![Frigidaire FKCH17F7HW Technical & Service Manual Download Page 22](http://html.mh-extra.com/html/frigidaire/fkch17f7hw/fkch17f7hw_technical-and-service-manual_115160022.webp)
Filter-Drier Installation
Any time the sealed system is opened and the
refrigerant charge is removed, the liquid line filter-drier
must be replaced and the system thoroughly evacuated
before replacing refrigerant.
1. Disconnect electrical supply to freezer.
2. Recover refrigerant by using EPA approved
recovery system.
3. Using a 3 cornered file, score a groove around
capillary tube as close to old filter-drier as possible.
Break capillary tube along score mark from
filter-drier.
4.
Cut condenser outlet tube at filter-drier. Discard
filter-drier.
5. Thoroughly clean condenser outlet tube and
capillary tube.
6. Place inlet connection of filter-drier over condenser
tube approximately ¼” and solder.
7.
Insert capillary tube input end into filter-drier outlet.
Do not allow tube to bottom against screen. Solder
carefully so that solder does not plug capillary tube.
8. Install process tube adapter to filter-drier.
9. Evacuate and charge system using the
recommended procedure described under
Evacuating and Recharging.
10. Reassemble unit.
3-8
Refrigeration System
Evaporator and Suction Line Replacement
1. Disconnect electrical supply to refrigerator.
2. Recover refrigerant by using EPA approved
recovery system.
3. Remove shelving.
4. Remove evaporator cover.
5. Remove evaporator from its installation position.
6. Cut or remove suction line from compressor.
7. Cut filter-drier from condensing unit.
8. Remove sealant from cabinet where suction line
enters.
9. Remove evaporator and suction line as one piece.
10. Install new evaporator with attached suction line.
11. Seal cabinet.
12. Install new filter drier at condenser outlet.
13. Evacuate and charge system using the
recommended procedure described under
Evacuating and Recharging.
DO NOT unbraze old filter-drier from system. This
will vaporize and drive moisture from desiccant
back into system. The old filter-drier should be
cut out of system.
The following instructions are generalized to
help the technician understand the procedures
of sealed system repairs. See Section 5
Component Teardown on the exact steps of
accessing the components of the refrigeration
system.
The following instructions are generalized to
help the technician understand the procedures
of sealed system repairs. See Section 5
Component Teardown on the exact steps of
accessing the components of the refrigeration
system.
Summary of Contents for FKCH17F7HW
Page 2: ......
Page 3: ...Basic Information 1 1 Section 1 Basic Information ...
Page 9: ...Electronic Control 2 1 Section 2 Electronic Control ...
Page 14: ...2 6 Electronic Control Notes ...
Page 15: ...3 1 Refrigeration System Section 3 Refrigeration System ...
Page 30: ...3 16 Refrigeration System HFC 134a CFC 12 Pressure Temperature Chart ...
Page 33: ...4 1 Component Teardown Section 4 Component Teardown ...
Page 47: ...5 1 Troubleshooting Section 5 Troubleshooting ...
Page 52: ...5 6 Troubleshooting Notes ...
Page 53: ...6 1 Wiring Diagrams Section 6 Wiring Diagrams ...
Page 54: ...6 2 Wiring Diagrams 7 4 6 2 8 3 5 1 ...
Page 56: ...7 1 Section 7 Installation Information Installation Information ...
Page 62: ...7 7 Installation Information Model FKCH17F7HW Unit Dimensions ...