VENTILATION SYSTEM REQUIREMENTS

Air flow (ventilation) through the dryer is critical

 

in the ability of

the dryer to function properly. Heat and air are required to dry
clothes. Heat provides energy to evaporate the moisture in the
clothes. Air is used to carry the heat to the clothes load and
exhaust the evaporated moisture outside. Without adequate air
flow, the heated air can not get to the clothes and they won’t
dry. There are two major components in providing the dryer
with adequate air flow: supply air and an exhaust system. If
either of these are severely restricted, the function of the dryer
will be reduced and in some cases lead to gases building up in
the residence to a dangerous level. Also, the better the air flow,
the better the drying performance and increased longevity of
the appliance.

SUPPLY OF MAKEUP AIR

Air that is drawn through the dryer and exhausted outside must
be replaced in the dwelling.  The replacement air is known as
make-up air. Make up air is required for all types of household
devices, like furnaces, water heaters, clothes dryers, ranges,
kitchen and bathroom exhaust fans, and fireplaces.
If the dwelling is not properly ventilated, such as in a tightly
constructed house, there may not be enough make up air. If this
condition exists, gases that would normally be vented outside
will be slowed and could build up in the dwelling.  Gases will
include carbon monoxide produced during combustion in
appliances such as in furnaces, water heaters, ranges, dryers
and fire places.
To insure the proper amount of make up air follow: ANZI 223.1
section 8.3.1.5:   - “Make up air requirements for the operation of
exhaust fans, kitchen ventilation systems, clothes dryers, and
fireplaces shall be considered in determining the adequacy of a
space to provide air requirements” or Canadian Natural Gas and
Propane Code.

 

– 

Improper ventilation could lead to a build up

of gases and a high concentration of carbon monoxide.

 

– Improper ventilation could starve the dryer of

make up air and could create a fire hazard as well as increase
drying times

 

Do not use plastic flexible duct to exhaust the dryer.

Excessive lint can build up inside exhaust system and create a fire
hazard and restrict air flow. Restricted air flow will increase dryer
times. If your present system is made up of plastic duct or metal
foil duct, 

replace it

 with a rigid or flexible metal duct. 

Ensure the

present duct is free of any lint prior to installing dryer duct.

 

If the dryer is not exhausted outdoors, some fine lint will be

expelled into the laundry area. 

An accumulation of lint in any

area of the home can create a health and fire hazard. 

The dryer

exhaust system MUST be exhausted to the outside of the
dwelling!

 

Do not allow combustible materials (for example: clothing,

draperies/curtains, paper) to come in contact with exhaust
system. 

The dryer 

MUST NOT

 be exhausted into a chimney, a

wall, a ceiling, or any concealed space of a building which can
accumulate lint, resulting in a fire hazard.

 Exceeding the length of duct pipe or number of elbows

allowed in the "MAXIMUM LENGTH" charts 

can cause an

accumulation of lint in the exhaust system.  Plugging the system
could create a fire hazard, as well as increase drying times.

 

Do not screen the exhaust ends of the vent system, nor use

any screws or rivets to assemble the exhaust system.

 Lint can

become caught in the screen, on the screws or rivets, clogging
the duct work and creating a fire hazard as well as increasing
drying times. Use an approved vent hood to terminate the duct
outdoors, and seal all joints with duct tape. All male duct pipe
fittings 

MUST

 be installed downstream with the flow of air.

 

Explosion hazard. Do not install the dryer where

gasoline or other flammables are kept or stored.

 If the dryer is

installed in a garage, it must be a minimum of 18 inches (45.7 cm)
above the floor. Failure to do so can result in death, explosion,
fire or burns.

In installations where the exhaust system is not described in the
following charts, the following method must be used to determine
if the exhaust system is acceptable:
1.

Connect an inclined or digital manometer between the dryer
and the point the exhaust connects to the dryer.

2.

Set the dryer timer and temperature to air fluff (cool down)
and start the dryer.

3.

Read the measurement on the manometer.

4.

The system back pressure 

MUST NOT

 be higher than 0.75

inches of water column. If the system back pressure is less
than 0.75 inches of water column, the system is acceptable. If
the manometer reading is higher than 0.75 inches of water
column, the system is too restrictive and the installation is
unacceptable.

EXHAUST SYSTEM REQUIREMENTS

Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible

metal 

duct and approved vent hood which has a swing-out

damper(s) that open when the dryer is in operation. When the
dryer stops, the dampers automatically close to prevent drafts
and the entrance of insects and rodents. To avoid restricting the
outlet, maintain a minimum of 12 inches (30.5 cm) clearance
between the vent hood and the ground or any other obstruction.

 The following are specific requirements for

proper and safe operation of your dryer. Failure to follow these
instructions can create excessive drying times and fire
hazards.

Summary of Contents for FGQBB30DS0

Page 1: ... designed under ANSI Z 21 5 1 or ANSI UL 2158 CAN CSA C22 2 latest editions for HOME USE only This Dryer is not recommended for commercial applications such as restaurants or beauty salons etc Pre Installation Requirements 2 Electrical Requirements 2 VentilationSystemRequirements 3 4 ExhaustSystemRequirements 4 GasSupplyRequirements 4 LocationofYourDryer 5 MobileHomeInstallation 6 Rough InDimensio...

Page 2: ...tors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS for additional instructions OUTLET RECEPTACLE NEMA 10 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GAS Dryer CIRCUIT Individual 15 amp branch circuit fused with a 15 amp maximum...

Page 3: ...edryerisnotexhaustedoutdoors somefinelintwillbe expelledintothelaundryarea Anaccumulationoflintinany areaofthehomecancreateahealthandfirehazard Thedryer exhaustsystemMUSTbeexhaustedtotheoutsideofthe dwelling Donotallowcombustiblematerials forexample clothing draperies curtains paper tocomeincontactwithexhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed s...

Page 4: ...low flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve 5 A 1 8 inch 0 32 cm N P T plugged tapping accessible for test gauge connection MUST be installed immediately upstream of the gas supply connection to the dryer 6 The dryer MUST be di...

Page 5: ... dryer 3 Your dryer needs the space around it for proper ventilation DONOTinstallyourdryerinaclosetwithasoliddoor 4 Aminimumof120squareinches 774 2squarecm ofopening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length of the door is acceptable Closet door...

Page 6: ...d 2 If dryer is exhausted through the floor and area beneath the mobile home is enclosed the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This d...

Page 7: ...d a plastic knife to help pull out the plugs Be careful not to scratch the paint 2 Remove the four screws that secure the door hinges to the dryer front panel see below NOTE Remove one screw from each of the two hinges first Hold the door firmly before removing the last two screws 3 Rotate the door 180 and reinstall the door hinges to the dryer front panel with the four screws 4 Install the four h...

Page 8: ...resulting in electrical shock Do not use an aluminum wired receptacle with a copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 2...

Page 9: ... the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp power cord NEMA 10 30 type SRDT through the strain relief 4 Attach the power cord neutral center wire conductor to t...

Page 10: ...h as boxes clothing etc obstructs the flowofcombustionandventilationair 5 Run the dryer through a and cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer to OFF ...

Page 11: ...erdo con la norma ANSI Z 21 5 1 o ANSI UL 2158 CAN CSA C22 2 las últimas ediciónes Esta secadora no se recomienda para uso commercial tal como en restaurantes salones de belleza etc P N 134306200B 0404 Requerimientos de instalación preliminares 2 Requerimientos eléctricos 2 Requerimientos del sistema de ventilación 3 4 Requerimientos del suministro de gas 4 Ubicación de su secadora 4 5 Instalación...

Page 12: ...eso en los EE UU NOTA No saque por ningún motivo la espiga de puesta a tierra del enchufe ESPIGA DE PUESTA A TIERRA ALIMENTACIÓN ELÉCTRICA Corriente alterna monofásica 60 Hz 240 voltios trifilar o tetrafilar CORDÓN ELÉCTRICO En la secadora se DEBE usar un cordón eléctrico trifilar NEMA 10 30 tipo SRDT para un voltaje nominal mínimo de 240 voltios CA 30 amp con 3 conectores de horquillas con termin...

Page 13: ... para la salud y un riesgo de incendio El sistema de escape de la secadora DEBE estar dirigido hacia el exterior de la vivienda Nopermitaquelosmaterialescombustibles porejemplo laropa cortinas cortinajes papel tengancontactoconlos ductos El escape de la secadora NO DEBE dirigirse hacia el interior de una chimenea hacia una pared hacia el cielo raso o hacia cualquier otro espacio reducido del edifi...

Page 14: ...ulgada 2 54 cm REQUERIMIENTOS DEL SUMINISTRO DE GAS REQUERIMIENTOS DEL SUMINISTRO DE GAS REQUERIMIENTOS DEL SUMINISTRO DE GAS REQUERIMIENTOS DEL SUMINISTRO DE GAS REQUERIMIENTOS DEL SUMINISTRO DE GAS Reemplace la tubería de conexión de cobrequenoestárecubridacon plástico El latóninoxidableo recubridoconplásticoDEBESERutilizado 1 La instalación DEBE hacerse cumplir con los códigos locales o en ause...

Page 15: ... 387 1 cm 387 1 cm 387 1 cm 387 1 cm 387 1 cm2 2 2 2 2 PUER PUER PUER PUER PUERT T T T TA DEL ARMARIO A DEL ARMARIO A DEL ARMARIO A DEL ARMARIO A DEL ARMARIO 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 15 38 1 cm 15 38 1 cm 15 38 1 cm 15 38 1 cm 15 38 1 cm 1 2 54 cm 1 2 54 cm 1 2 54 cm 1 2 54 cm 1 2 54 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 INSTALACIÓNDENTRODEUNNICHOO...

Page 16: ...a casa móvil es cerrada el ducto de escape DEBE terminar fuera del recinto con el extremo final asegurado en contra de la estructura de la casa móvil 3 Al instalar una secadora de gas en una casa móvil hay que instalar una provisión de aire fresco suplementario La provisión tiene que ser más grande que dos veces el espacio del escape de la secadora 4 Esta secadora DEBE asegurarse al piso El juego ...

Page 17: ... ha sido diseñada para que la puerta pueda ser cambiada de lado en cualquier momento sin necesidad de piezas adicionales La conversión se hace transfiriendo las bisagras al lado opuesto del gabinete Cómo cambiar la dirección de apertura de la puerta 1 Abra la puerta de la secadora Quite los cuatro receptores del agujero de la bisagra del lado izquierdo de la apertura de la puerta Colóquelos en un ...

Page 18: ...dicados en este manual para el cordón eléctrico que debe ser adquirido Se debe instalar un anclaje aprobado por el U L para el cordón eléctrico Si no se utiliza un anclaje para sujetar el cordón eléctrico éste puede salirse de la secadora y cortarse con cualquier movimiento resultando en un choque eléctrico No utilice un tomacorriente con cables de aluminio con un cordón y un enchufe de cobre o vi...

Page 19: ...cable en la parte trasera de la secadora con dos tornillos Apriete firmemente los tornillos 7 Apriete firmemente los tornillos del anclaje de cable contra el cordón eléctrico 8 Apriete la tuerca del anclaje de cable a fin de que el anclaje no gire 9 Coloque nuevamente la cubierta del tablero de bornes CABLE DE PUESTA A TIERRA NEUTRAL ROJO NEGRO BLANCO TUERCA SOPORTE DE MONTAJE DEL ANCLAJE DE CABLE...

Page 20: ...as las situaciones o condiciones posibles que puedan presentarse Por lo tanto se DEBEN seguir prácticas seguras y tener cuidado cuando se instala pone en funcionamiento y mantiene cualquier artefacto doméstico CONEXIÓN DEL GAS 1 Saque la tapa de embarque de la tubería de gas de la secadora situada en la parte trasera NOTA NO conecte la secadora al suministro de propano sin convertìr la válvula del...

Reviews: