background image

GAS COOKTOP INSTALLATION INSTRUCTIONS

9

4

.   Adjust the “lOW” setting for regular 

surface burner valves (Figure 10) 

a. Push in and turn control to lITE until burner 

ignites.

b. 

Quickly 

turn knob to lOWEST POSITION.

c.  If burner goes out, reset control to OFF.

d. Remove the surface burner control knob.

e. Insert a thin-bladed screwdriver into the 

hollow valve stem and engage the slotted 

screw inside. Flame size can be increased 

or decreased with the turn of the screw. Turn 

counterclockwise to increase flame size. Turn 

clockwise to decrease flame size. Adjust flame 

until you can quickly turn knob from lITE to 

LOWEST POSITION without extinguishing the 

flame. Flame should be as small as possible 

without going out.

5. Adjust the "lOW" setting of the dual burner 

surface valve (Figure 10) (some models):

Note: On the dual valve the low setting of each 

portion should be adjusted individually. 

a. Push in and turn knob to lITE then continue 

to  turn until only the inner portion of the dual 

burner stays on.

b. 

Quickly 

turn knob to lOWEST POSITION.

c.  If burner goes out, reset control to OFF.

d. Remove the surface burner control knob.

e. The inner portion of the dual burner flame 

size can be increased or decreased with the 

turn of the screw 

B

. Use screw 

A

 to adjust the 

low flame size of the outer portion of the dual 

burner. Turn the screw counterclockwise to 

increase flame size. Turn the screw clockwise 

to decrease flame size. Adjust flame until you 

can quickly turn knob from HIGH to lOWEST 

POSITION without extinguishing the flame. 

Flame should be as small as possible without 

going out.

Note:

 Air mixture adjustment is not required on 

surface burners.

When All hookups are Complete

Make sure all controls are left in the OFF position.

Make sure the flow of combustion and ventilation 

air to the cooktop is unobstructed.

model and Serial Number location

The serial plate is located on the underside of the 

cooktop.
When ordering parts for or making inquires about 

your range, always be sure to include the model 

and serial numbers and a lot number or letter from 

the serial plate of your cooktop.
Your serial plate also tells you the rating of the 

burners,  the type of fuel and the pressure the 

cooktop was adjusted for when it left the factory.

Before You Call for Service

Read the Before You Call for Service Checklist 

and operating instructions in your 

Use and Care 

Guide

. It may save you time and expense. The 

list includes common occurrences that are not the 

result of defective workmanship or materials in 

this appliance. 
Refer to the warranty in your  

Use and Care 

Guide

 for our service phone number and address. 

Please call or write if you have inquiries about 

your product and/or need to order parts.

Figure 10

Regular

Burner 

Valve

Dual

Burner 

Valve

A

B

Hollow 

Valve 

Stem

Clockwise

Counterclockwise

Note:

 Air mixture adjustment is not required on 

surface burners.

Summary of Contents for 318205454 (1302)

Page 1: ...cm space underneath the cooktop for connection to gas supply line NOTE Wiring diagrams for this cooktop are enclosed in this booklet Printed in Canada Appliances Installed in the state of Massachusetts This Appliance can only be installed in the state of Massachusetts by a Massachusetts licensed plumber or gas fitter This appliance must be installed with a three 3 foot 36 in long flexible gas conn...

Page 2: ...read it carefully Air curtain or other overhead hoods which operate by blowing a downward air flow on to a range shall not be used in conjunction with gas ranges other than when the hood and range have been designed tested and listen by an independent test laboratory for use in combination with each other Be sure your cooktop is installed and grounded properly by a qualified installer or service t...

Page 3: ... Cutout and Nearest Combustible Surface Above Countertop Clearance 30 76 2 cm Min Clearance Between the Top of the Cooking Platform and Unprotected Wood or Metal Cabinet 13 33 cm Max Depth For Cabinet Installed Above Cooktop MODEL A B Minimum Clearance from Left Side C Minimum Clearance from Right Side 30 Cooktop 30 76 2 cm 9 22 9 cm 9 22 9 cm 2 5 7 cm Min From Counter Edge to Front Edge of Cutout...

Page 4: ...mounting hardware must be used to secure the built in oven to the cabinets Refer to the built in oven installation instructions Side filler panels are necessary to isolate the unit from adjoining cabinets Panel height should allow for installation of approved cooktop models See Typical Gas Cooktop Installation Over an Electric Built in Oven Installed Under the Counter on next page 36 91 4 cm Min J...

Page 5: ...alled Under the Counter FRONT VIEW SIDE VIEW Figure 4 Wall Oven Cabinet GAS COOKTOP GAS COOKTOP WALL OVEN Pressure Regulator Flare Union Flare Union Flexible Connector Cabinet sides or filler panel Manifold Pipe Manual Shutoff Valve To be accessible for shut off valve operation 18 45 7 cm Max Approx 6 16 5 cm ...

Page 6: ...converting to LP gas is supplied with your cooktop The kit is marked FOR LP PROPANE GAS CONVERSION The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements Failure to follow instructions could result in serious injury or property damage The qualified agency performing this work assumes responsibility for the con...

Page 7: ...s individual manual shutoff valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa or 14 water column Isolate the cooktop from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa or 1...

Page 8: ... protected by a 15 amp circuit breaker or time delay fuse Do not use an extension cord with this cooktop Grounding Instructions IMPORTANT Please read carefully For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall receptacle see Figure 9 to minimize the possibility o...

Page 9: ...rclockwise to increase flame size Turn the screw clockwise to decrease flame size Adjust flame until you can quickly turn knob from HIGH to LOWEST POSITION without extinguishing the flame Flame should be as small as possible without going out Note Air mixture adjustment is not required on surface burners When All Hookups are Complete Make sure all controls are left in the OFF position Make sure th...

Page 10: ...WIRING DIAGRAM ...

Page 11: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 11 NOTES ...

Page 12: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 12 NOTES ...

Reviews: