background image

10

Air Conditioner Features

(continued)

4-Way Air Directional Louvers

The 4-Way air directional louvers allow you to direct air flow up or down, left or
right throughout the room as needed. To adjust the air directional louvers side-
to- side, use the center handle as you move it side-to-side.

(4-WAY)

Care and Cleaning

Clean your air conditioner occasionally to keep it looking new.

Be sure to

unplug the unit before cleaning to prevent shock or fire hazards.

Air Filter Cleaning

Cabinet Cleaning

Winter Storage

The air filter should be checked at least once a month to see if cleaning is
necessary. Trapped particles in the filter can build up and cause an
accumulation of frost on the cooling coils.

Grasp the filter by the center and pull up and out.
Wash the filter using liquid dishwashing detergent and warm water. Rinse

filter thoroughly. Gently shake excess water from the filter. Be sure filter is
thoroughly dry before replacing.

Or, instead of washing you may vacuum the filter clean.

Be sure to unplug the air conditioner to prevent shock or fire hazard. The

cabinet and front may be dusted with an oil-free cloth or washed with a cloth
dampened in a solution of warm water and mild liquid dishwashing
detergent. Rinse thoroughly and wipe dry.

Never use harsh cleaners, wax or polish on the cabinet front.
Be sure to wring excess water from the cloth before wiping around the

controls. Excess water in or around the controls may cause damage to the
air conditioner.

Plug in air conditioner.

?

?

?

?

?

?

?

If you plan to store the air conditioner for the winter, cover it with plastic or
return it to the original carton.

NOTE: To prevent rust or electrical connections from being damaged,
store air conditioner in an upright position and a dry place.

Energy Saving Ideas

?

Do not block air flow inside with blinds, curtains or furniture; or

outside with shrubs, enclosures, or other buildings.

?

?

?

?

?
?

?

?

The capacity of the room air conditioner must fit the room size for efficient

and satisfactory operation.

Install the room air conditioner on the shady side of your home. A window

that faces north is best because it is shaded most of the day.

Close the fireplace damper, floor and wall registers so cool air does not

escape up the chimney and into the duct work.

Keep blinds and drapes in other windows closed during the sunniest part of

the day.

Clean the air filter as recommended in the section “Care and Cleaning.”
Proper insulation and weather stripping in your home will help keep warm

air out and cool air in.

External house shading with trees, plants or awnings will help reduce the

air conditioner's work load.

Operate heat producing appliances such as ranges, washers, dryers and

dishwashers during the coolest part of the day.

Summary of Contents for 000 BTU Slider

Page 1: ...s 10 Care and Cleaning 10 Energy Saving Ideas 11 Avoid Service Checklist 3 Packaging NOTE This USE CARE MANUAL provides specific operating instructions for your model Use the room air conditioner only as instructed in this USE CARE MANUAL instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operating an...

Page 2: ...rformed it is in your best interest to obtain and keep all receipts This written warranty gives you specific legal rights You may also have other rights that vary from state to state Service under this warranty must be obtained by following these steps in order 1 Contact Frigidaire Consumer Services or an authorized Frigidaire servicer 2 If there is a question as to where to obtain service contact...

Page 3: ... Chatter Today s high efficient compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporation during normal operation Pinging or Swishing Droplets of water hitting condenser during normal ...

Page 4: ...cal requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse o...

Page 5: ... TEMP SENSING INDICATOR SOME MODELS TURNS UNIT ON OR OFF ADJUSTS TEMPERATURE OR TIME SETS MODE ACTIVATES REMOTE THERMOSTAT some models REMOTE CONTROL w DISPLAY REMOTE SENSING BUTTON SETS FAN SPEED ACTIVATES TIMER HEAT MODE REMOTE CONTROL FOR HEAT MODELS Batter Size AAA WARRING Do not Mix Old And New Batteries Do Not Mix Alkaline Standare Carbon Zinc Or Rechargeable Nichel Cadmium Batteries 5 LIGHT...

Page 6: ... SELECT AUTO FAN YOU WILL SEE Note Tap or hold either up or down v button until the desired temperature is seen on display This temperature will be automatically maintained anywhere between 60F 16 C and 90F 32 C for cooling mode The Temperature will be automatically maintained anywhere between 55F 13 C and 80F 27 C for heating mode If you want the display to read the actual room temperature FAN SE...

Page 7: ...DO THIS PRESS TEMP TIMER BUTTON Note 1 For Delay Stop the unit must be in the ON position Note 2 For Delay Start the unit must be in the OFF position To adjust timer setting tap or hold the UP arrow or DOWN arrow v to change the delay time by 5 hour increments up to 10 hours then by 1 hour increments up to 24 hours The control will count down the timer remaining until start 8 7 5 7 etc The Delay S...

Page 8: ...same time pattern This ends the Sleep MODE and the unit will continue to operate as originally programmed The Sleep MODE program can be cancelled at any time during operation by pressing Sleep MODE button CHECK FILTER FEATURE Note This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation and cooling The LED light will illuminate after 250 hours of operat...

Page 9: ... and Down Temperature Selection Pads at the same time for 3 seconds The Cool circuit has an automatic3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time FAULT CODES If the display reads AS a sensor has failed Contact your Authorized Frigidaire Service Cen...

Page 10: ...er use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner If you plan to store the air conditioner for the winter cover it with plastic or return it to the original carton NOTE To prevent rust or electrical connections ...

Page 11: ...by drapes blinds furniture etc restricts air distribution Clear blockagein front of unit Doors windows registers etc open cold air escapes Close doors windows registers etc Unit recently turned on in hot room Allow additional time to remove stored heat from walls ceiling floor and furniture Dirty air filter air restricted Clean air filter Outside temperature extremely hot Set FAN speed to a faster...

Reviews: