GAS COOKTOP INSTALLATION INSTRUCTIONS

4

CUTOUT DIMENSIONS (INCHES (CM))

OVEN 

SIZE

E. hEIghT

F. WIDTh

g. DEpTh

min.

max.

min.

max.

min.

30" (76.2)  27 ¼" (69,2 cm) 28¼" (71.8) 28½" (72.4) 29" (73.7)

23½" (59.7)

27" (68.6) 27 ¼" (69,2 cm) 28¼" (71.8) 24

7

/

8

" (63.2) 25¼" (64.1)

23½" (59.7)

*  If no cooktop is 

installed directly 

over the oven 

unit, 5” (12.7cm) 

maximum is 

allowed.

Typical Under Counter Installation of an Electric Built-in Oven 

with a Cooktop Mounted Above

Cut an opening in wood base 

minimum 4” (10.2 cm) x 4” (10.2 cm) 

to route armored cable to junction box.

4 1/2” (11.4 cm) 

Max.*

208/240 Volt 

grounded junction 

box for built-in 

oven.

 

All mounting 

hardware must be used to 

secure the built-in oven to 

the cabinets. Refer to the 

built-in oven installation 

instructions.

Side filler panels are necessary 

to isolate the unit from adjoining 

cabinets.  Panel height should 

allow for installation of approved 

cooktop models. See “Typical 

Gas Cooktop Installation Over 

an Electric Built-in Oven Installed 

Under the Counter” on next page.

36”

(91.4 cm) Min.

Junction box 

must be located 

approx. 3" to the 

left of the built-in 

oven cutout.

This cooktop may be 

installed over certain 

built-in electric oven 

models.

Figure 3

Use 3/4” (1.9 cm) 

plywood, installed on 

two runners, flush 

with toe plate. Base 

must be capable 

of supporting 150 

pounds (68 kg) for 

27" models and 200 

pounds (90 kg) for 

30" models.

Unit will 

overlap 

cutout 

(minimum) 

edges by 1" 

(2.5cm)

Summary of Contents for 318205454 (1302)

Page 1: ...cm space underneath the cooktop for connection to gas supply line NOTE Wiring diagrams for this cooktop are enclosed in this booklet Printed in Canada Appliances Installed in the state of Massachusetts This Appliance can only be installed in the state of Massachusetts by a Massachusetts licensed plumber or gas fitter This appliance must be installed with a three 3 foot 36 in long flexible gas conn...

Page 2: ...read it carefully Air curtain or other overhead hoods which operate by blowing a downward air flow on to a range shall not be used in conjunction with gas ranges other than when the hood and range have been designed tested and listen by an independent test laboratory for use in combination with each other Be sure your cooktop is installed and grounded properly by a qualified installer or service t...

Page 3: ... Cutout and Nearest Combustible Surface Above Countertop Clearance 30 76 2 cm Min Clearance Between the Top of the Cooking Platform and Unprotected Wood or Metal Cabinet 13 33 cm Max Depth For Cabinet Installed Above Cooktop MODEL A B Minimum Clearance from Left Side C Minimum Clearance from Right Side 30 Cooktop 30 76 2 cm 9 22 9 cm 9 22 9 cm 2 5 7 cm Min From Counter Edge to Front Edge of Cutout...

Page 4: ...mounting hardware must be used to secure the built in oven to the cabinets Refer to the built in oven installation instructions Side filler panels are necessary to isolate the unit from adjoining cabinets Panel height should allow for installation of approved cooktop models See Typical Gas Cooktop Installation Over an Electric Built in Oven Installed Under the Counter on next page 36 91 4 cm Min J...

Page 5: ...alled Under the Counter FRONT VIEW SIDE VIEW Figure 4 Wall Oven Cabinet GAS COOKTOP GAS COOKTOP WALL OVEN Pressure Regulator Flare Union Flare Union Flexible Connector Cabinet sides or filler panel Manifold Pipe Manual Shutoff Valve To be accessible for shut off valve operation 18 45 7 cm Max Approx 6 16 5 cm ...

Page 6: ...converting to LP gas is supplied with your cooktop The kit is marked FOR LP PROPANE GAS CONVERSION The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements Failure to follow instructions could result in serious injury or property damage The qualified agency performing this work assumes responsibility for the con...

Page 7: ...s individual manual shutoff valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa or 14 water column Isolate the cooktop from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa or 1...

Page 8: ... protected by a 15 amp circuit breaker or time delay fuse Do not use an extension cord with this cooktop Grounding Instructions IMPORTANT Please read carefully For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall receptacle see Figure 9 to minimize the possibility o...

Page 9: ...rclockwise to increase flame size Turn the screw clockwise to decrease flame size Adjust flame until you can quickly turn knob from HIGH to LOWEST POSITION without extinguishing the flame Flame should be as small as possible without going out Note Air mixture adjustment is not required on surface burners When All Hookups are Complete Make sure all controls are left in the OFF position Make sure th...

Page 10: ...WIRING DIAGRAM ...

Page 11: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 11 NOTES ...

Page 12: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 12 NOTES ...

Reviews: