![FRIEDHELM LOH AS 4050.452 Operating Instructions Manual Download Page 8](http://html1.mh-extra.com/html/friedhelm-loh/as-4050-452/as-4050-452_operating-instructions-manual_2332661008.webp)
4 Operating instructions
8
We reserve the right to make technical modifications.
Rittal Crimping machine L8
EN
AS crimping machine L8
Degree of protection
IP 20
Cycle time
approx. 1.0 s
Continuous sound pressure level
≤70 dB(A)
Dimensions (W x D x H)
390 x 330 x 460 mm
Colour
RAL 9003
Weight
31 kg
Interfaces
Touch display
Operating environment
Storage/transport temperature
-25
°C…+55
°C
Ambient temperature
+5
°C…+40
°C
Operating temperature
+10
°C…+45
°C
Max. operating altitude
2000 m above mean sea level
Humidity
50% at 40 °C (without dewing)
90% at 20 °C (without dewing)
Contamination level
2
Pressure safety equipment
85%
…110
%
4
Operating instructions
4.1
Setting up the machine
◼
Read the operating instructions carefully before commissioning the machine.
◼
Deploy the machine only in a dry environment.
Attention!
The electrical data shown on the rating plate must match that of the power grid.
Otherwise, damage can occur to the machine.
Warning!
Electrical shock caused by working on live components!
◼
Disconnect the mains plug and separate the machine from the
pneumatic network.
Note:
◼
Before processing, clean the stranded wires to remove lubricants
(e.g. talcum).
The machine is equipped with a compressed-air maintenance unit (compressed-air
filter and regulating valve). It can be connected directly to the compressed-air sup-
ply.
◼
Connect the mains cable to the machine and to the power supply.