background image

 

Friedrich Air Conditioning Company 

www.friedrich.com

 

ROOM AIR CONDITIONERS 

LIMITED WARRANTY

 

 

FIRST YEAR 

 

ANY PART:

  If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from 

date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible 

for service.  Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service 

Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive 

remedy within twelve months from the date of the original purchase. 

 

SECOND THROUGH FIFTH YEAR

 

 
SEALED REFRIGERANT SYSTEM:

  If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser coil, 

evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your 

Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH 

will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System;  

PROVIDED

 FRIEDRICH will not pay the 

cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the Service Agency, 

and the reinstallation charges associated with repair of the Sealed Refrigeration System.  All such cost will be the sole responsibility 

of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase. 

 

APPLICABILITY AND LIMITATIONS:

  This warranty is applicable only to units retained within the Fifty States of the U.S.A., District 

of Columbia, and Canada.  This warranty is not applicable to: 

 

 

1.    Air filters or fuses. 

 

2.    Products on which the model and serial numbers have been removed. 

 

3.   Products which have defects or damage which results from improper installation, wiring, electrical current 

characteristics, or maintenance;  or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication 

of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by  war, 

government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God. 

 

OBTAINING WARRANTY PERFORMANCE:

  Service will be provided by the

 FRIEDRICH Authorized Dealer or Service

 

Organization

 in your area.  They are listed in the Yellow Pages.  If assistance is required in obtaining warranty performance, write to:  

Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540. 

 

LIMITATIONS:  THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES.  Anything in the warranty 
notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY 
SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.  MANUFACTURER EXPRESSLY DISCLAIMS AND 
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR 
IMPLIED WARRANTY. 

 

Performance of Friedrich’s Warranty obligation is limited to one of the following methods: 
 

 

 

1.  Repair of the unit 

 

2.  A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit. 

3.  Providing a replacement unit of equal value 

 

The method of fulfillment of the warranty obligation is at the sole discretion of Friedrich Air Conditioning. 
 

 

NOTE:

  Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of 

consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you. 

 

OTHER:

  This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

 

PROOF OF PURCHASE:

  Owner must provide proof of purchase in order to receive any warranty related services. 

 

All service calls for explaining the operation of this product will be the sole responsibility of the consumer. 

 

All warranty service must be provided by an 

Authorized FRIEDRICH Service Agency

, unless authorized by FRIEDRICH

 

prior to 

repairs being made. 

 (10-08) 

10001 Reunion Place, Suite 500

78216

(800)541-6645

Summary of Contents for CP15F10

Page 1: ... CP15F10A ...

Page 2: ......

Page 3: ...llation on some models 7 Through the Wall Cabinet Installation 9 Complete Installation 10 Air Conditioner Use 11 Starting Your Air Conditioner Digital Control 12 Remote Control Operation 13 Normal Sounds 13 Air Conditioner Care 14 Cleaning the Air Filter r 14 Cleaning the Front Panel 14 Repairing Paint Damage 14 Annual Maintenance 14 Troubleshooting 14 Assistance or Service 15 Warranty 16 1 ...

Page 4: ...technicians should service this equipment R410A systems operate at higher pressures than R22 equipment Appropriate safe service and handling practices must be used Only use gauge sets designed for use with R410A Do not use standard R22 gauge sets Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read ...

Page 5: ...K pan head Phillips screws 2 K ...

Page 6: ...ted in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number nameplate label The model and serial number label is located behind the front panel on the flange below the control panel area Specific electrical requirements are listed in the chart below Follow the requirements for the type of ...

Page 7: ...quipped with a power supply cord required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press TEST listen for click Reset button w...

Page 8: ......

Page 9: ...and then bottom of right hand curtain housing in top and bottom curtain channels on air conditioner Top view Bottom view 3 Extend right hand curtain outward so you may insert the first screw through the middle hole of the curtain Using 10 x pan head Phillips screw screw curtain to middle hole in air conditioner cabinet NOTE This screw is required to correctly attach curtain top to bottom to the ai...

Page 10: ...7 ...

Page 11: ...1 2 ...

Page 12: ...t and 7 10 x 1 wood screws not provided to attach cabinet to frame NOTE Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and air conditioner 8 Caulk all outside wall openings around cabinet 4 Use a level to check that cabinet is level side to side CompleteInstallation NOTE Handle air conditioner carefully and gently 1 Make sure the free end of the groun...

Page 13: ...and 2 9 5X 3 8 pan head Phillips screws attach front of panel to chassis ...

Page 14: ...us or minus button to change the delay time from 1 to 24 hours 3 Press TIMER or wait 10 seconds Indicator light will remain on To set the Timer delay for a 1 to 24 hour delay until the air conditioner turns on keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light will flash 3 Press the plus or minus button to change the delay time from 1 to 24 hours 4 Press TIMER or wa...

Page 15: ...ol panel will flash 2 Press the plus or minus button to change the delay time from 1 to 24 hours 3 Press TIMER again or wait 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light on air conditioner control panel will flash 3 Press the plus or minus button ...

Page 16: ...on after turning the unit off Wait at least 3 minutes after turning the unit off before trying to restart the air conditioner Cleaningthe FrontPanel 1 Turn off air conditioner 2 Remove the air filter and clean it separately See Cleaning the Air Filter 3 Wipe the front panel with a soft damp cloth 4 Air dry front panel completely Repairing Paint Damage Check once or twice a year for paint damage Th...

Page 17: ...liances during the hottest part of the day The louvers are blocked Install the air conditioner in a location where the louvers are free from curtains blinds furniture etc The outside temperature is below 65 F 18 C Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 65 F 18 C The temperature of the room you are trying to cool is extremely hot Allow e...

Page 18: ...ics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by war government restrictions or restraints strikes material shortages beyond the control of FRIEDRICH or acts of God OBTAINING WARRANTY PERFORMANCE Service will be provided by the FRIEDRICH Aut...

Page 19: ......

Page 20: ...66129903813 1 800 541 6645 ...

Reviews: