External Drain (for new
construction or unit replacement)
When.using.an.external.drain.system,.the.condensate.is.removed.through.
either.of.two.drain.holes.on.the.back.of.the.wall.sleeve...Select.the.drain.
hole.which.best.meets.your.drainage.situation.and.install.the.drain.kit..
Seal.off.the.other.with.a.cover.plate.
Drain Tube Installation (See Figure 12)
1.
Peel.the.backing.tape.off.the.gaskets.and.apply.the.sticky.side.
to.one.cover.plate.and.one.mounting.plate.as.shown.in.Details.
A.and.B.
2.
Place.the.drain.tube.through.the.gasket.and.the.mounting.plate.
with.the.flange.toward.the.wall.sleeve.
3.
Attach.the.drain.tube.assembly.to.one.of.the.two.drain.holes.at.the.
rear.of.the.wall.sleeve...The.large.flange.on.the.mounting.plate.is.
positioned.at.the.bottom.of.the.sleeve.facing.toward.the.sleeve,.
Detail.B...When.the.drain.tube.is.positioned.at.the.desired.angle,.
tighten.the.screws..
Cover Plate Installation
4.
Mount.the.foam.gasket.to.the.cover.plate...Using.two.#10.x.½".sheet.
metal.screws.(provided),.attach.the.cover.plate.to.the.remaining.
drain.hole...Make.certain.the.large.flange.on.the.plate.is.positioned.
at.the.bottom.of.the.sleeve.
5.
Discard.the.additional.cover.plate,.gasket,.machine.screws,.and.
locknuts.
NOTE:.
The.large.flange.on.the.mounting.plate.is.positioned.at.the.bottom.of.the.sleeve.facing.toward.the.sleeve...The.drain.tube.must.be.rotated.to.a.
horizontal.position.to.allow.for.the.wall.sleeve.to.be.installed.into.the.wall...Once.the.wall.sleeve.is.installed,.return.the.drain.tube.to.a.downward.
angle.
Figure 12
Drain Kit Installation
NOTICE
If the wall sleeve has not been installed, the drain tube
must be rotated to a horizontal position until after the
sleeve is installed. Tighten the mounting plate screws
when the tube is in the proper position. Make certain that
the four overflow slots at the rear of the wall sleeve are not
blocked (See Figure 12).
When sealing the sleeve on the outside of the building, be
careful NOT to let the sealant block the two condensate
drain holes or the four overflow slots at the bottom flange
of the sleeve.
Potential property damage can occur if instructions are
not followed.
Summary of Contents for ZONEAIRE SELECT PZE07K3SA
Page 47: ...47 COMPONENT TESTING Electrical ...
Page 48: ...48 COMPONENT TESTING Electrical ...
Page 61: ...61 TROUBLESHOOTING MalfunctionAnalysis ...
Page 62: ...62 TROUBLESHOOTING Malfunction Analysis ...
Page 63: ...63 TROUBLESHOOTING Malfunction Analysis ...
Page 64: ...64 TROUBLESHOOTING Malfunction Analysis ...
Page 66: ...66 TROUBLESHOOTING HeatPump Figure 702 ...
Page 67: ...67 WIRING DIAGRAMS RemoteWallThermostatWiringDiagram CoolWithElectricHeat Figure 801 ...
Page 68: ...68 WIRING DIAGRAMS Remote Wall Thermostat Wiring Diagram HeatPumpWithElectricHeat Figure 802 ...
Page 69: ...69 Figure 803 WIRING DIAGRAMS ...
Page 71: ...71 PARTS CATALOG PZE Figure 901 ...