1
Figure 1 — B-Series VERT-I-PAK
NOTE: Read the entire instruction manual before starting the installation.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance, or use
can cause explosion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified installer,
service agency, or your distributor or dealer for information and assistance.
The qualified installer or agency must use factory-authorized parts or
accessories when modifying this product. Refer to the individual instructions
packaged with the parts or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves. Read these
instructions thoroughly and follow all warnings or cautions attached to the
unit. Consult local building codes, the National Electric Code (NEC), and
the Installation Standards, Warm Air Heating and Air Conditioning Systems
ANSI/NFPA 90B for special installation requirements.
Recognize safety information. This is the safety-alert symbol.
When
you see this symbol on the unit or in instructions and manuals, be alert to
the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION. These
words are used with the safety-alert symbol. DANGER identifies the most
serious hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices which would result in minor
personal injury or product and property damage. NOTE is used to convey
special or supplemental information or to repeat and emphasize information
previously provided.
INSTALLATION
INSTRUCTIONS
FRIEDRICH AIR CONDITIONING CO.
Date:
July 2000
Part No: 84016326 (IM010-01)
DANGER: Before installing or servicing system, always turn off main
power to system. There may be more than one (1) disconnect switch. Turn
off auxiliary heater power if applicable. Electrical shock can cause personal
injury or death.
INTRODUCTION
The VERT-I-PAK is ETL and c-ETL listed and is available in the cooling/
electric heating sizes shown in Table 1. The VERT-I-PAK units are
approved for upflow installations. They are designed to be installed in
closets.
The VERT-I-PAK is a self-contained unit. All components including outdoor
coil, compressor, and refrigerant tubing are located in a single package.
The units are already piped, charged, and wired. Refer to Figure 2 for basic
unit dimensions.
P.O. BOX 1540 • San Antonio, TX 78295
Ph: 210-357-4400 • FAX: 210-357-4485
www.friedrich.com
SELF-CONTAINED INDOOR AIR CONDITIONER / HEAT PUMP
Table 1 - Unit Sizes And Available Electric Heat
VEB42, VHB42, VEB48, VHB48
UNIT
COOLING
HEATING
AVAILABLE
SIZE
BTUH
BTUH AT 47ºF
KW
V(E,H)B42
42,000
41,000
10 or 15
V(E,H)B48
48,000
47,000
15 or 20