ENGLISH
– 4
Typical Under Counter Installation of an Electric Built-in Oven
with a Cooktop Mounted Above
This cooktop may be installed over certain
built-in electric oven models.
Approx. 3”
G
F
E
36” Min.
Use 3/4” plywood, installed on two
runners, flush with toe plate. Must be
capable of supporting 150 lbs.
Cut an opening in wood base
minimum 9” x 9”, 2” from left
side filler panel, to route
armoured cable to junction box.
4 1/2” Max.*
* If no cooktop is installed directly over
the oven unit, 5” maximum is allowed.
Anti-tip brackets must
be used to secure the
built-in oven to the
cabinets.
CUTOUT DIMENSIONS (inches)
BUILT-IN OVEN SIZE
E
F
G
30”
28 1/4” - 28 7/8”
28 1/2” - 29”
24”
27”
28 1/8” - 28 7/8”
24 7/8” - 25 1/4”
23 1/2”
Side filler panels are necessary to
isolate the unit from adjoining
cabinets. Panel height should allow
for installation of approved cooktop
models. See “Typical Gas Cooktop
Installation Over an Electric Built-in
Oven Installed Under the Counter”
on the page 3.
208/240 Volt grounded
junction box for built-in oven.