14
ENGLISH
* The feature can be changed according to
the type of model.
<Right side piping>
Connecting pipe
Connecting
cable
Tape
Drain hose
Indoor
Outdoor
Indoor Unit
Drain hose
Indoor Unit
Drain hose
Insulation
(More than 100~300mm
length and 7mm thickness)
Extension
drain hose
CAUTION
If the extension drain hose is routed inside
the room, insulate the hose with an insula-
tion material* so that dripping from sweat-
ing (condensation) could not damage fur-
niture or floors.
• Foamed polyethylene or equivalent is
recommended.
!
CAUTION
Must use the elbow type
(L-Type) conduit
Method:
1. Disassemble bracket
(from indoor unit)
2. Assemble it with conduit
3. Reassemble it with indoor
unit.
!
1
Align the center of the pipes and sufficiently
tighten the flare nut by hand
2
Tighten the flare nut with a wrench
3. When needed to extend the drain hose of
indoor unit, assembly the drain pipe as
shown on the drawing
Indoor unit tubing
Flare nut Pipes
Wrench
Indoor unit tubing
Open-end wrench
(fixed)
Connection
pipe
Flare nut
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Outside Diameter
Torque
mm
inch
kgf·cm
N·m
Ø6.35
1/4
180~250
17.6~24.5
Ø9.52
3/8
340~420
33.3~41.2
Ø12.7
1/2
550~660
53.9~64.7
Ø15.88
5/8
630~820
61.7~80.4
Connecting the installation pipe
and drain hose to the indoor unit.