Summary of Contents for Rittal CMC III DK 7030.202

Page 1: ...Assembly and operating instructions CMC III Access Control DK 7030 202...

Page 2: ...o hereafter as Access Control We wish you every success Yours Rittal GmbH Co KG Rittal GmbH Co KG Auf dem Stuetzelberg 35745 Herborn Germany Tel 49 0 2772 505 0 Fax 49 0 2772 505 2319 E mail info ritt...

Page 3: ...the enclosure frame 8 5 3 3 Installation with the provided bracket on a system chassis 9 5 3 4 Installation on a top hat rail 9 5 4 Connection of the Access Control 10 6 Operation 12 6 1 Activating th...

Page 4: ...tuation which may lead to minor injuries if the instructions are not followed Note Identification of situations that can lead to material damage This symbol indicates an action point and shows that yo...

Page 5: ...trol must not be opened The unit does not contain any parts that need servicing Operating the system in direct contact with water aggressive materials or inflammable gases and va pours is prohibited O...

Page 6: ...erves exclusively to mon itor access to a server enclosure It may only be used together with the CMC III Processing Unit Any other use is not permitted The unit is state of the art and built according...

Page 7: ...be disposed of in an environmentally friendly way They consist of the following materials Polyethylene film PE film cardboard Check the unit for any damage that may have oc curred during transport Not...

Page 8: ...included 2 Installation with the provided bracket on a system chassis 3 Installation on a top hat rail using the bracket in cluded along with a spring clip 5 3 1 Installation notes Install the Access...

Page 9: ...bracket on a system chassis The provided bracket is used for installation on a sys tem chassis Place the Access Control on the bracket from above and latch it similar to the installation on the enclos...

Page 10: ...l Legend 4 CAN bus connection 24 V 5 CAN bus connection 24 V 6 Connection for RJ 12 handle 7 Connection for CMC III reader unit The following CAN bus connection cables from the CMC III accessories ran...

Page 11: ...a new sensor is registered on the bus or the CMC III Processing Unit is restarted the Ergoform S electro magnetic handle is released temporarily Status change display on the CAN bus LEDs Continuous gr...

Page 12: ...bus Colour Status Green con tinuously lit Communication via the CAN bus possible Red flash ing Transmission fault Tab 3 LEDs for the CAN bus connection 6 4 Operating the CMC III Processing Unit from t...

Page 13: ...orisations are immediately deleted without a confirmation prompt Note If a transponder card is held in front of the transponder reader again after the access authorisation has been deleted a corre spo...

Page 14: ...le individual access modules for the previously selected reader unit Device Name Specific description of the Access Control or virtual access controller to which the access module to be switched is co...

Page 15: ...Distance between the sensor and the door 1 small 3 large Entering the value 0 deactivates the integral access sensor Closed status and the status is controlled using the Command param eter Delay Time...

Page 16: ...Explanation Status Indicates whether a coded lock or transponder reader has been connected active or not inactive or the reader unit has been deactivated off Tab 13 Displays at KeyPad level 6 6 5 LED...

Page 17: ...using Notepad for this instead of the standard Notepad editor installed under Windows This is available online as freeware Fig 16 access cmc3 file in Notepad The file is structured as follows Lines st...

Page 18: ...of reader units to access codes contain the following entries Parameter Explanation Keypad Serial number of the Access Control or the virtual access controller to which the reader unit is connected w...

Page 19: ...s not used for a long period Rittal recom mends that it be disconnected from the mains power supply and protected from damp and dust 7 2 Disposal Since the Access Control consists mainly of the housin...

Page 20: ...110 x 30 x 40 Operating temperature range 0 C 55 C Storage temperature 45 C 85 C Operating humidity range 5 95 relative humidity non condensing Protection category IP 30 to IEC 60 529 Inputs and outp...

Page 21: ...ce addresses EN 9 Customer service addresses For technical queries please contact Tel 49 0 2772 505 9052 E mail info rittal de Homepage www rittal com For complaints or service requests please contact...

Page 22: ...22 Rittal CMC III Access Control Notes EN...

Page 23: ...Rittal CMC III Access Control 23 Notes EN...

Page 24: ...tware Services RITTAL GmbH Co KG Auf dem Stuetzelberg 35745 Herborn Germany Phone 49 2772 505 0 E mail info rittal de www rittal com www rittal com contact You can find the contact details of all Ritt...