ZONE LOCKOUT
This feature, if enabled, prevents a single zone from
triggering an alarm condition more than three times
before the system is disarmed. However, if disabled
there is no limit on the number of times a zone can
trigger an alarm condition.
Default setting: ON
Press ,
The zone 1 LED will illuminate to indicate the current
Zone Lockout status.
LED ON
Zone Lockout enabled
LED OFF
Zone Lockout disabled
Press to change the setting to the opposite state.
Press to save the new setting and return to
programming mode.
Press to return to programming mode without
saving.
ENTRY/EXIT WARNING TONE
Default setting: ON
Press ,
The zone 1 LED will illuminate to indicate the current
status of the Entry/Exit warning tone.
LED ON
Tone enabled
LED OFF
Tone disabled
Press to change the setting to the opposite state.
Press to save the new setting and return to
programming mode.
Press to return to programming mode without
saving.
JAMMING DETECTION
This feature controls the Control Panels RF jamming
detection circuitry, which if enabled, will continuously
scan for radio jamming signals on the system
operating frequency.
Default setting: OFF
Press ,
The zone 1 LED will illuminate to indicate the current
Jamming Detector status.
LED ON
Jamming Detection enabled
LED OFF
Jamming Detection disabled
Press to change the setting to the opposite state.
Press to save the new setting and return to
programming mode.
Press to return to programming mode without
saving.
Note: It is recommended to run the system for 30
days before setting up the jamming detection system
if required.
HARDWIRED SIREN
Default setting: equal to Alarm Duration
Press ,
The zone LED corresponding to the current setting will
illuminate.
1
2 seconds
2
30 seconds
3
1 minute
4
3 minutes
5
5 minutes
6
equal to Alarm Duration
Press the key corresponding to the required Hardwired
output activation period, the corresponding zone LED
will illuminate as the setting is changed.
Press to save the new setting and return to
programming mode.
Press to return to programming mode without
saving.
ZONE OPERATING MODES
Each alarm zone may be programmed to operate in
one of 5 different modes dependant upon the type of
alarm function it is required to perform.
Personal Attack
- used to provide 24 hour monitoring of any Personal
Attack (PA) switches fitted to the system. Activation
of any PA switch will immediately initiate a Full Alarm
condition.