background image

7. 

GAS CONNECTION 

(Gas laundry centers only)

a. Remove the shipping cap from gas pipe at the rear of the
    dryer.

     NOTE: DO NOT 

connect the laundry center to L.P. gas service

     without converting the gas valve. An L.P. conversion kit (P/
    N 5303937053) must be installed by a qualified gas
    technician.
b. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved
    pipe from the gas supply line to the 3/8 inch (0.96 cm) pipe
    located on the back of the dryer. Use a 1/2 inch (1.27 cm) to
   3/8 inch (0.96 cm) reducer for the connection. Apply an
     approved thread sealer that is resistant to the corrosive action
    of liquefied gases on all pipe connections.
c. Open the shutoff valve in the gas supply line.
d. Test all connections by brushing on a soapy water solution.

NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME.

8. Form a “ U “ shape on the end of the drain hose with the
   hose pointed toward the drain. Place the formed end in a
    laundry tub or a standpipe and secure with a cable tie provided
   in the enclosure package. 

WATER WILL SYPHON FROM

  THE WASHER IF THE ABOVE INSTRUCTIONS ARE NOT
  FOLLOWED.

9. Remove the two (2) screws securing the dryer front access
    panel to the dryer cabinet. Lift the panel until the tabs can
    be disengaged from the cabinet. Remove the panel and set
    aside.

NOTE: 

A wiring diagram is located behind the dryer front

access panel.

REPLACEMENT PARTS

If replacement parts are needed for your laundry center, contact
the source where you purchased your laundry center.

                                                   

   Label all wires prior to disconnection when

servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.

                        Destroy the carton, plastic bags, and metal
band after the laundry center is unpacked. Children might use
them for play. Cartons covered with rugs, bedspreads, or plastic
sheets can become airtight chambers causing suffocation. Place
all materials in a garbage container or make materials
inaccessible to children.

                       The instructions in this manual and all other
literature included with this laundry center are not meant to
cover every possible condition and situation that may occur.
Good safe practice and caution 

MUST 

be applied when

installing, operating and maintaining any appliance.

Maximum benefits and enjoyment are achieved when all
the Safety and Operating instructions are understood and
practiced as a routine with your laundry tasks.

8

10. Connect the exhaust duct to outside duct work. Use duct
      tape to seal all joints.
11. Plug the power cord into a grounded outlet.

       NOTE: 

Check to ensure the power is off at a circuit breaker/

      fuse box before plugging the power cord into an outlet.
12.Turn on the power at a circuit breaker/fuse box.

13. Reinstall the dryer front access panel.
14. Run the washer and dryer though a cycle. Check for proper
      operation.

15. If your laundry center does not operate, please review the
     “Avoid Service Checklist” located in your Owner’s Guide
     before calling for service.
16. Place these instructions in a location near the laundry center
     for future reference.

On gas dryers, before the burner will light, it is
necessary for the gas line to be bled of air. If the
burner does not light within 45 seconds the first time
the dryer is turned on, the safety switch will shut
the burner off. If this happens, turn the timer to
“OFF” and wait 5 minutes before making another
attempt to light.

NOTE:

Access
Panel
Screws

Cable

Tie

                             Before operating the dryer, make sure
the dryer area is clear and free from combustible materials,
 gasoline, and other flammable vapors. Also see that nothing
(such as boxes, clothing, etc.) obstructs the flow of
 combustion and ventilation air.

:$51,1*

:$51,1*

Summary of Contents for GLET1142CS0

Page 1: ... for commercial applications such as restaurants or beauty salons etc For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light a...

Page 2: ... pounds per square inch maximum unbalance pressure hot vs cold 10 psi Your water department can advise you of your water pressure The hot water temperature should be about 140 degrees F DRAIN REQUIREMENTS 1 Drain capable of eliminating 17 gals per minute 2 A standpipe diameter of 1 1 4 inches 3 18 cm minimum 3 The standpipe height above the floor should be Minimum height 33 inches 83 82 cm Maximum...

Page 3: ...ate the duct outdoors and seal all joints with duct tape All male duct pipe fittings MUST be installed downstream with the flow of air Explosion hazard Do not install the laundry center where gasoline or other flammables are kept or stored If the laundry center is installed in a garage it must be a minimum of 18 inches 45 7 cm above the floor Failure to do so can result in death explosion fire or ...

Page 4: ...e Gas laundry center 3 Your laundry center needs the space around it for proper ventilation DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET WITH A SOLID DOOR 4 A minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for th...

Page 5: ...e the wire shipping clips securing the drain hose and power cord if equipped Plastic clamps secure the drain hose to the right side of the washer backsheet These clamps form a standpipe to prevent water syphoning DO NOT REMOVE THESE CLAMPS 6 Carefully move the laundry center to within 4 feet 1 22 m of the final location to begin the installation 5 25 IN 64 13 CM 3 IN 9 52 CM 4 13 16 IN 12 22 CM 9 ...

Page 6: ...akdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 If your laundry center is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances If in d...

Page 7: ...ard so the rear legs are off the ground Gently set the laundry center back down to allow the rear legs to self adjust Place a level on top of the washer Check it side to side then front to back Screw the front leveling legs up or down to ensure the laundry center is resting solid on all four legs no rocking of the laundry center should exist NOTE Keep the leg extension at a minimum to prevent exce...

Page 8: ...dren might use them for play Cartons covered with rugs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children The instructions in this manual and all other literature included with this laundry center are not meant to cover every possible condition and situation that may occur Good safe pra...

Reviews: