4
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
5.6 CAPACITY
Fig. 1
This shaded floor
area is for thru the
floor connection of
gas pipe stub and
shut-off valve.
Add 1/2” NPT 90°
black pipe elbow to
the gas supply pipe
stub and orient the
elbow as shown.
Fig. B
Fig. A
Fig. C
Install a flush mount
120V electrical wall
outlet in the shaded
area.
Installation with cabinets
Check location where the range will
be installed for proper electric and gas
supply, and stability of the floor.
The dimensions shown here
must be used and are minimal
unless otherwise stated. These
measurements do not allow for any
clearance below the cooking top or at
the rear of the range.
Contact surface must be solid and
level.
Things to remember:
• Do not seal the range to side
cabinets.
• Do not pinch the power supply
cord between the range and rear
wall.
• If cabinet depth is greater than
25”, the oven front frame must
extend beyond cabinet front by
1/2” minimum (See Fig. 1).
• All openings in the wall or floor
where the range is to be installed
must be sealed.
• The gas supply pipe stub and
elbow assembly centerline should
not exceed 4” height from the
floor.
Installation beside wall
If installing beside a wall, the minimum
distance to combustible wall on either side of
range above 36” height should be according
to the BTU of the largest burner (See Fig 2).
Fig. 2
* 9500 BTU or less
2”
10,000 - 16,999 BTU
3”
17,000 BTU or greater
5”
*
36±1/8”
(Adjustable)
46-5/8”
max
door
open
29-7/8”
25-3/4”
48-1/2”
max
30”
29-1/4”
max
door
closed
Fig. 3