USED WITH:

LENGTH-FT.

LIQUID

SUCTION

KIT#

All 9000 and 12000 BTU/h
Indoor Units

15

1/4”

3/8”

T32150

35

1/4”

3/8”

T32350

All 18000 BTU/h Indoor Units

15

1/4”

1/2”

T42150

35

1/4”

1/2”

T42350

All MW24Y3F and MW24C3F Units 

15

1/4”

5/8”

T52150

35

1/4”

5/8”

T52350

All 30000 BTU/h Indoor Units and S24YF, 
S36YF and C24YF Units

15

3/8”

5/8”

T53150

35

3/8”

5/8”

T53350

floor/ceiling universal

ceiling suspended

ceiling cassette

PerFOrMAnce rAtInGs

SYSTEM MODEL NO.

S24YF

S36YF

C24YF

INDOOR MODEL

MS24Y3F

MS36Y3F

MC24Y3F

OUTDOOR MODEL

MR24UY3F

MR36Y3F

MR24UY3F

Capacity Cooling

BTU/h

22200

34100

22200

Capacity Cooling Min - Max

BTU/h

5000-27300

8500-36000

5000-27300

Sensible Heat Ratio

0.62

0.67

0.64

Capacity Heating @ 47°F

BTU/h

24200

36400

24200

Capacity Heating Min - Max

BTU/h

5000-29000

9200-42700

5000-29000

Capacity Heating @ 17°F

BTU/h

15000

23400

14600

HSPF

8.5

8.5

8.5

SEER

15.0

14.0

15.0

EER

9.8

8.1

10.6

Moisture Removal

Pts/h

7.4

7.4

6.4

Airflow (Low, Med, High)

CFM

371/436/518

842/977/1089

436/536/618

Sound Rating - Indoor

dB-A

38/43/47

41/45/48

38/43/45

Sound Rating - Outdoor

dB-A

53

54

53

Operating Range COOL 

(HEAT)

°F

0 to 115 

(14-75)

0 to 115 

(14-75)

0 to 115 

(14-75)

eLectrIcAL dAtA

Power Source

230/208-60-1

230/208-60-1

230/208-60-1

Min. Ampacity

A

15.5

23

15.5

Cooling Watts

W

2250

4220

2100

Max. TD Fuse/Breaker

A

20

30

20

reFrIGerAtIOn sYsteM

Refrigerant

R410A

R410A

R410A

Compressor Type

INVERTER

 (Twin Rotary)

INVERTER

 (Twin Rotary)

INVERTER

 (Twin Rotary)

Connections

Flare

Flare

Flare

Liquid Line O.D.

in

3/8

3/8

3/8

Suction Line O.D.

in

5/8

5/8

5/8

Factory Precharge

ft

50

50

50

Max. Line Length

ft

165

165

165

Max. Height Difference

ft

66

98

66

dIMensIOns & WeIGHt

INDOOR UNIT

W x H x D

in

39 x 7 7/8 x 25 3/4

65 3/8 x 9 1/2 x 27 1/2

32 5/8 x 9 5/8 x 32 5/8

Net Weight

lbs

62

106

75

Shipping Weight

lbs

82

134

97

OUTDOOR 
UNIT

W x H x D

in

35 

3

/

8

 x 32 

5

/

8

 x 13

35 

3

/

8

 x 32 

5

/

8

 x 13

35 

3

/

8

 x 32 

5

/

8

 x 13

Net Weight

lbs

141

141

141

Shipping Weight

lbs

154

154

154

Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both ends. Both liquid and 

suction lines are insulated. Line sets can be joined together with field supplied double female connectors. Each system requires one line set for each indoor 

unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system capacity. For example, a M18DYF 

uses 2 line sets for 9,000 btu units, not 1 for the 18,000 btu product.

DRAIN PUMP

USED WITH

DP-36

S36YF

NOTE: All models have low ambient capabilities built-in. Capacity is reduced as 0 degrees Fahrenheit is approached.
NOTE: All R410A models have 1/2˝ UNF 20 thread per inch charging and vacuuming ports. An adapter must be used 

for 1/4˝ gauges. Adapter part number 67270018 is available through Friedrich parts distributors.

Ceiling and Floor/ceiling universal heat pumps

Refrigeration line sets

All models use

environmentally 

friendly R-410A 

refrigerant.

R-410A

Friedrich Air Conditioning Co.  

l  

P.O. Box 1540  

l

  San Antonio, TX 78295-1540  

l  

800.541.6645  

l

  fax 210.357.4480

www.friedrich.com

DSS-10 (6-10)  

Printed in USA

Due to continuing research in new energy-saving technology, specifications are subject to change without notice.

Summary of Contents for C24YF

Page 1: ...DUCTLESS SPLIT SYSTEMS SINGLE and MULTI ZONE WALL MOUNTED FLOOR CEILING UNIVERSAL CEILING CASSETTE and CEILING SUSPENDED...

Page 2: ...d startup 3rd startup 1st shutdown 2nd shutdown Inverter Technology Standard Technology Standard Energy Usage Inverter reaches setpoint faster then adjusts capacity as required to maintain accurate te...

Page 3: ...s lose an average of 25 40 in performance due to leaks cracks or disconnections in ductwork No ductwork means zero duct loss ultra high efficiency delivers directly to the room No dirty air ducts Now...

Page 4: ...600 M30TYF 9300 9300 11800 30400 15 0 11000 11000 14000 36000 M33TYF 9400 11800 11800 33000 15 0 10700 13600 13600 37900 M36TYF1 9100 9100 17000 35200 15 0 9800 9800 18400 38000 M36TYF2 11700 11700 11...

Page 5: ...or ceiling universal heat pump Universal system may be located low against the wall or on the ceiling Features Auto swing louvers up down left right Continuous Air Sweep Auto restart after power inter...

Page 6: ...ht lbs 21 21 26 40 OUTDOOR UNIT W x H x D in 26 x 21 1 4 x 11 3 8 26 x 21 1 4 x 11 3 8 31 1 8 x 22 3 4 x 12 3 8 31 1 8 x 22 3 4 x 12 3 8 Net Weight lbs 55 71 88 97 Shipping Weight lbs 63 78 98 106 PER...

Page 7: ...Net Weight lbs 21 ea 21 ea 21 21 21 ea 21 ea 21 21 ea Shipping Weight lbs 26 ea 26 ea 26 26 26 ea 26 ea 26 26 ea OUTDOOR UNIT W x H x D in 35 3 8 x 32 5 8 x 13 35 3 8 x 32 5 8 x 13 35 3 8 x 32 5 8 x...

Page 8: ...5 8 5 8 Factory Precharge ft 50 50 50 Max Line Length ft 165 165 165 Max Height Difference ft 66 98 66 DIMENSIONS WEIGHT INDOOR UNIT W x H x D in 39 x 7 7 8 x 25 3 4 65 3 8 x 9 1 2 x 27 1 2 32 5 8 x...

Reviews: