INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

Checking manifold gas pressure

  

Do not use flame to check for gas leaks.

Disconnect the range and its individual shut-off valve from
the gas supply piping system during any pressure testing of
that system at test pressures greater than 14" of water
column pressure (approximately 1/2" psig).

The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column
pressure (approximately 1/2" psig).

If it should be necessary to check the manifold gas
pressure, connect manometer (water gauge) or other
pressure device to the top burner right rear orifice.  Using a
rubber hose with inside diameter of approximately 1/4," hold
tubing down tight over orifice.  Turn burner valve on.

For an accurate pressure check have at least two (2) other
top burners burning. Be sure the gas supply (inlet) pressure
is at least one inch above specified range manifold
pressure. The gas supply pressure should never be over 14"
water column. When properly adjusted for Natural Gas the
manifold pressure is 4". For LP/Propane Gas the manifold
pressure is 10".

c.

Tighten the gas supply fitting and/or appliance conduit
to flare union adaptor on the right side of the pressure
regulator  (refer to Fig. 10) using 

NO MORE THAN

15ft./lbs.

 of torque. Be sure to 

stabilize

 the 1/2" flare

union adapter with an adjustable wrench before
tightening  the gas supply fitting and/or appliance
conduit.

d.

Install flare union adapter to external manual shut-off
valve (See Fig. 8).

e.

Attach flexible appliance conduit to flare union adaptor
on shut-off valve (See Fig. 8).

f.

Make sure the 

service shut-off valve on pressure

regulator is set to the ON position 

(See Fig. 11).

 Fig. 10

g.

Check for gas leaks. Turn the gas supply on to the
range and use a liquid leak detector at all joints and
conduits to check for leaks in the system.

Fig. 11

Pressure
regulator

Service shut-off

valve (shown in

ON position)

Summary of Contents for FFGF3021ZW

Page 1: ...ge Remove all packing material from the oven compartments before connecting the gas and electrical supply to the range Observe all governing codes and ordinances Be sure to leave these instructions with the consumer Important notes to the consumer Keep these instructions with your Use Care Guide for future reference Be sure your range is installed and grounded properly by a qualified installer or ...

Page 2: ...ER FAILURE RESET ALL OVEN CONTROLS TO OFF IN THE EVENT OF A POWER FAILURE The electric ignitor will automatically re ignite the oven burner when power resumes if the oven thermostat control was left in the ON position When an electrical power failure occurs during use the surface burners will continue to operate During a power outage the surface burners can be lit with a match Hold a lighted match...

Page 3: ...rials you will need Pipe joint sealant that resists action of LP Propane gas Fig h Gas line manual shut off valve Fig i A new flexible metal appliance conduit 1 2 NPT x 3 4 or 1 2 I D must be design certified by CSA International Because solid pipe restricts moving the range we recommend using a new flexible conduit 4 to 5 foot length for each new installation and additional reinstallations Fig j ...

Page 4: ...in the wall or floor where the range is to be installed must be sealed 2 7 Recommended area for 120V outlet on rear of wall and area for thru the wall connection of pipe stub and shut off valve 18 Min to cabinets on either side of range 30 30 Min height from cooktop to cabinets 25 24 15 23 36 Std 30 11 1 2 Installation beside wall If installing beside a wall the minimum distance to combustible wal...

Page 5: ...alled and does not allow the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 4 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4...

Page 6: ...re regulator to LP Propane use Care must be taken during installation of range not to obstruct the flow of combustion and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Example If regulator is set for natura...

Page 7: ...east two 2 other top burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for Natural Gas the manifold pressure is 4 For LP Propane Gas the manifold pressure is 10 c Tighten the gas supply fitting and or appliance conduit to flare union adaptor on the ri...

Page 8: ...er cap placement Fig 14 Incorrect burner cap placement Fig 15 Check burner cap placement It is very important to be sure that all surface burner caps and burner grates are properly installed and in the correct locations before operating the appliance Please note that the burner heads are secured to the cooktop The cooktop is not removeable Do not attempt to remove or lift the cooktop To prevent fl...

Page 9: ...to electric power a To check for proper ignition push in and turn a surface burner knob counterclockwise to the LITE position You will hear the igniter sparking b The surface burner should ignite when gas is available to the burner Purge air from supply lines by leaving knob in the LITE position until burner ignites Each burner should light within four 4 seconds in normal operation after air has b...

Page 10: ... about your range always be sure to include the model and serial numbers and a lot number or letter from the identification plate on your range Your identification plate also tells you the rating of the burners the type of fuel and the pressure the range was adjusted for when it left the factory Adjust air shutter lower oven To determine if the oven burner flame is proper remove the oven bottom pa...