background image

Important Safety Instructions

3

2009 Electrolux Home Products, Inc.

All rights reserved.

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Unit must be upright for one hour prior to operating.

Plug in &

press RESET

The power supply cord contains a current device that senses damage to the power cord. To test 

your power supply cord do the following:

Plug in the Air Conditioner.
The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will

notice a click as the RESET button pops out.
Press the RESET button. Again you will notice a click as the button engages.

The power supply cord is now supplying electricity to the unit. (This is also indicated by a light

on the plug head).

NOTE:

Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,

or it cannot be reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained

from the product manufacturer.

SAFETY PRECAUTIONS

Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make 

units run excessively.

Do not climb on or place objects on outdoor part of the unit.

Do not hang objects off the unit.

Do not place containers with liquids on the unit.

Turn off the air conditioner at the power source when it will not be used for an extended period of time.

Periodically check the condition of the unit’s installation accessories for any damage.

Do not apply heavy pressure to the radiator fins of the unit.

Operate the unit with air filter in place.

Do not block or cover the intake grille, discharge area and outlet ports.

Ensure that any electrical/electronic equipment is one yard away from the unit.

Do not use or store flammable gases near the unit. 

Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.

Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.

When cleaning the unit, first make sure that the power and circuit breaker are turned off.

CAUTION!  Avoid Injury or damage to the unit or other property 

Summary of Contents for FFRE0633S14

Page 1: ... the Use Care Care and Cleaning 11 Energy Saving Ideas 11 16120300A04629 June 2009 Product Registration 4 Packaging 4 Normal Sounds 4 Air Conditioner Features 5 Important Safety Instructions 2 3 Operating Instructions 5 10 of your Room Air Conditioner Before You Call 12 Major Appliance Limited Warranty 13 ...

Page 2: ...o use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric sho...

Page 3: ...laced by one obtained from the product manufacturer SAFETY PRECAUTIONS Provide occasional ventilation during use Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively Do not climb on or place objects on outdoor part of the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the air c...

Page 4: ...r incorrect installation Vibration Pinging or Swishing Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration 4 Product Registration Packaging Normal Sounds 2009 Electrolux Home Products Inc All rights rese...

Page 5: ... Operating Instructions ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPERATURE TIME SETS FAN SPEED SETS MODE TURNS UNIT ON OR OFF ACTIVATES TIMER CHECK FILTER RESET BUTTON SLEEP MODE REMOTE TEMP SENSING INDICATOR some models CLEAN AIR FEATURE some models Battery Size AAA Warning Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries w DISPLAY R...

Page 6: ...rns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually 2009 Electrolux Home Products Inc All rights reserved YOU WILL SEE PRESS TO RAISE PRESS TO LOWER DO THIS Note Tap or hold either up or down button until the desired temperature is seen on the display This tempe rature will be automatically maintained anywhere between 60 F 16 C and ...

Page 7: ... continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by again pressing the Sleep button SLEEP FEATURE DO THIS PRESS SLEEP BUTTON YOU WILL SEE Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed du...

Page 8: ...p to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start Operation automatically selects cooling with maximum Fan speed if Cool Energy Saver or Fan Only was the last mode selected The temperature maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the ...

Page 9: ... will beep to indicate the remote sensing mode has ended The display on the remote control indicates the temperature at the remote ONLY NOTE The Remote Sensing function is terminated either by using the Remote Sensing Stop button or the main ON OFF button on the unit 9 Operating Instructions Operating Instructions continued 2009 Electrolux Home Products Inc All rights reserved TO CHANGE TEMPERATUR...

Page 10: ...red Fresh Air Vent Control on some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Fresh Air see Fig 2 3 Exchange air from the room Vent Open see Fig 3 Figure 1 VENT CLOSED Figure 2 FRESH AIR Figure 3 VENT OPEN TO TURN UNIT OFF YOU WILL SEE DO THIS PRESS ON OFF BUTTON 8 WAY Air Directional Louvers Air directional...

Page 11: ...checked at least once a month to see if cleaning is necessary Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils Grasp the filter by the center and pull up and out Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or i...

Page 12: ...oil set to FAN ONLY mode Then set temperature to a higher setting 12 Room temperature below 60 F 16 C Cooling may not occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold coil located behind air filter Straighten away from coil Air from unit does not feel cold enough Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor...

Page 13: ...IS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servi...