EXTERNAL
CONNECTIONS
The Control Unit incorporates a terminal block for
connection of an external Hard-wired Siren or
Telephone Dialler unit. The connection terminal
block is located inside the Control Panel behind the
front cover.
To access the terminal block, press
, ,
This puts the system into Test Mode and prevents an
alarm occurring. Undo the two fixing screws on the
top edge of the Control Panel and open the front cover.
Before making any connections, ensure that the
memory jumper link P1 is in the ’OFF’ position and
then remove the DC power jack and disconnect the
back-up batteries.
Note: Jumper link P51 should be fitted into the ON
position only if the tamper circuit for a hardwired siren
is used, otherwise it must be in the OFF position.
After making your external connections reconnect the
power supply and Back-up Battery. Then close the
Control Panel cover and tighten the fixing screws on
the top edge of the Control Panel.
Press to leave Test mode and return to Standby.
TESTING THE SYSTEM
INITIAL TESTING
As the system is initially installed it is recommended
that each device is tested in turn as it is installed, (refer
to testing instructions for particular device).
TESTING AN INSTALLED SYSTEM
The Control Panel has a programmed test routine.
You may test the system at any time, however it is
recommended that the system is tested at regular
intervals not exceeding 3 months.
With the system in Standby Mode with the Power
LED ON.
Press , ,
The Arm and Part-Arm LEDs will flash.
The system is now in the Test Mode
Note: After completing all required test functions
press to leave Test mode and return to Standby.
DETECTOR TEST
Before commencing testing please ensure that there
is no movement in any PIR protected area, all
doors/windows protected by Magnetic Contact
Detectors are closed and that all battery covers are
correctly fitted.
Press
Zone LED 1 will illuminate.
Trigger each detector on the system by either walking
into a PIR protected area or by opening a
door/window protected by a Magnetic Contact
detector. As each detector is triggered the Control
Panel will beep and the LED of the zone which the
detector is configured for will be illuminated. The
Tamper switches of devices may also be tested in the
same way in which case the Tamper Led on the
Control Panel will be illuminated.
Press
to exit detector test
18
ESC
ESC
User Access Code
Permanent
12Vdc power
supply output
(100mA max.)
V+
GND
Latching
relay contacts
(Volt-free)
N.O.
C
N.C.
Not Used
GND
B+
GND
TAMP
Switched
12Vdc output for
external Siren
(300mA max.)
GND
OUT
Terminal
Block
Reset
Jumper
Link P1
External Tamper Switch
Jumper Link P51
Tamper circuit
connections for
hardwired siren
Terminal Block Detail
Normally closed
tamper contact
Hardwired
Siren
TAM
PGND
B+
GND
N.C.
C
N.O.
GND
V+
OUT
GND
1
ESC
?
?
?
?
ENTER
User Access Code
?
?
?
?
ENTER