10

Fresh Air Vent Control (On some models)

The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (see Fig. 1)
2. Draw fresh air into the room - Vent Open (see Fig. 2)
3. Exchange air from the room and draws fresh air into the room - Vent and Exhaust

Open (see Fig. 3)

Figure 1 (VENT CLOSED)

Figure 2 (VENT OPEN)

Figure 3 (VENT & EXHAUST OPEN)

ADDITIONAL THINGS YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.

• The “Cool “ circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the

compressor and possible circuit breaker tripping. The fan will continue to run during this time.

• The control will maintain the set temperature within 2 degrees Fahrenheit, between 60F and 90F degrees.

• The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other and back,

press and hold the “TEMP/TIMER” Up ( 

 ) and Down ( 

 ) buttons together for 3 seconds.

Air Conditioner Features

(continued)

(8-WAY)

AUGER WHEELS

Air Directional Louvers

Air directional louvers control air flow direction. Your air conditioner has the louver type
described below.

Auger Type

The louvers will allow you to direct the air flow Up or Down and Left or Right throughout
the room as needed. Rotate the Auger Wheels until the desired Left/Right direction is
obtained. Pivot horizontal louvers until the desired Up/Down direction is obtained.

SZ000400(En)-Yaokong

12/10/2004, 5:36 PM

10

Summary of Contents for 220202D019

Page 1: ... MULTI STEP SPEED ELECTRONIC CONTROL THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS P N 220202d019 SZ000400 En Yaokong 12 10 2004 5 36 PM 1 ...

Page 2: ...lfunction or defects in workmanship or material or for appliances not in ordinary household use The consumer shall pay for such service calls 3 Damages caused by services performed by persons other than authorized Frigidaire servicers use of parts other than Frigidaire Genuine Renewal Parts obtained from persons other than such servicers or external causes such as abuse misuse inadequate power sup...

Page 3: ...atter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser during normal ope...

Page 4: ...ze shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper rece...

Page 5: ...mbol for the functions you desire The unit can be controlled by the unit control alone or with the remote The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following 1 Plug in the Air Conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button You will notice a click as the RESET button po...

Page 6: ...utton is pressed the motor speed will slow down at multiple intervals 90 distinct settings to a minimum setting of 10 To speed the motor up press the FASTER button The speed will increase at multiple intervals to a maximum setting of 99 After 5 seconds the control will automatically change back to displaying the set temperature Note Tap or hold either up or down button until the desired temperatur...

Page 7: ...n cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can choose any fan speed you prefer During this function the display will show the actual room temperature not the set temperature as in the cooling mode TO USE THE ENERGY SAVER FEATURE D...

Page 8: ...On position Note For Delay Start the unit must be in the Off position To adjust timer setting tap or hold the UP arrow or the DOWN arrow V to change delay timer at 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start mode automatically selects cooling with maximum Fan Speed The temperature m...

Page 9: ...r to clean the Air Filter See Care and Cleaning for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off TO TURN UNIT OFF DO THIS PRESS ON OFF BUTTON SZ000400 En Yaokong 12 10 2004 5 36 PM 9 ...

Page 10: ...circuit breaker tripping The fan will continue to run during this time The control will maintain the set temperature within 2 degrees Fahrenheit between 60F and 90F degrees The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other and back press and hold the TEMP TIMER Up and Down buttons together for 3 seconds Air Conditioner Featur...

Page 11: ...efore replacing Or instead of washing you may vacuum the filter clean Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet fr...

Page 12: ...ode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower setting Air directio...