To operate air conditioner with remote control

NOTE: 

Remote control may vary in appearance.

NOTE: 

Two AAA batteries (included) power the remote control. 

Replace batteries after 6 months of use, or when the remote 
control starts to lose power. 

To turn the air conditioner on or off:

Press POWER.

To select the mode:

To select the fan speed:

Press FAN SPEED for 

Low,

 Medium

 

or

 

High

.

To raise the temperature:

Press the plus button to raise the temperature. Each time you
press or hold the plus button, the temperature will go up 1º until it 
reaches 

90

°F (

32.2

°C).

To lower the temperature:

Press the minus button to lower the temperature. Each time you 
press or hold the minus button, the temperature will go down 1º 
until it reaches 6

0

°F (1

5.5

°C).

To set Timer for a 1- to 24-hour delay before air conditioner 
is turned off (air conditioner must be On):

1.

Press TIMER. Indicator light on air conditioner control panel 
will flash.

2.

Press the plus or minus button to change the delay time from 
1 to 24 hours.

3.

Press TIMER again or wait 10 seconds. Indicator light on air 
conditioner control panel will remain on.

To set Timer to turn on air conditioner, keeping previous 
settings:

1.

Turn off air conditioner.

2.

Press TIMER. Indicator light on air conditioner control panel
will flash.

3.

Press the plus or minus button to ch ange delay time (1 to 
24 hours). 

4.

Press TIMER again or wait 10 seconds. Indicator light on air 
conditioner control panel will remain on.

To set Timer to turn on air conditioner, changing the 
previous settings:

1.

Turn on air conditioner.

2.

Adjust Mode to Cool, Fan Only, or Power Saver.

3.

Adjust Fan Speed to High, Medium

 or Low.

4.

Adjust temperature between 6

0

°F (

15.5

ºC) and 

90

°F (3

2.2 

ºC).

5.

Turn off air conditioner. 

6.

Press TIMER. Indicator light on air conditioner control panel 
will flash.

7.

Press the plus or minus button to change delay time (1 to 
24 hours).

8.

Press TIMER again or wait 10 seconds. Indicator light on air 
conditioner control panel will remain on.

 

Press COOL, FAN or $ SAVER

13

Summary of Contents for CP15F10

Page 1: ... CP15F10A ...

Page 2: ......

Page 3: ...llation on some models 7 Through the Wall Cabinet Installation 9 Complete Installation 10 Air Conditioner Use 11 Starting Your Air Conditioner Digital Control 12 Remote Control Operation 13 Normal Sounds 13 Air Conditioner Care 14 Cleaning the Air Filter r 14 Cleaning the Front Panel 14 Repairing Paint Damage 14 Annual Maintenance 14 Troubleshooting 14 Assistance or Service 15 Warranty 16 1 ...

Page 4: ...technicians should service this equipment R410A systems operate at higher pressures than R22 equipment Appropriate safe service and handling practices must be used Only use gauge sets designed for use with R410A Do not use standard R22 gauge sets Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read ...

Page 5: ...K pan head Phillips screws 2 K ...

Page 6: ...ted in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number nameplate label The model and serial number label is located behind the front panel on the flange below the control panel area Specific electrical requirements are listed in the chart below Follow the requirements for the type of ...

Page 7: ...quipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button w...

Page 8: ......

Page 9: ...and then bottom of right hand curtain housing in top and bottom curtain channels on air conditioner Top view Bottom view 3 Extend right hand curtain outward so you may insert the first screw through the middle hole of the curtain Using 10 x pan head Phillips screw screw curtain to middle hole in air conditioner cabinet NOTE This screw is required to correctly attach curtain top to bottom to the ai...

Page 10: ...7 ...

Page 11: ...1 2 ...

Page 12: ...t and 7 10 x 1 wood screws not provided to attach cabinet to frame NOTE Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and air conditioner 8 Caulk all outside wall openings around cabinet 4 Use a level to check that cabinet is level side to side CompleteInstallation NOTE Handle air conditioner carefully and gently 1 Make sure the free end of the groun...

Page 13: ...and 2 9 5X 3 8 pan head Phillips screws attach front of panel to chassis ...

Page 14: ...us or minus button to change the delay time from 1 to 24 hours 3 Press TIMER or wait 10 seconds Indicator light will remain on To set the Timer delay for a 1 to 24 hour delay until the air conditioner turns on keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light will flash 3 Press the plus or minus button to change the delay time from 1 to 24 hours 4 Press TIMER or wa...

Page 15: ...ol panel will flash 2 Press the plus or minus button to change the delay time from 1 to 24 hours 3 Press TIMER again or wait 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light on air conditioner control panel will flash 3 Press the plus or minus button ...

Page 16: ...on after turning the unit off Wait at least 3 minutes after turning the unit off before trying to restart the air conditioner Cleaningthe FrontPanel 1 Turn off air conditioner 2 Remove the air filter and clean it separately See Cleaning the Air Filter 3 Wipe the front panel with a soft damp cloth 4 Air dry front panel completely Repairing Paint Damage Check once or twice a year for paint damage Th...

Page 17: ...liances during the hottest part of the day The louvers are blocked Install the air conditioner in a location where the louvers are free from curtains blinds furniture etc The outside temperature is below 65 F 18 C Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 65 F 18 C The temperature of the room you are trying to cool is extremely hot Allow e...

Page 18: ...ics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by war government restrictions or restraints strikes material shortages beyond the control of FRIEDRICH or acts of God OBTAINING WARRANTY PERFORMANCE Service will be provided by the FRIEDRICH Aut...

Page 19: ......

Page 20: ...66129903813 1 800 541 6645 ...

Reviews: