Summary of Contents for FARE4044MW0

Page 1: ......

Page 2: ...t editions for HOME USE only This dryer is not recommended for commercial applications such as restaurants beauty salons etc Do not install a clothes dryer with flexible plastic or flexible foil venting material Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire The instructions in this...

Page 3: ...ting Free flowing clear of lint buildup 4 inch 102 mm rigid or semi rigid ducting of minimal length and turns NO foil or plastic venting material Approved vent hood exhausted to outdoors Leveling Dryer is level side to side and front to back Cabinet is setting solid on all corners Gas Supply Gas Dryer Manual shutoff valve present in supply All connections sealed with approved sealer and wrench tig...

Page 4: ...permit grounding OUTLET RECEPTACLE NEMA 10 30R or NEMA 14 30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GROUNDING CONNECTION See Grounding requirements in Electrical Installation section 3 WIRE POWER SUPPLYCORD KIT not supplied 3 wire receptacle NEMA type 10 30R The dryer MUST employ a 3 conductor power supply cord NEMA 10 30 type S...

Page 5: ...codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve installed in accordance with the B149 1 Natural Gas and Propane Installation Code B A 1 8 inch 0 32 cm N RT plugged tapping accessible for test gauge connection MUST be instal...

Page 6: ...D Failure to follow these instructions can create excessive drying times and fire hazards The following are specific requirements for proper and safe operation of your dryer FIRE HAZARD Do not install a clothes dryer with flexible plastic or metal foil venting materials Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer air...

Page 7: ...e hazard Do not screen the exhaust ends of the vent system or use any screws rivets or other fasteners that extend into the duct to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and ii creating a fire hazard as well as increasing drying ii times Use an approved vent hood to terminate the duct outdoors and seal all joints with metal ...

Page 8: ...ystem is acceptable certain extenuating circumstances could affect the performance of the dryer o Only rigid metal duct work should be used Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint Compression or crimping of the ...

Page 9: ...ling a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 6 Installer MUST anchor this 1 dryer or 2 dryer mounted on pedestal to the floor with approved Mobile Home Installation Kit P N 137067200 Installation in a Recess or Closet 1 A dryer installed in a bedroom bathroom recess or closet MU...

Page 10: ... it must be a minimum of 18 inches 45 7 cm above the floor Failure to do so can result in death exp os on fire or burns MINIMUM INSTALLATION CLEARANCES Inches cm SIDES REAR TOP FRONT Alcove 0 0 cm 0 0 cm 23 58 5 cm n a Closet 0 0 cm 0 0 cm 23 58 5 cm 1 2 5 cm Dryer must be vented straight back to achieve 0 0 cm rear installation 0 0 0 cm 0 cm 1 0 2 5 cm 0 cm _ _ _ _ _ f l Dryer Dimensions I_ 27 68...

Page 11: ... The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle Dryers operating on 208 volt power supply will have longer drying times than dryers operating on 240 volt Grounding requirements Electric dryer USA ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if...

Page 12: ... accordance with all local codes and ordinances If in doubt call a licensed electrician 3 DO NOT modify the plug provided with this appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician Grounding requirements Gas dryer USA and Canada I The dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged d...

Page 13: ...r the connection Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections Shutoff Valve Open position Manual GAS FLOW Shutoff Flare _ Flare Valve Union Union l sed _ _ Nipple Flexible Inlet Pipe on Open Connector Back of Dryer All connections must be wrench tightened 4 Check for gas system leaks with a manometer If a manometer is not avai...

Page 14: ...re conductor to the SILVER colored center terminal on the terminal block Tighten the screw securely 6 Attach the remaining two power cord outer conductors to the outer BRASS colored terminals on the terminal block Tighten both screws securely ELECTR ICAL SHOCK HAZARD Do not make a sharp bend or crimp wiring conductor at connections 7 Follow manufacturer s guidelines for firmly securing the strain ...

Page 15: ...rew Tighten the screw securely 7 Move the internal dryer harness ground WHITE wire to the terminal block and attach it along with the neutral WHITE power cord wire conductor to the center SILVER colored terminal on the terminal block Tighten the screw securely 8 Attach the RED and BLACK power cord conductors to the outer BRASS colored terminals on the terminal block Tighten both screws securely EL...

Page 16: ...r to comer 4 Press down on alternate corners and sides and feel for the slightest movement Adjust the appropriate leg s so the dryer sits solidly on the floor on ALL four legs Keep the leveling leg extension at a minimum for best performance of the dryer Be sure the power is off at a circuit breaker fuse box before PlUgging the power cord into an outlet 5 Plug the power cord into a grounded outlet...

Page 17: ...ss otherwise noted Figure below Place door on a towel front side down to prevent scratches to paint or window if equipped Remove all four remaining long hinge screws on edge of door Figure below Youmayneeda plasticknifeto helppullout the plugs Be careful not to scratch the paint ii o D STAMPED ON DOOR SIDE OF HINGE INTERIOR Begin removing the four short screws that attach the hinge to the front pa...

Page 18: ...e hole to the top hole in the front panel door opening Once the first short screw is started attach the second short screw to the lower hinge Once both screws are tightened install the remaining two short screws Figure below D STAMPED ON DOOR SIDE OF HINGE INTERIOR 6 Install four long screws into holes that had secured the hinges Figure above 7 Remove striker and discard Figure below 8 Remove squa...

Page 19: ...Other colors may be available Contact the source where you purchased your dryer Technical Sheet Wiring Diagram A wiring diagram and technical data sheet are located To remove the console faceplate follow the directions below 1 Disconnect dryer from electrical source 2 Remove the hole plugs on the back of the console housing 3 Insert a small straight blade screw drive to gently pry downward on each...

Page 20: ......

Page 21: ...INDICE Instrucdones importantes de seguridad 22 23 Inversi6n de la puerta 37 38 Requisitos de instalaci6n 24 30 Accesorios 39 Instrucdones de instalaci6n 3 36 ...

Page 22: ...ecomienda esta secadora para uso comercial como pot ejemplo en restaurantes salones de belleza etc No utilice materiales de ventilad6n de pl_stico ni de papel de aluminio flexibles para instalar la secadora de ropa Por Io general dichos materiales se desarman se deterioran con facilidad y acumulan pelusa Estas condiciones obstruyen el flujo de aire de la secadora y aumentan el riesgo de incendio L...

Page 23: ...iales de ventilaci6n de aluminio o de pl_stico 3 El sistema de evacuaci6n debe ventilar al exterior y contar con una capucha de ventilaci6n aprobada Nivelaci6n La secadora est_ nivelada de lado a lado y de adelante hacia atr_s El secadora descansa firmemente sobre sus cuatro esquinas Suministro de gas secadora a gas V_lvula de cierre manual instalada en la tuber a de suministro Todas las conexione...

Page 24: ...s de conexi6n a tierra en la secci6n Instalaci6n el4ctrica CABLE DE ALIMENTACION ELF_CTRICA TRIFILAR no incluido Recept_culo trifilar tipo NEMA 10 30R La secadora DEBE emplear un cable de alimentaci6n el4ctrica de 3 conductores tipo NEMA 10 30 SRDT calificado para CA minima de 240 voltios 30 amp con 3 conectores de terminal horquilla con extremos doblados hacia arriba o de bucle cerrado y califica...

Page 25: ...e de acuerdo con los c6digos locales o en ausencia de ellos con el C6digo de Gas Nacional National Fuel Gas Code ANSI Z223 1 Oltima edici6n 2 La I nea de suministro de gas debe ser un tubo de 1 27 cm 1 2 pulgada 3 Si los c6digos Io permiten se puede utilizar un tubo de metal flexible para conectar la secadora a la I nea de suministro de gas La tuber a DEBE ser de acero inoxidable o de lat6n plasti...

Page 26: ...IGRO DE INCENDIO Ei no seguir estas instrucciones puede producir tiempos exc vo i ncend o Los siguientes son requisitos necesarios para el fun cionarniento seguro y correcto de su secadora PELIGRO DE INCENDIO No utilice materiales de ventilaci6n de pl_stico ni de papel de aluminio flexibles para instalar la secadora de ropa Por Io general dichos materiales se desarman se deterioran con facilidad y...

Page 27: ...os remaches ni otros sujetadores que se extiendan hacia la parle interna del conducto para ensamblarlo Es posible que la pelusa quede atrapada en el filtro los tornillos o los ii remaches Io que puede obstruir la red de conductos ii y constituir un peligro de incendio as como tambi6n aumentar los tiempos de secado En la salida del conducto al exterior utilice una capucha de ventilad6n aprobada y s...

Page 28: ...drfan afectar el funcionamiento de la secadora o 61o se debe utilizar una red de conductos de metal r gido Si la ventilaci6n se efectOa en forma vertical a trav_s del techo es posible que el sistema de escape se vea expuesto a r_fagas descendentes que restringir_n la ventilad6n Si el sistema de escape se extiende a trav_s de un area que no est_ aislada puede producirse condensad6n y una acumulad6n...

Page 29: ...en una casa rodante se debe dejar espacio en el exterior para la salida de aire Este espacio debe ser por Io menos el doble del area de la salida de escape de la secadora 6 El t6cnico de instalaci6n DEBE anclar esta secadora 1 o secadora sobre pedestal 2 al piso usando un kit de instalaci6n para casas rodantes pieza n0mero 137067200 Instalacibn en un Nicho o Armario Una secadora instalada en un do...

Page 30: ...rio podrfa producirse una explosi6n un incendio quemaduras o inc uso a muerte Dimensiones de la Secadora ESPACIOS MINIMOS PAPALA INSTALACION cm pulgadas PARTE PARTE PARTE LATERALES TRASERA SUPERIOR DELANTERA Alc6ve 0 crn 0 0 crn 0 58 5 crn 23 n d Placard 0 crn 0 0 cm 0 58 5 cm 23 2 5 crn 1 La ventilaci6n derecho hacia arras permite la instalaci6n de la secadora a 0 0 cm de la pared 0 0 0 cm 0 cm i...

Page 31: ...ulo y el cableado correcto consiste en un cable de alimentaci6n con alambres de cobre con unrecePt _culod ca sde Las secadoras que funcionan con 208 voltios de corriente el_ctrica tendr_n tiempos de secado m_s prolongados que las que funcionan con 240 voltios de corriente el_ctrica RequJsitos de cone J6n a tJerra secadora ei_ctrica Estados Unidos PELIGRO DE DESCARGA EI i_CTRICA Una conexi6n incorr...

Page 32: ...r duda comun quese con un electricista autorizado NO realice modificaciones al enchufe que se proporciona con este artefacto Si no calza en el tomacorrientes pfdale a un electricista calificado que instale un tomacorrientes adecuado Requisitos de conexi6n a tierra secadora a gas Estados Unidos y Canada La secadora est_ equipada con un enchufe de tres patas conexi6n a tierra para evitar el peligro ...

Page 33: ...V_lvula de cierre Conector Conector manual doble doble Conector Tubo de admisi6n flexible en la parte posterior de la secadora Todas las conexiones deben estar ajustadas con Ilave Abra la v_lvula de cierre de la I nea de suministro de gas para que el gas fluya a trav_s de la tuber a Espere unos minutos a que el gas fluya a trav_s de la I nea de suministro de gas 4 Utilice un man6metro para verific...

Page 34: ...ecte los dos conductores externos restantes del cable de alimentaci6n a los terminales externos de color LATON del bloque terminal Ajuste los dos tornillos con firmeza PELIGRO DE DESCARGA ELI_CTRTCA No forme un c_nguloagudo con el cableado conductor ni los doble en el punto de conexiOn 7 Siga las pautas del fabricante para sujetar firmemente el dispositivo de liberation de tension y e cable de ali...

Page 35: ...onexi6n a tierra que integra el enchufe preformado de la secadora al bloque terminal y con_ctelo junto con e conductor neutro BLANCO de cable de alimentaci6n al terminal PLATEADOdel centro del bloque terminal Ajuste el tornillo con firmeza 8 Conecte los conductores RO30 y NEGRO del cable de a imentaci6n a los terminales externos de color LATON del bloque terminal Ajuste los dos tornillos con firme...

Page 36: ...a asegurarse de que no haya vibraci6n alguna Ajuste las paras correspondientes de modo que la lavadora descanse firmemente en el piso sobre las CUATRO paras Mantenga la extensi6n de las patas niveladoras al mfnimo para un mejor rendimiento de la secadora Revise la caja del interruptor autom_tico fusibles para asegurarse de que la electricidad est_ desconectada antes de conectar el cable de aliment...

Page 37: ...stico para poder sacar los receptores Tenga cuidado de no rayar la pintura Acueste la puerLa sobre una toalla con la superficie delantera hacia abajo para evitar rayar la pintura o la ventanilla si se incluye Retire los cuatro tornillos largos restantes de la bisagra del borde de la puerla Como se muestra en la figura m_s abajo TAPONES 4 _ _ _ TORNtLLOS DE LA BISAGRA DEL PANEL I I DELANTERO x 4 e ...

Page 38: ...a de la puerta Una vez que el primer tornillo corto quede insertado inserte e segundo tornillo corto en la bisagra inferior Una vez que ambos tornillos est6n instalados apriete los otros dos tornillos cortos Como se muestra en la figura m_s abajo D ESTAMPADA EN EL LADO DE LA PUERTA DEL INTERIOR DE LA BISAGRA 6 Instale cuatro tornillos largos en los agujeros que sostenfan las bisagras Como se muest...

Page 39: ...s a la propiedad o da_os a la secadora Dentro e a consoa a seca ora encont r una hera de informaci6n t_cnica y un diagrama de cableado Para retirar la placa delantera de la consola siga estas instrucciones 1 Desconecte la secadora del suministro de electricidad 2 Retire los tapones de los agujeros en la parte trasera del alojamiento de la consola 3 Introduzca un destornillador piano recto de tama_...

Reviews: