INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

Installation with cabinets

Check location where the range will
be installed for proper electric and
gas supply, and stability of the floor.

The dimensions shown here must
be used and are minimal unless
otherwise stated. These
measurements do not allow for any
clearance below the cooking top or
at the rear of the range.

Contact surface must be solid and
level.

Things to remember:

Do not seal the range to side
cabinets.

Do not pinch the power supply
cord between the range and
rear wall.

If cabinet depth is greater than
25”, the oven front frame must
extend beyond cabinet front by
1/2” minimum (See Fig. 1).

All openings in the wall or floor
where the range is to be
installed must be sealed.

2”

7”

Recommended
area for 120V
outlet on rear of
wall and area for
thru the wall
connection of pipe
stub and shut-off
valve.

18”

Min. to cabinets on

either side of range

30”

30”

Min. height from

cooktop to cabinets

25”

24”

*15”

23”

36”

Std.

30”

11-1/2”

Installation beside wall

If installing beside a wall, the
minimum distance to combustible
wall on either side of range above
36" height should be according to
the BTU of the largest burner (See
Fig 2).

36±1/8”

(Adjustable)

46-5/8”

max

door

open

29-7/8”

25-3/4”

48-1/2”
max

30”

29-1/4”

max

door

closed

Fig. 1

Fig. 3

Fig. 2

10-1/2”

13”

Max.

Recommended area for thru
the floor connection of gas
pipe stub and shut-off valve.

* 9500 BTU or less

2"

  10,000 - 16,999 BTU

3"

  17,000 BTU or greater

5"

*

* Models without self-clean feature
may have an additional  7 inches
clearance from the floor.

Summary of Contents for FFGF3021ZW

Page 1: ...ge Remove all packing material from the oven compartments before connecting the gas and electrical supply to the range Observe all governing codes and ordinances Be sure to leave these instructions with the consumer Important notes to the consumer Keep these instructions with your Use Care Guide for future reference Be sure your range is installed and grounded properly by a qualified installer or ...

Page 2: ...ER FAILURE RESET ALL OVEN CONTROLS TO OFF IN THE EVENT OF A POWER FAILURE The electric ignitor will automatically re ignite the oven burner when power resumes if the oven thermostat control was left in the ON position When an electrical power failure occurs during use the surface burners will continue to operate During a power outage the surface burners can be lit with a match Hold a lighted match...

Page 3: ...rials you will need Pipe joint sealant that resists action of LP Propane gas Fig h Gas line manual shut off valve Fig i A new flexible metal appliance conduit 1 2 NPT x 3 4 or 1 2 I D must be design certified by CSA International Because solid pipe restricts moving the range we recommend using a new flexible conduit 4 to 5 foot length for each new installation and additional reinstallations Fig j ...

Page 4: ...in the wall or floor where the range is to be installed must be sealed 2 7 Recommended area for 120V outlet on rear of wall and area for thru the wall connection of pipe stub and shut off valve 18 Min to cabinets on either side of range 30 30 Min height from cooktop to cabinets 25 24 15 23 36 Std 30 11 1 2 Installation beside wall If installing beside a wall the minimum distance to combustible wal...

Page 5: ...alled and does not allow the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 4 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4...

Page 6: ...re regulator to LP Propane use Care must be taken during installation of range not to obstruct the flow of combustion and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Example If regulator is set for natura...

Page 7: ...east two 2 other top burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for Natural Gas the manifold pressure is 4 For LP Propane Gas the manifold pressure is 10 c Tighten the gas supply fitting and or appliance conduit to flare union adaptor on the ri...

Page 8: ...er cap placement Fig 14 Incorrect burner cap placement Fig 15 Check burner cap placement It is very important to be sure that all surface burner caps and burner grates are properly installed and in the correct locations before operating the appliance Please note that the burner heads are secured to the cooktop The cooktop is not removeable Do not attempt to remove or lift the cooktop To prevent fl...

Page 9: ...to electric power a To check for proper ignition push in and turn a surface burner knob counterclockwise to the LITE position You will hear the igniter sparking b The surface burner should ignite when gas is available to the burner Purge air from supply lines by leaving knob in the LITE position until burner ignites Each burner should light within four 4 seconds in normal operation after air has b...

Page 10: ... about your range always be sure to include the model and serial numbers and a lot number or letter from the identification plate on your range Your identification plate also tells you the rating of the burners the type of fuel and the pressure the range was adjusted for when it left the factory Adjust air shutter lower oven To determine if the oven burner flame is proper remove the oven bottom pa...

Reviews: