INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

Check ignition of oven burners.

The operation of oven igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power. Be sure all packing materials and
literature are removed from oven.

The oven burner is equipped with an electric control
system as well as an electric oven burner igniter. If your
model is equipped with an upper oven burner, it will also
have an electric burner igniter. These control systems
require no adjustment. When the oven is set to operate,
current will flow to the igniter. It will "glow" similar to a light
bulb. When the igniter has reached a temperature sufficient
to ignite gas, the electrically controlled oven valve will open
and flame will appear at the oven burner. There is a time
lapse from 30 to 60 seconds after the thermostat is turned
ON before the flame appears at the oven burner. When the
oven reaches the set temperature, the glowing igniter will
cycle off. The burner flame will turn off in 20 to 30 seconds
after the igniter turns off. To maintain any set oven
temperature, this cycle will continue as long as the oven
control is set to operate.

To check oven burner ignition:

a.

Set oven to 

Bake

 

at 300ºF

. See User's Manual for

operating instructions.

b.

Within 60 seconds the oven burner should ignite.
Check for proper flame, and allow the burner to cycle
once. Reset control to 

OFF

.

c.

If your model is equipped with a waist-high broiler, set
oven to

 Broil

. See User's Manual for operating

instructions.

d.

Within 60 seconds the broil burner should ignite.
Check for proper flame. Reset control to

 OFF

.

Burner flame size

5/8"

Cooktop

Check ignition of surface
burners.

Operation of electric igniters should be checked after range
and supply line connectors have been carefully checked for
leaks and range has been connected to electric power.

a.

To check for proper ignition, 

push in and turn

 a

surface burner knob 

counterclockwise

 to the 

LITE

position. You will hear the igniter sparking.

b.

The surface burner should ignite when gas is available
to the burner. Purge air from supply lines by leaving
knob in the 

LITE

 position until burner ignites. Each

burner should light within four (4) seconds in normal
operation after air has been purged from supply lines.

c.

Visually check that burner has a flame. Once the
burner ignites, the control knob should be turned out
of the LITE position.

d.

Try each surface control knob separately until all
surface burners have been checked. Each burner
location is equipped with a separate electrode.

Adjust the LOW setting of surface
burner valves (linear flow).

Test  to verify if LOW setting should be adjusted:

a.

Push in and turn control to LITE until burner ignites.

b.

Push in and quickly turn knob to lowest position.

c.

If burner goes out, reset control to OFF.

d.

Remove the surface burner control knob.

For all burner styles (except Dual or Twin burner):

e.

Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size
can be increased or decreased with the turn of the
screw. Turn counterclockwise to increase flame size.
Turn clockwise to decrease flame size. (See Figs. 17
& 19).

Adjust flame until you can quickly turn knob from LITE
to lowest position without extinguishing the flame.
Flame should be as small as possible without
extinguishing.

For Dual or Twin burner style adjustment only:

e.

The inner portion (Simmer) of the twin burner flame
size can be increased or decreased with the turn of
screw A. Use screw B to adjust the flame size of the
outer portion of the Twin Burner (See Fig. 18). Turn
the screw counterclockwise to increase flame size.
Turn clockwise to decrease flame size. Adjust flame
size until you can quickly turn the knob from LITE to
lowest position without extinguishing the flame.

Note: Air mixture adjustments are not required on surface

burners.

for Dual or Twin burner only

other surface burners

A

B

Fig. 17

Fig. 19

7

8

9

Fig. 18

Summary of Contents for FFGF3021ZW

Page 1: ...ge Remove all packing material from the oven compartments before connecting the gas and electrical supply to the range Observe all governing codes and ordinances Be sure to leave these instructions with the consumer Important notes to the consumer Keep these instructions with your Use Care Guide for future reference Be sure your range is installed and grounded properly by a qualified installer or ...

Page 2: ...ER FAILURE RESET ALL OVEN CONTROLS TO OFF IN THE EVENT OF A POWER FAILURE The electric ignitor will automatically re ignite the oven burner when power resumes if the oven thermostat control was left in the ON position When an electrical power failure occurs during use the surface burners will continue to operate During a power outage the surface burners can be lit with a match Hold a lighted match...

Page 3: ...rials you will need Pipe joint sealant that resists action of LP Propane gas Fig h Gas line manual shut off valve Fig i A new flexible metal appliance conduit 1 2 NPT x 3 4 or 1 2 I D must be design certified by CSA International Because solid pipe restricts moving the range we recommend using a new flexible conduit 4 to 5 foot length for each new installation and additional reinstallations Fig j ...

Page 4: ...in the wall or floor where the range is to be installed must be sealed 2 7 Recommended area for 120V outlet on rear of wall and area for thru the wall connection of pipe stub and shut off valve 18 Min to cabinets on either side of range 30 30 Min height from cooktop to cabinets 25 24 15 23 36 Std 30 11 1 2 Installation beside wall If installing beside a wall the minimum distance to combustible wal...

Page 5: ...alled and does not allow the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 4 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4...

Page 6: ...re regulator to LP Propane use Care must be taken during installation of range not to obstruct the flow of combustion and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Example If regulator is set for natura...

Page 7: ...east two 2 other top burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for Natural Gas the manifold pressure is 4 For LP Propane Gas the manifold pressure is 10 c Tighten the gas supply fitting and or appliance conduit to flare union adaptor on the ri...

Page 8: ...er cap placement Fig 14 Incorrect burner cap placement Fig 15 Check burner cap placement It is very important to be sure that all surface burner caps and burner grates are properly installed and in the correct locations before operating the appliance Please note that the burner heads are secured to the cooktop The cooktop is not removeable Do not attempt to remove or lift the cooktop To prevent fl...

Page 9: ...to electric power a To check for proper ignition push in and turn a surface burner knob counterclockwise to the LITE position You will hear the igniter sparking b The surface burner should ignite when gas is available to the burner Purge air from supply lines by leaving knob in the LITE position until burner ignites Each burner should light within four 4 seconds in normal operation after air has b...

Page 10: ... about your range always be sure to include the model and serial numbers and a lot number or letter from the identification plate on your range Your identification plate also tells you the rating of the burners the type of fuel and the pressure the range was adjusted for when it left the factory Adjust air shutter lower oven To determine if the oven burner flame is proper remove the oven bottom pa...