background image

Comfort & 

Dehumidification

• Removes up to 3.2 pts./hr. of moisture 

in cool mode to improve comfort and 
reduce the chance of mold and mildew 
growth

• Intuitive unit controls are easy to 

operate and operate either set point or 
room temperature

• Owner-con

fi

 gurable 'Constant Fan' 

mode

• 'Instant Heat' heat pump mode 

quickly heats a room to the desired 
temperature for increased comfort

• 'Even-heat Monitoring' checks room 

temperature and automatically adds 
heat boost if necessary

• The digital control panel will 

automatically run the fan to brie

fl

 y 

sample the room temperature every 
nine minutes to ensure desired 
conditions are maintained

Maintenance & 

Installation Features

• Universal heaters with heat capacities 

determined by the power cords; 
achieve up to 48 PTAC SKUs with 16 
units by changing the power cord size

• Remote thermostat pop-out wiring 

module allows easier wiring and unit 
changeout without rewiring thermostat

• May be installed 

fl

 ush with the 

fl

 oor

• Reversible indoor air louvers

• Condensate disposal system

• Improved weather barrier

• Emergency heat override ensures heat 

mode operation even in the unlikely 
event of compressor failure

• Modular product design ensures easy 

access to key components for cleaning 
and repairs– including washable, lift-
out air 

fi

 lters

• Depth of front is 7 3/4 inches which 

preserves indoor 

fl

 oor space

Energy Usage & 

Management

• Energy management system 

compatible

• Control with a wired or wireless 

digital wall thermostat

Health & IAQ

• Fresh air damper to bring in fresh 

outside air when desired

• Two, easy-access washable, 

antimicrobial air 

fi

 lters

• Up to 3.2 pts./hr. dehumidi

fi

 cation

Sound Reduction 

Technology

• Two permanently lubricated fan 

motors for added durability and 
reduced sound levels indoors

• Quiet, ef

fi

 cient rotary compressor 

mounted with vibration isolators 
to keep the compressor running 
smoothly and quietly

• High-density insulation blanket blocks 

outdoor noise

Durability

• Faultless sure-hold front cover system 

securely attaches the front each time

• Random compressor restart protects 

electrical systems from overload when 
power is restored

• Quiet, ef

fi

 cient rotary compressor 

mounted with vibration isolators 
to keep the compressor running 
smoothly and quietly

• Steel base pan and sleeve

• Stainless steel outdoor end plates

• Room freeze protection

5X THE SURF

ACE AREA =

 

WIDER AIR P

ATH

The tangential blower wheel has 5x the 
surface area of blowers used by other PTACs. 
It creates a wide path air 

fl

 ow that reaches the 

furthest corner of the guest room.

MORE STANDARD FEATURES

ents

Protects the outdoor coil against 
deterioration and extends the life of 
the unit especially in harsh coastal 
environments.

PDXWS WALL SLEEVE 
DIMENSIONS:

16" H x 42" W x 13 3/4" D

FRONT COVER DIMENSIONS:

16" H x 42" W x 7 3/4" D

CUT OUT DIMENSIONS:

16 1/4"  x 42 1/4"

2 YR. 

FULL WARRANTY

PARTS AND LABOR

5 YR. 

LIMITED WARRANTY

Outdoor coil has 
Diamonblue™ 
advanced corrosion 
protection and 
stainless steel 
endplates

Quiet, ef

fi

 cient rotary 

compressor mounted on 
large vibration isolators

Durable, powder 
coat paint 

fi

 nish

Remote thermostat quick-connect wiring module

*Effective 01/01/13. See warranty documentation for full details.

19

Summary of Contents for Vert-I-Pak VEA09K

Page 1: ...PTACs DUCTLESS SPLIT SYSTEMS VERTICAL PTACs THE EXPERTS IN ROOM AIR CONDITIONING SPECIALTY AIR CONDITIONERS www friedrich com...

Page 2: ...ANT LINES INDOOR UNIT converts warm indoor air to cold indoor air conditioning and dehumidifying the room while filtering the air Unit is mounted high on the wall OUTDOOR CONDENSER transfers heat to t...

Page 3: ...it to condition one area or a multizone system for precise comfort from one system in up to four different zones Up to 4 wall mounted indoor units with a single outdoor condensing unit ZONE 1 ZONE 2 Z...

Page 4: ...off in unoccupied rooms Each system can adjust capacity and cooling output to provide only the amount of cooling needed at a given time For example an 18000 Btu system will operate even more efficient...

Page 5: ...e of 25 40 in performance due to leaks cracks or disconnections in ductwork No ductwork means that ductless systems do not experience duct loss ZONE COOLING FLEXIBILITY Independently condition up to 4...

Page 6: ...tte Installation On the wall On the wall On the ceiling or low against the wall On the ceiling Flush with ceiling Cool only Y N N N N Heat pump Y Y Y Y Y 115 volt models Y N N N N Inverter compressor...

Page 7: ...F MW24C3G MW30C3G MW36C3G Comfort Convenience LCD wireless remote for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds high medium low quiet plus autofa...

Page 8: ...e for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds cooling or heating high medium low quiet plus autofan Multiple operating modes including Auto coo...

Page 9: ...mfort Convenience LCD wireless remote for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds cooling or heating high medium low quiet plus autofan Multipl...

Page 10: ...even distribution of air throughout the room Auto shut flaps close when unit is off for a sleeker appearance Auto restart after power interruptions Auto changeover Low temperature operation to 0 F Se...

Page 11: ...in pump WIRED CONTROLLER USED WITH DWC 18000 Btu and larger models and all multizone systems 7 day programmable ON OFF timer controls up to 16 units individu ally or by zones Wired wall mounted contro...

Page 12: ...WER SOURCE 115 60 1 115 60 1 230 208 60 1 230 208 60 1 230 208 60 1 230 208 60 1 MIN AMPACITY A 15 15 16 14 22 22 COOLING WATTS W 640 920 1730 2400 3240 3880 MAX TD FUSE BREAKER A 25 25 20 20 30 30 RE...

Page 13: ...G OUTDOOR dB A 46 49 47 54 OPERATING RANGE HEATING F 14 115 5 75 14 115 5 75 14 115 5 75 0 115 0 75 EST YEARLY OPERATING COST 54 73 111 141 ELECTRICAL DATA POWER SOURCE 230 208 60 1 230 208 60 1 230 2...

Page 14: ...ND RATING OUTDOOR dB A 52 52 52 52 OPERATING RANGE HEATING F 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 EST YEARLY OPERATING COST 128 152 152 184 312 ELECTRICAL DATA ALL INDOOR UNITS RECEIVE POWE...

Page 15: ...27 29 33 37 33 39 42 46 30 34 39 42 SOUND RATING OUTDOOR dB A 52 52 52 52 52 OPERATING RANGE HEATING F 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 EST YEARLY OPERATING COST 216 254 254...

Page 16: ...WATTS W 2250 4220 2100 MAX TD FUSE BREAKER A 20 30 20 REFRIGERATION SYSTEM REFRIGERANT R410A R410A R410A COMPRESSOR TYPE Inverter Twin Rotary Inverter Twin Rotary Inverter Twin Rotary CONNECTIONS Fla...

Page 17: ...nar airflow Ultra quiet two motor design With separate indoor and outdoor motors the indoor motor can run at slower speeds which reduces sound levels indoors QUIET WITH POWERFUL AIR FLOW And outstandi...

Page 18: ...r steel inner wall and foam construction decreases thermal transfer and energy loss Condensate removal system uses slinger ring technology to cool the coil and increase efficiency Desk control ready a...

Page 19: ...r damper to bring in fresh outside air when desired Two easy access washable antimicrobial air filters Up to 3 2 pts hr dehumidification Sound Reduction Technology Two permanently lubricated fan motor...

Page 20: ...red or unit powered Features backlit display and multiple configuration modes WRT1 Wireless single stage wall mounted digital thermostat with two fan speeds Features backlit display and multiple confi...

Page 21: ...ate or to the rear wall sleeve flange for external draining Recommended for all units to remove excess condensate 10 pack LATERAL DUCT ADAPTER PDXDAA Attaches to the Friedrich PTAC PTHP unit to direct...

Page 22: ...Charge Oz 23 63 24 69 33 51 33 51 35 27 35 98 38 10 40 21 Dimensions with Packaging In 19 75 x23 x43 5 all models PDH Series Model PDH07K PDH07R PDH09K PDH09R PDH12K PDH12R PDH15K PDH15R PERFORMANCE...

Page 23: ...4 1 Branch Circuit Fuse Amps 15 15 15 20 20 30 30 15 20 30 Electric Heat Data Model PDE12K0 PDE PDH12K PDE PDH12R Heater Watts 0 Kw 2000 1635 3000 2450 5000 4090 2000 3000 5000 Voltage 230 208 230 208...

Page 24: ...Chassis is screwed into the wall plenum Metal on metal contact transfers vibration increasing operating noise under typical conditions Noise is transferred through the walls and into the room 2 No in...

Page 25: ...icated motor for low maintenance and maximum efficiency Engineered drain pan won t rust eliminating the risk of unsightly rust stains from condensation on the building exterior Standard safety power d...

Page 26: ...trolled Heat and cool Duct air specifically where it s needed not just on the outside wall 2 speed fan with constant fan option A better choice than whole building solutions ADVANTAGES INCLUDE Lower i...

Page 27: ...AWP1 8 VPAWP1 14 Two part sleeve that telescopes in and out Sits inside the exterior wall penetration VPAWP1 8 telescopes from 5 1 2 8 VPAWP1 14 telescopes from 8 14 DIMENSIONS 24 1 8 W x 30 3 8 H CUT...

Page 28: ...5 0 2 5 3 4 5 0 2 5 3 4 5 0 2 5 3 4 5 0 7 5 10 0 HEAT PUMP DATA HEATING Btu 8500 8000 10800 10600 16000 15000 20000 19500 COP 47F 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 HEATING POWER W 830 811 1055 1035 1560...