FRIEDRICH ENGINEERED FOR QUIETER PERFORMANCE.

Large, tangential fan generates powerful, quiet airflow.

Improved air distribution 

for better comfort

Tangential blower wheel has nearly 

5x the surface area of a typical fan 
used on other PTACS. The result 
is more uniform air

fl

 ow over a 

wider path for faster, more even air 

distribution throughout the room 
and improved sound levels. 

Air is blown over the entire length 
of the tangential wheel into the 

room in a uniform laminar air

fl

 ow. 

Ultra quiet, 

two motor 

design

With separate 
indoor and outdoor 
motors, the indoor 
motor can run 
at slower speeds 
which reduces 
sound levels 
indoors.

QUIET WITH 

POWERFUL 

AIR FLOW.

And outstanding ef

fi

 ciency

Friedrich PTACs are designed for 
quiet operation with maximum 
comfort and dependable 
performance.

NEW

WRT1
Wireless thermostat 
for simpler, flexible 
placement

Friedrich has a  
one-tier model 
line up, so you’ll 

fi

 nd more premium 

features standard 
on each and every 
Friedrich PTAC.

PTAC

Electric Heat

COOLING
7700-15000 Btu

Up to 12.2 EER

ELECTRIC HEAT
6800-17000 Btu

PTAC

Heat Pump

COOLING
7700-14500 Btu

Up to 12.2 EER

HEATING
6300-13300 Btu

COOL & HEAT  

17

Summary of Contents for Vert-I-Pak VEA09K

Page 1: ...PTACs DUCTLESS SPLIT SYSTEMS VERTICAL PTACs THE EXPERTS IN ROOM AIR CONDITIONING SPECIALTY AIR CONDITIONERS www friedrich com...

Page 2: ...ANT LINES INDOOR UNIT converts warm indoor air to cold indoor air conditioning and dehumidifying the room while filtering the air Unit is mounted high on the wall OUTDOOR CONDENSER transfers heat to t...

Page 3: ...it to condition one area or a multizone system for precise comfort from one system in up to four different zones Up to 4 wall mounted indoor units with a single outdoor condensing unit ZONE 1 ZONE 2 Z...

Page 4: ...off in unoccupied rooms Each system can adjust capacity and cooling output to provide only the amount of cooling needed at a given time For example an 18000 Btu system will operate even more efficient...

Page 5: ...e of 25 40 in performance due to leaks cracks or disconnections in ductwork No ductwork means that ductless systems do not experience duct loss ZONE COOLING FLEXIBILITY Independently condition up to 4...

Page 6: ...tte Installation On the wall On the wall On the ceiling or low against the wall On the ceiling Flush with ceiling Cool only Y N N N N Heat pump Y Y Y Y Y 115 volt models Y N N N N Inverter compressor...

Page 7: ...F MW24C3G MW30C3G MW36C3G Comfort Convenience LCD wireless remote for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds high medium low quiet plus autofa...

Page 8: ...e for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds cooling or heating high medium low quiet plus autofan Multiple operating modes including Auto coo...

Page 9: ...mfort Convenience LCD wireless remote for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds cooling or heating high medium low quiet plus autofan Multipl...

Page 10: ...even distribution of air throughout the room Auto shut flaps close when unit is off for a sleeker appearance Auto restart after power interruptions Auto changeover Low temperature operation to 0 F Se...

Page 11: ...in pump WIRED CONTROLLER USED WITH DWC 18000 Btu and larger models and all multizone systems 7 day programmable ON OFF timer controls up to 16 units individu ally or by zones Wired wall mounted contro...

Page 12: ...WER SOURCE 115 60 1 115 60 1 230 208 60 1 230 208 60 1 230 208 60 1 230 208 60 1 MIN AMPACITY A 15 15 16 14 22 22 COOLING WATTS W 640 920 1730 2400 3240 3880 MAX TD FUSE BREAKER A 25 25 20 20 30 30 RE...

Page 13: ...G OUTDOOR dB A 46 49 47 54 OPERATING RANGE HEATING F 14 115 5 75 14 115 5 75 14 115 5 75 0 115 0 75 EST YEARLY OPERATING COST 54 73 111 141 ELECTRICAL DATA POWER SOURCE 230 208 60 1 230 208 60 1 230 2...

Page 14: ...ND RATING OUTDOOR dB A 52 52 52 52 OPERATING RANGE HEATING F 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 EST YEARLY OPERATING COST 128 152 152 184 312 ELECTRICAL DATA ALL INDOOR UNITS RECEIVE POWE...

Page 15: ...27 29 33 37 33 39 42 46 30 34 39 42 SOUND RATING OUTDOOR dB A 52 52 52 52 52 OPERATING RANGE HEATING F 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 EST YEARLY OPERATING COST 216 254 254...

Page 16: ...WATTS W 2250 4220 2100 MAX TD FUSE BREAKER A 20 30 20 REFRIGERATION SYSTEM REFRIGERANT R410A R410A R410A COMPRESSOR TYPE Inverter Twin Rotary Inverter Twin Rotary Inverter Twin Rotary CONNECTIONS Fla...

Page 17: ...nar airflow Ultra quiet two motor design With separate indoor and outdoor motors the indoor motor can run at slower speeds which reduces sound levels indoors QUIET WITH POWERFUL AIR FLOW And outstandi...

Page 18: ...r steel inner wall and foam construction decreases thermal transfer and energy loss Condensate removal system uses slinger ring technology to cool the coil and increase efficiency Desk control ready a...

Page 19: ...r damper to bring in fresh outside air when desired Two easy access washable antimicrobial air filters Up to 3 2 pts hr dehumidification Sound Reduction Technology Two permanently lubricated fan motor...

Page 20: ...red or unit powered Features backlit display and multiple configuration modes WRT1 Wireless single stage wall mounted digital thermostat with two fan speeds Features backlit display and multiple confi...

Page 21: ...ate or to the rear wall sleeve flange for external draining Recommended for all units to remove excess condensate 10 pack LATERAL DUCT ADAPTER PDXDAA Attaches to the Friedrich PTAC PTHP unit to direct...

Page 22: ...Charge Oz 23 63 24 69 33 51 33 51 35 27 35 98 38 10 40 21 Dimensions with Packaging In 19 75 x23 x43 5 all models PDH Series Model PDH07K PDH07R PDH09K PDH09R PDH12K PDH12R PDH15K PDH15R PERFORMANCE...

Page 23: ...4 1 Branch Circuit Fuse Amps 15 15 15 20 20 30 30 15 20 30 Electric Heat Data Model PDE12K0 PDE PDH12K PDE PDH12R Heater Watts 0 Kw 2000 1635 3000 2450 5000 4090 2000 3000 5000 Voltage 230 208 230 208...

Page 24: ...Chassis is screwed into the wall plenum Metal on metal contact transfers vibration increasing operating noise under typical conditions Noise is transferred through the walls and into the room 2 No in...

Page 25: ...icated motor for low maintenance and maximum efficiency Engineered drain pan won t rust eliminating the risk of unsightly rust stains from condensation on the building exterior Standard safety power d...

Page 26: ...trolled Heat and cool Duct air specifically where it s needed not just on the outside wall 2 speed fan with constant fan option A better choice than whole building solutions ADVANTAGES INCLUDE Lower i...

Page 27: ...AWP1 8 VPAWP1 14 Two part sleeve that telescopes in and out Sits inside the exterior wall penetration VPAWP1 8 telescopes from 5 1 2 8 VPAWP1 14 telescopes from 8 14 DIMENSIONS 24 1 8 W x 30 3 8 H CUT...

Page 28: ...5 0 2 5 3 4 5 0 2 5 3 4 5 0 2 5 3 4 5 0 7 5 10 0 HEAT PUMP DATA HEATING Btu 8500 8000 10800 10600 16000 15000 20000 19500 COP 47F 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 HEATING POWER W 830 811 1055 1035 1560...

Reviews: