Door Ajar
Indicator
Power Fail Indicator
Adjust DOWN Key
Adjust UP Key
Control Lock Key
Replace Air Filter
Indicator
Air Filter Reset Key Temp Mode Key Alarm Reset Key
Electronic Control Panel Layout
°F
HRS
HI-TEMP DURATION
°F
Setting Control Lock
Power Fail Indicator
Resetting Air Filter Alarm
Summary of Contents for Professional FPRH19D7LF
Page 17: ...17 MAJOR APPLIANCE WARRANTY ...