background image

920-159-03 (11-07)

Printed in the U.S.A.

 

Friedrich Air Conditioning Company 

P.O. Box 1540  

San Antonio, TX 78295 

210.357.4400 

www.friedrich.com

 

VERT-I-PAK

®

  A SERIES 

SINGLE PACKAGE VERTICAL AIR CONDITIONERS 

LIMITED WARRANTY 

 

SAVE THIS CERTIFICATE.  

It gives you specific rights, you may also have other rights which may vary from state to state and province to 

province. 

 

In the event that your unit needs servicing, contact your nearest authorized service center.  If you do not know the nearest service center, 

ask the company that installed your unit or contact us - see address and telephone number above. 

 

To obtain service and/or warranty parts 

replacement, you must notify an authorized FRIEDRICH Air Conditioning Co. service center, distributor, dealer, or contractor of any defect 

within the applicable warranty period. 

 

When requesting service:

 please have the model and serial number from your unit readily available. 

 

Unless specified otherwise herein, 

the following applies:  

FRIEDRICH VERT-I-PAK A SERIES VERTICAL AIR CONDITIONERS AND HEAT PUMPS

 

 

LIMITED WARRANTY - FIRST YEAR (Twelve (12) months from the date of installation). 

Any part found to be defective in the material  

or workmanship will be repaired or replaced free of charge by our authorized service center during the normal working hours; and 

 

LIMITED  WARRANTY  -  SECOND  THROUGH  FIFTH  YEAR  (Sixty  (60)  months  from  the  date  of  installation).  ON  THE  SEALED 

REFRIGERATION SYSTEM.  

Any part of the sealed refrigeration system that is defective in material or workmanship will be repaired or 

replaced free of charge (excluding freight charges) by our authorized service center during normal working hours.  The sealed refrigeration 

system consists of the compressor, metering device, evaporator, condenser, reversing valve, check valve, and the interconnecting tubing. 

 

These warranties apply only while the unit remains at the original site and only to units installed inside the continental United 

States, Alaska, Hawaii, Puerto Rico and Canada. The warranty applies only if the unit is installed and operated in accordance with 

the printed instructions and in compliance with applicable local installation and building codes and good trade practices. For 

international warranty information, contact the Friedrich Air Conditioning Company - International Division. 

 

Any defective part to be replaced must be made available to 

FRIEDRICH

 in exchange for the replacement part.  Reasonable proof must be 

presented to establish the date of install, otherwise the beginning date of this certificate will be considered to be our shipment date plus sixty 

days.  Replacement parts can be new or remanufactured.  Replacement parts and labor are only warranted for any unused portion of the 

unit’s warranty.

  

 

We will not be responsible for and the user will pay for: 

1. Service calls to:   

A) Instruct on unit operation.  B) Replace house fuses or correct house wiring.  C) Clean or replace air filters. D) Remove the unit 

from its installed location when not accessible for service required. E) Correct improper installations. 

 

2.  Parts or labor provided by anyone other than an authorized service center. 

 

3.  Damage caused by: 

A) Accident, abuse, negligence, misuse, riot, fire, flood, or acts of God.  B) Operating the unit where there is a corrosive atmosphere 

containing  chlorine,  fluorine,  or  any  damaging  chemicals  (other  than  in  a  normal  residential  environment).    C)  Unauthorized 

alteration  or  repair  of  the  unit,  which  in  turn  affects  its  stability  or  performance.    D)  Failing  to  provide proper  maintenance  and 

service.  

E

) Using an incorrect power source. 

 F

) Faulty installation or application of the unit. 

 

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of 

this unit.  We have not made and do not make any representation or warranty of fitness for a particular use or purpose and there 

is no implied condition of fitness for a particular use or purpose.  We make no expressed warranties except as stated in this 

certificate.  No one is authorized to change this certificate or to create for us any other obligation or liability in connection with 

this unit.  Any implied warranties shall last for one year after the original purchase date.  

Some states and provinces do not allow 

limitations on how long an implied warranty or condition lasts, so the above limitations or exclusions may not apply to you.  The provisions of 

this warranty are in addition to and not a modification of or subtraction from the statutory warranties and other rights and remedies provided 

by law. 

 

In case of any questions regarding the provisions of this warranty, the English version will govern.  

(10-0

6

)

 

Summary of Contents for VEA24K25 Series

Page 1: ...920 159 03 11 07 VERT I PAK A SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONINGSYSTEM 24 000 BTU h INSTALLATION OPERATION GUIDE...

Page 2: ...ectrical and Thermostat Wiring Diagrams 11 Chassis Operation Fresh Air Door 12 Low Ambient Protection 12 Room Freeze Protection 12 Emergency Heat Override 12 Emergency Heat Operation 12 Service Servic...

Page 3: ...louver should be maintained For major obstructions such as a solid fence wall or other heat rejecting device like a condensing unit a mini mum distance of 72 should be kept 12 24 60 VPAK VPAK VPAK POL...

Page 4: ...I Pak Chassis Specifications Voltage V 230 208 Refrigerant R 22 Chassis Width 23 125 Chassis Depth 23 125 Chassis Height 47 25 Supply Duct Collar 10 Drain Connection 3 4 FPT Min Circuit Amps See Namep...

Page 5: ...grounded Wire Sizing Use recommended wire size given in tables and install a single branch circuit All wiring must comply with local and national codes NOTE Use copper conductors only CAUTION Electric...

Page 6: ...ions 24 5 8 wide x 30 7 8 high VPRG4 Access Panel cutout dimensions 27 wide by 55 3 4 high See Figure 8 Page 10 for proper chassis installation Figure 3 Typical Utility Closet Chassis Shown in Closet...

Page 7: ...ide wall plenum Part A Inside Wall Plenum Part B Wall Plenum Outdoor Louver Installation Rough opening dimension 24 5 8 wide x 30 7 8 high Ensure that the bottom of the plenum is 1 1 2 from the floor...

Page 8: ...tedrainsystemmustbeconnected to one of the two 3 4 FPT connections 3 The remaining connection must be plugged using the 3 4 pipe plug provided and field suppled teflon tape or pipe joint compound 4 Fa...

Page 9: ...the condensate exit location Be sure to use teflon tape or approved pipe sealant on all drain connections and plugs see page 8 C Place the chassis into the closet with the outdoor side facing the wall...

Page 10: ...n the wires through the side hole in the box and under the control components in the box to reach the connection terminal for the wiring 4 Make the wire connections appropriately matching the wires as...

Page 11: ...03 NOTE THE DIAGRAM ABOVE ILLUSTRATES THE TYPICAL THERMOSTAT WIRING SEE THE UNIT CONTROL PANEL FOR THE ACTUAL UNIT WIRING DIAGRAM AND SCHEMATIC CONNECTION TERMINAL Electrical Thermostat Wiring Diagram...

Page 12: ...h Air Door is an intake system The fresh air door is opened via a slide on the front of the chassis located just above the indoor coil Move the slide left to open and right to close the fresh air door...

Page 13: ...heefficiencyofyourVert I Pakandallows lint and dirt to accumulate on the indoor air coil Lint and dirt on the indoor air coil can damage your unit and void the warranty The air filter should be replac...

Page 14: ...coil Fan motor failure Restricted air flow Non condensables in refrigeration system 07 I D coil temperature 30 Deg F for 2 consecutive minutes Alternately flash set point and error code Continue fan o...

Page 15: ...pecial color to match the exterior wall ARCHITECTURAL LOUVER Extruded aluminum louver that attaches to the outdoor section of the wall plenum DIMENSIONS 31 1 16 high x 25 9 16 wide Same as VPAWP1 8 bu...

Page 16: ...n contact the Friedrich Air Conditioning Company International Division Any defective part to be replaced must be made available to FRIEDRICH in exchange for the replacement part Reasonable proof must...

Reviews: