8
Wall Controller Installation
Pairing the Wall Controller and the Receiver
Wall Controller and Receiver must be paired in order to operate together. Once
paired, the Wall Controller cannot be used with another wireless Receiver without
repeating the pairing procedure. Friedrich Wall Controllers are pre-linked with the
card in the box.
In case of Network Installation with Remote Management, the Wall Controller and
the Receiver must be paired with a Network Programmer specific to the property
before the installation.
Wall Controller and Receiver must not be powered during the pairing procedure -
remove batteries from the Wall Controller and unplug the Receiver from the
VRP unit during the pairing procedure.
• Plug one programmer connector into the Wall Controller;
• Plug the other programmer connector into the Receiver;
• Push the black button on the programmer. The red light on the programmer
should turn on and remain steadily lit;
If the red light on the programmer is blinking or is not steadily lit, unplug the
programmer from the Wall Controller and the Receiver and repeat the steps
above.
• Unplug the programmer from the Wall Controller and the Receiver;
VPXEMWRT2-Thermostat Manual_pkg.indd 8
2017-12-15 3:37 PM