background image

Outdoor  Unit

4

OUTLET

INLET

CONNECTING PIPING
AND ELECTRICAL WIRING

DRAIN HOSE

4

Loading of the battery

1

2

3

4

Remove the battery cover;

Load the batteries as illustrated. 

2 R-03 batteries, resetting key 

(cylinder);

Be sure that the loading

is in line with th

e" + "/"-";

Load the battery,then put on the cover again.

 The distance between the signal transmission head and the rece-

iver hole should be within 7m without any obstacle as well.

When electronic-started type fluorescent lamp or change- over

wireless telephone is installed in the 

ver is apt to be disturbed in receiving the signals,

so the distance to the indoor unit should be shorter.

type fluorescent lamp or

room, the recei

Note:

Full display or unclear display during operation indicates the 

ries have been used up. Please change batteries.

If the remote controller can't run normally during operation, please 

reload several minutes later.

batte

remove the batteries and

Parts and Functions

Remote controller

If the unit which you purchased has healthy function,follow it.If not,please ignore.

NOTE:

Cooling only unit do not have  displays and functions related with heating

Indoor Unit

1. Mode display

2. Signal sending display

4. FAN SPEED display

5. LOCK display

6. TIMER OFF display

TIMER ON display

7. TEMP display

16. LOCK button

Used to lock buttons and LCD display

25. RESET button

When the remote controller appears

abnormal, use a sharp pointed

article to press this button to reset

22. HOUR button

Control the lightening and 

extinguishing of the indoor LED 

display board.

8. 

9. QUIET button

11. COOL button

10. HEAT button

12. AUTO button

13. FAN SPEED button

14. TIMER button

15. HEALTH button

17. LIGHT button

18. POWER ON/OFF button

19. DRY button

20. TEMP button

21. SWING button

23. EXTRA FUNCTION button

24.CANCEL/CONFIRM button

Function: Setting and cancel to the 

timer and other additional functions.

3. SWING  display

Operation mode

AUTO

FAN

COOL DRY

Remote controller

HEAT

LO

MED

HI

AUTO

Display 

circulated

the remote.

Additional functions display

1

2

3
4
5
9

10

11

12

13

14
15

16
17

8

22

23

24

25

19
20

21

18

7

6

Operation mode

Remote controller

QUIET

TURBO

SLEEP

Supplemented 

    electrical 

     heating

HEALTH

Function: Sleeping---- Healthy
airflow position1--- Healthy airflow
position 2 ---  TURBO  ---  

Air sending ---   A-B yard

Actual inlet grille may vary from the one shown in the 

manual according to the product purchased

1

Display board

(adjust left and 

ow)

Vertical blade

right air fl

Air Purifying Filter

Inlet

(inside)

Emergency

 Switch

Horizontal flap

(adjust up and down air flow

  Don't adjust it manually)

Outlet

Inlet grille

Display board

1

4

2

3

5

 

Signal receiver hole

 

 

ON/OFF  display

4

2

3

1

5

TIMER ON\OFF display

SLEEP display

 Ambient temp.display

When receiving the remote

control signal, display the set 

displayed.

time the room temperature is 

temperature and in the rest

Note to the power failure resume:

press the sleep button ten times in five seconds

and enter function after hearing four sounds.And

press the sleep button ten times within five

seconds and leave this function after hearing

TIMER ON-OFF display

COOL\HEAT\Dry\

AUTO display

 two sounds.

Summary of Contents for FATC18FNVWHC

Page 1: ...or future reference 0010571257 Made in Thailand 9 1 2 8 5 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING FATP24FNVWHE FATP24FNVWHC FATC28FNVWHE FATC28FNVWHC FATP28FNVWHE FATP28FNVWHC FATC18FNVWHE FATC18FNVWHC FATP18FNVWHE FATP18FNVWHC FATC24FNVWHE FATC24FNVWHC ...

Page 2: ...button Control the lightening and extinguishing of the indoor LED display board 8 9 QUIET button 11 COOL button 10 HEAT button 12 AUTO button 13 FAN SPEED button 14 TIMER button 15 HEALTH button 17 LIGHT button 18 POWER ON OFF button 19 DRY button 20 TEMP button 21 SWING button 23 EXTRA FUNCTION button 24 CANCEL CONFIRM button Function Setting and cancel to the timer and other additional functions...

Page 3: ... if kept depressed it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 3 Fan speed selection 2 Select temp setting Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature 1 Unit start Pres...

Page 4: ...th function 1 TURBO Operation 2 QUIET Operation Note When you need rapid heating or cooling you can use this function You can use this function when silence is needed for rest or reading During TURBO operation in rapid COOL mode the room will show inhomogeneous temperature distribution Long period QUIET operation will cause effect of not too cool or not too warm Press QUIET button the remote contr...

Page 5: ...hours temp risesby 1 futher The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep O C 1O C Press button to enter additional options when cycle display to will flash And then press enter to sleep function O Note When TIMER function is set the sleeping function can t be set up After the sleeping function is set up i...

Page 6: ...erious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping then wipe off the detergent completely Indoor Body Once every two weeks 1 Open the lnlet Grille 2 Detach the standard air filter 3 Attach Air Purifying Filter 4 Attach the standard air filter Necessary installation 5 Close the Inlet Grille Close the Grille surely Slide the knob slightly upward t...

Page 7: ...t try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at the same time PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fire...

Page 8: ...lter dirty Are there any obstacles before inlet and outlet Is temperature set correctly Are there some doors or windows left open Is there any direct sunlight through the window during the Are there too much heat sources or too many people in the room regardless of FAN setting during cooling operation cooling operation Use curtain Normally it should be cleaned every 15 days be heard At first 2 3 m...

Page 9: ... T ﻓﻮﻟﺖ ٢٥٠ ﺃﻣﺒﻴﺮ ٢٥ T ﺍﻷﺳﻼﻙ ﺗﻮﺻﻴﻞ ﻓﻲ ﺑﻪ ﺍﻟﻤﻌﻤﻮﻝ ﺍﻟﻤﺤﻠﻲ ﺍﻟﻤﻌﻴﺎﺭ ﻣﻊ ﺍﻷﺳﻼﻙ ﺗﻮﺻﻴﻞ ﻃﺮﻳﻘﺔ ﺗﺘﻤﺎﺷﻰ ﺃﻥ ﻳﺠﺐ ٣ ﺳﻬﻼ ﺍﻟﻄﺎﻗﺔ ﻣﻘﺒﺲ ﺇﻟﻰ ﺍﻟﻮﺻﻮﻝ ﻳﻜﻮﻥ ﺃﻥ ﻳﺠﺐ ﺍﻟﺘﺮﻛﻴﺐ ﺑﻌﺪ ٤ ﺳﻠﻴﻢ ﺑﺸﻜﻞ ﺍﻟﻤﻨﺘﻬﻴﺔ ﺍﻟﺒﻄﺎﺭﻳﺔ ﻣﻦ ﺍﻟﺘﺨﻠﺺ ﻳﺠﺐ ٥ ﺍﻹﻋﺎﻗﺎﺕ ﺃﺻﺤﺎﺏ ﺍﻷﺷﺨﺎﺹ ﺃﻭ ﺍﻟﺴﻦ ﺻﻐﺎﺭ ﺍﻷﻃﻔﺎﻝ ﻗﺒﻞ ﻣﻦ ﻟﻼﺳﺘﺨﺪﺍﻡ ﻣﺼﻤﻢ ﻏﻴﺮ ﺍﻟﺠﻬﺎﺯ ﻫﺬﺍ ٦ ﺇﺷﺮﺍﻑ ﺩﻭﻥ ﺑﺎﻟﺠﻬﺎﺯ ﻋﺒﺜﻬﻢ ﻋﺪﻡ ﻟﻀﻤﺎﻥ ﺍﻷﻃﻔﺎﻝ ﻣﺮﺍﻗﺒﺔ ﻓﻴﺠﺐ ٧ ﺍﻟﻄﺎﻗﺔ ﺳﻠﻚ ﻣﻊ ﻳﺘﻨﺎﺳﺐ ﺍﻟﺬﻱ ﺍﻟﺼﺤﻴﺢ ﺍﻟﻜﻬﺮﺑﺎء ﻣﻘﺒﺲ ﺍﺳﺘﺨﺪﺍﻡ ﻳﺮﺟﻰ ٨ ﻣﺤﻠﻴﺔ ...

Page 10: ...ﻭﻉ ﺍﻟﻬﻭﺍء ﻭﻣﺧﺭﺝ ﻣﺩﺧﻝ ﻓﻲ ﺃﺷﻳﺎء ﺇﺩﺧﺎﻝ ﺗﺟﻧﺏ ﺍﻟﻁﺎﻗﺔ ﺳﻠﻙ ﺇﺗﻼﻑ ﻣﻥ ﺍﺣﺫﺭ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﺣﺯﻣﺔ ﺃﻭ ﺭﺑﻁﺔ ﻓﻲ ﻭﻫﻭ ﺍﻟﻛﻬﺭﺑﺎء ﺳﻠﻙ ﺗﺳﺗﺧﺩﻡ ﻻ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﺍﻷﺭﺿﻲ ﺍﻟﻛﺎﺑﻝ ّﻝ ﺻ ﻭ ﺇﻋﺎﺩﺓ ﺃﻭ ﺍﻟﺗﺻﻠﻳﺢ ﺗﺣﺎﻭﻝ ﻻ ﺑﻧﻔﺳﻙ ﺍﻟﺗﺭﻛﻳﺏ ﺍﻷﺷﺧﺎﺹ ﺇﻟﻰ ﻣﺑﺎﺷﺭﺓ ﻳﺗﺟﻪ ﺍﻟﻬﻭﺍء ﺗﺩﻓﻕ ﺗﺟﻌﻝ ﻻ ﺍﻟﺳﻥ ﻛﺑﺎﺭ ﺃﻭ ﺍﻟﺭﺿﻊ ﺧﺎﺻﺔ ﻁﺭﻳﻕ ﻋﻥ ﺍﻟﺗﺷﻐﻳﻝ ﺗﻭﻗﻑ ﺃﻭ ﺗﺑﺩﺃ ﻻ ﻭﻛﻬﺫﺍ ﺍﻟﻛﻬﺭﺑﺎء ﺳﻠﻙ ﻓﺻﻝ ﺗﻧﺑﻳﻪ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﻣﻣﻧﻭﻉ ﻣﺑﻠﻠﺔ ﻳﺩﻙ ﻛﺎﻧﺕ ﺇﺫﺍ ﺍﻟﻣﻔﺗﺎﺡ ﺑﺗﺷﻐﻳﻝ ﺗﻘﻡ ﻻ ﺇﺫ...

Page 11: ...ﻐﻴﻞ ﺃﻭﻗﻒ ﻃﻮﻳﻠﺔ ﻟﻔﺘﺮﺓ ﺍﻟﻄﺎﻗﺔ ﻣﺰﻭﺩ ﺳﻠﻚ ﻣﻔﺘﺎﺡ ﺍﻟﺘﻬﻮﻳﺔ ﻓﺘﺤﺎﺕ ﺍﺳﺘﺨﺪﻡ ﻓﻌﺎﻟﺔ ﺑﺼﻮﺭﺓ ﺍﻟﺸﻤﺲ ﺃﺷﻌﺔ ﺇﺣﺠﺐ ﻃﺮﻳﻖ ﻋﻦ ﺍﻟﺘﺸﻐﻴﻞ ﺃﺛﻨﺎء ﻏﻄﺎء ﺃﻭ ﺳﺘﺎﺭﺓ ﺍﻟﻬﻮﺍء ﺗﻄﻬﻴﺮ ﻓﻠﺘﺮ ﺍﺳﺘﺒﺪﺍﻝ ﺍﻟﺪﺧﻮﻝ ﺷﺒﻜﺔ ﺍﻓﺘﺢ ١ ﺻﻐﻴﺮﺓ ﺃﺩﺍﺓ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﻟﺪﺧﻮﻝ ﺷﺒﻜﺔ ﺃﺧﺮﺝ ﻓﻲ ﻣﻮﺟﻮﺩﺓ ﻭﻫﻲ ﺍﻟﺸﺒﻜﺔ ﺩﻋﺎﻣﺔ ﺗﺴﻤﻰ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺍﻷﻳﻤﻦ ﺍﻟﺠﺎﻧﺐ ﺍﻟﻘﻴﺎﺳﻲ ﺍﻟﻬﻮﺍء ﻓﻠﺘﺮ ﺑﻔﻚ ﻗﻢ ٢ ﺍﺳﺤﺒﻪ ﺛﻢ ﺍﻟﻔﻠﺘﺮ ﻟﻔﻚ ﻷﻋﻠﻰ ﻗﻠﻴﻼ ﺍﻟﻤﻘﺒﺾ ﺣﺮﻙ ﺍﻟﻬﻮﺍء ﺗﻄﻬﻴﺮ ﻓﻠﺘﺮ ﺐ ّ ﺭﻛ ٣ ﻓﻲ ﺍﻟﻬﻮﺍء ﺗﻄﻬﻴﺮ ﻓﻠﺘﺮ ﺃﺟﻬﺰﺓ ﺿﻊ...

Page 12: ...ﺍﻟﻬﻮﺍء ﺗﺪﻓﻖ ﻋﻤﻠﻴﺔ ﺍﻟﻤﺮﻳﺢ ﺍﻟﻨﻮﻡ ﺇﻟﻰ ﺍﻟﺸﺎﺷﺔ ﺗﺪﻭﻳﺮ ﻋﻨﺪ ﺍﻹﺿﺎﻓﻴﺔ ﺍﻟﺨﻴﺎﺭﺍﺕ ﺇﻟﻰ ﻟﻠﺪﺧﻮﻝ ﺍﻟﺰﺭ ﺍﺿﻐﻂ ﺍﻟﻨﻮﻡ ﻭﻇﻴﻔﺔ ﺇﻟﻰ ﻟﻠﺪﺧﻮﻝ ﻋﻠﻰ ﺍﺿﻐﻂ ﺫﻟﻚ ﺑﻌﺪ ﻳﻮﻣﺾ ﺳﻮﻑ ﺍﻟﺘﺸﻐﻴﻞ ﻭﺿﻊ ﺟﺎﻑ ﺑﺎﺭﺩ ﺍﻟﻮﺿﻊ ﻓﻲ ١ ﺑﻤﻘﺪﺍﺭ ﺃﻋﻠﻰ ﺍﻟﺤﺮﺍﺓ ﺩﺭﺟﺔ ﺳﺘﺼﺒﺢ ﺍﻟﻨﻮﻡ ﻭﺿﻊ ﺑﺪء ﻣﻦ ﺳﺎﻋﺔ ﺑﻌﺪ ﺗﺮﺗﻔﻊ ﺃﺧﺮﻯ ﺳﺎﻋﺔ ﻭﺑﻌﺪ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺇﻋﺪﺍﺩ ﻋﻦ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ١ ﻟﻤﺪﺓ ﺍﻟﻮﺣﺪﺓ ﺳﺘﻌﻤﻞ ﺃﺧﺮﻯ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ١ ﺑﻤﻘﺪﺍﺭ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺩﺭﺟﺔ ﺇﻋﺪﺍﺩ ﻣﻦ ﺃﻋﻠﻰ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺗﻜﻮﻥ ﺗﺘﻮﻗﻒ ﺛﻢ ﺃﺧﺮﻯ ﺳﺎﻋﺎﺕ ٦ ﻧﺎ...

Page 13: ...ﺍﻟﻤﺆﻗﺖ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻟﻤﺮﻏﻮﺏ ﺍﻟﺘﺸﻐﻴﻞ ﻭﺿﻊ ﺍﺧﺘﺮ ﺍﻟﻮﺣﺪﺓ ﺗﺸﻐﻴﻞ ﺑﻌﺪ ١ ﺍﻟﻀﻐﻂ ﻓﻴﻬﺎ ﻳﺘﻢ ﻣﺮﺓ ﻛﻞ ﻓﻲ ﺍﻟﻤﺆﻗﺖ ﻭﺿﻊ ﻟﺘﻐﻴﺮ ﺍﻟﻤﺆﻗﺖ ﺯﺭ ﺍﺿﻐﻂ ٢ ﻛﺎﻵﺗﻲ ﺍﻟﺸﺎﺷﺔ ﺗﺘﻐﻴﺮ ﺍﻟﺰﺭ ﻋﻠﻰ ﺑﻌﺪ ﻋﻦ ﺍﻟﺘﺤﻜﻢ ﺟﻬﺎﺯ ﺗﺸﻐﻴﻞ ﺃﻭ ﺍﻟﻤﺆﻗﺖ ﺇﻳﻘﺎﻑ ﺃﻭ ﺍﻟﻤﺆﻗﺖ ﺗﺸﻐﻴﻞ ﺍﻟﻤﻄﻠﻮﺏ ﺍﻟﻤﺆﻗﺖ ﻭﺿﻊ ﺍﺧﺘﺮ ﺛﻢ ﻳﻮﻣﺾ ﺳﻮﻑ ﺃﻭ ﺍﻟﻤﺆﻗﺖ ﺇﻳﻘﺎﻑ ﺍﻟﻮﻗﺖ ﻟﻀﺒﻂ ﺍﻟﺰﺭ ﺍﺿﻐﻂ ٣ ﺳﺎﻋﺔ ٠ ٥ ﺑﻤﻌﺪﻝ ﺳﺎﻋﺔ ١٢ ﺃﻭﻝ ﻓﻲ ﺍﻟﻀﺒﻂ ﻭﻗﺖ ﻳﺰﻳﺪ ﻣﺮﺓ ﻟﻜﻞ ﺍﻟﺰﺭ ﺍﺿﻐﻂ ﻣﺮﺓ ﻛﻞ ﻓﻲ ﺳﺎﻋﺔ ١ ﺑﻤﻌﺪﻝ ﻳﺰﻳﺪ ﺳﺎﻋﺔ ١٢ ﻭﺑﻌﺪ ﻣﺮﺓ ﻛﻞ ﺳﺎﻋﺔ ٠ ...

Page 14: ...ﻓﻲ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺯﺭ ﻋﻠﻰ ﺍﺿﻐﻂ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺇﻋﺪﺍﺩ ﺍﺧﺘﺮ ٢ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺇﻋﺪﺍﺩ ﻳﺰﻳﺪ ﺍﻟﺰﺭ ﻋﻠﻰ ﺍﻟﻀﻐﻂ ﻓﻴﻬﺎ ﻳﺘﻢ ﻣﺮﺓ ﻛﻞ ﻓﻲ ﺑﺴﺮﻋﺔ ﻳﺰﻳﺪ ﺳﻮﻑ ﺍﻟﻀﻐﻂ ﺍﺳﺘﻤﺮ ﻭﺇﺫﺍ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ١ ﺑﻤﻘﺪﺍﺭ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺇﻋﺪﺍﺩ ﻳﻘﻞ ﺍﻟﺰﺭ ﻋﻠﻰ ﺍﻟﻀﻐﻂ ﻓﻴﻬﺎ ﻳﺘﻢ ﻣﺮﺓ ﻛﻞ ﻓﻲ ﺑﺴﺮﻋﺔ ﻳﻘﻞ ﺳﻮﻑ ﺍﻟﻀﻐﻂ ﺍﺳﺘﻤﺮ ﻭﺇﺫﺍ ﻣﺌﻮﻳﺔ ﺩﺭﺟﺔ ١ ﺑﻤﻘﺪﺍﺭ ﺍﻟﻤﻄﻠﻮﺑﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺩﺭﺟﺔ ﺍﺧﺘﺮ ﺍﻟﻤﺮﻭﺣﺔ ﺳﺮﻋﺔ ﺍﺧﺘﻴﺎﺭ ٣ ﺍﻟﻤﺮﻭﺣﺔ ﺳﺮﻋﺔ ﺗﺘﻐﻴﺮ ﺿﻐﻄﺔ ﻛﻞ ﻣﻊ ﺍﻟﻤﺮﻭﺣﺔ ﺯﺭ ﻋﻠﻰ ﺍﺿﻐﻂ ﻳﻠﻲ ﻛﻤﺎ ﺑﻌﺪ ﻋﻦ ﺍﻟﺘﺤﻜﻢ ﺟﻬﺎﺯ ﻋﻠﻰ...

Page 15: ...ﺒﻄﺔ ﻭﺍﻟﻮﻇﺎﺋﻒ ﺍﻟﺸﺎﺷﺎﺕ ﻋﻠﻰ ﺗﺤﺘﻮﻱ ﻻ ﻓﻘﻂ ﺗﺒﺮﻳﺪ ﺑﻬﺎ ﺍﻟﺘﻲ ﺍﻟﻮﺣﺪﺓ ﺑﻬﺎ ﺍﻟﺨﺎﺻﺔ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ﻓﺘﺠﺎﻫﻞ ﺑﻬﺎ ﻳﻜﻦ ﻟﻢ ﻭﺇﺫﺍ ﻓﺎﺗﺒﻌﻬﺎ ﺻﺤﻴﺔ ﻭﻇﻴﻔﺔ ﺑﻬﺎ ﺍﺷﺘﺮﻳﺘﻬﺎ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺒﻄﺎﺭﻳﺔ ﺗﺮﻛﻴﺐ ﻣﻼﺣﻈﺔ ﺍﻟﻐﻄﺎء ﺗﺮﻛﻴﺐ ﺃﻋﺪ ﺛﻢ ﺍﻟﺒﻄﺎﺭﻳﺔ ﺐ ّ ﺭﻛ ٤ ﺍﻟﺒﻄﺎﺭﻳﺔ ﻏﻄﺎء ﺑﻔﻚ ﻗﻢ ١ ﻣﻮﺿﺢ ﻫﻮ ﻛﻤﺎ ﺍﻟﺒﻄﺎﺭﻳﺎﺕ ﺐ ّ ﺭﻛ ٢ ﺍﻟﻀﺒﻂ ﺇﻋﺎﺩﺓ ﻣﻔﺘﺎﺡ R 03 ﻧﻮﻉ ﻣﻦ ﺑﻄﺎﺭﻳﺘﺎﻥ ﺃﺳﻄﻮﺍﻧﻲ ﻣﻊ ﻳﺘﻤﺎﺷﻰ ﺍﻟﺘﺮﻛﻴﺐ ﺃﻥ ﻣﻦ ﺗﺄﻛﺪ ٣ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺬﻱ ﺍﻟﻤﻨﺘﺞ ﺣﺴﺐ ﺍﻟﺪﻟﻴﻞ ﻓﻲ ﺍﻟﻤﻌﺮﻭﺿﺔ ﺗﻠﻚ ﻋﻦ ...

Page 16: ...ﺕ 7 ﻭﺇﺻﻼﺣﻬﺎ ﺍﻷﺧﻄﺎء ﺍﺳﺘﻜﺸﺎﻑ ﻟﻠﺮﺟﻮﻉ ﻫﺬﺍ ﺍﻟﺘﺸﻐﻴﻞ ﺑﺪﻟﻴﻞ ﺍﺣﺘﻔﻆ ﺍﻟﻬﻮﺍء ﻣﻜﻴﻒ ﺍﺳﺘﺨﺪﺍﻡ ﻗﺒﻞ ﻫﺬﺍ ﺍﻟﺘﺸﻐﻴﻞ ﺩﻟﻴﻞ ﻗﺮﺍءﺓ ﻳﺮﺟﻰ ﻣﺴﺘﻘﺒﻼ ﺇﻟﻴﻪ ﺗﺎﻳﻼﻧﺪ ﻓﻲ ﺻﻨﻊ 0010571257 FATP24FNVWHE FATP24FNVWHC FATC28FNVWHE FATC28FNVWHC FATP28FNVWHE FATP28FNVWHC FATC18FNVWHE FATC18FNVWHC FATP18FNVWHE FATP18FNVWHC FATC24FNVWHE FATC24FNVWHC ...

Reviews: