Thermozone AD Corinte A/E - ADCS

6

18

0

35

35

80

40

Ø12

25

Fig 6

Fig 7

360

243

Ø22

Ø10

15

5

10

Fig 5

Summary of Contents for Thermozone AD Corinte A/E

Page 1: ...Thermozone AD Corinte A E ADCS 26 GB 23 SE 29 RU ...

Page 2: ...ADCS 2 Fig 1 150 150 45 100 44 134 40 65 140 140 40 65 150 44 100 134 45 150 Min 180 Min 180 Ø20 2x Ø20 2x M6 M6 Ø30x2 Ø30x2 Upper part of the unit seen from above Bottom part of the unit seen from above Opening Connection hatch ...

Page 3: ...Thermozone AD Corinte A E ADCS 3 1 2 80 60 1 2 60 80 3 Ø22 Cu Fig 2 ...

Page 4: ...Thermozone AD Corinte A E ADCS 4 1 2 3 4 5 6 2 6 7 Fig 3 ...

Page 5: ...Thermozone AD Corinte A E ADCS 5 Fig 4 ...

Page 6: ...Thermozone AD Corinte A E ADCS 6 180 35 35 80 40 Ø12 25 Fig 6 Fig 7 360 243 Ø22 Ø10 15 5 10 Fig 5 ...

Page 7: ...Thermozone AD Corinte A E ADCS 7 1700 2200 1670 2170 75 Ø30 Ø20 3x Left connection Right connection Wall Fig 8 Fig 9 50 75 376 ADCS A E Min 220 mm ADCS W Min 180 mm ADCS A E Min 220 mm ADCS W Min 180 mm ...

Page 8: ...Thermozone AD Corinte A E ADCS 8 Fig 10 SIRe ...

Page 9: ...Thermozone AD Corinte A E ADCS 9 A B C A C B ADCEH Ø8 Ø12 2x 2 alternatives for securing at the top 1 Ø8 for securing at the air curtain 2 ...

Page 10: ...K nr Description HxWxD mm L m SIReB Control system Basic SIReAC Control system Competent SIReAA Control system Advanced SIReRTX 673 09 22 External room temperature sensor 70x33x23 SIReUR 673 09 21 Kit for recessed installation 114x70x50 SIReWTA Clamp on sensor SIReCJ4 Joint piece for two pcs RJ11 4p 4c SIReCJ6 Joint piece for two pcs RJ11 6p 6c SIReCC603 673 09 23 Modular cable RJ11 6p 6c 3 SIReCC...

Page 11: ...s Internal ADCS A ADCSA SIReB1 230V Actuator 230V Transformer 230V 200V 170V 145V 120V 100V N Black Blue Supply 230V C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue L N ...

Page 12: ...Thermozone AD Corinte A E ADCS 12 SIReB1 SIReUB1 SIReB1 SIReUB1 SIReB1 Wiring diagrams AD Corinte A Ambient control options SIRe Basic SIRe Basic Parallel connection ...

Page 13: ...TERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 ROOM SIReC1X C2 X5 C1 X4 ROOM X3 Pot Unit ID SIReB1 N L PE N L PE SIReDC Wiring diagrams AD Corinte A Ambient control options SIReAC Competent ...

Page 14: ...X3 Pot Unit ID SIReB1 N L PE N L PE ACTUATOR SUPPLY Pot Unit ID Pot Unit ID SIReUA1 EXTERNAL SETBACK TEMP ON OFF potential free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 BUS ROOM SIReC1X SIReDC SIReAC Competent Parallel connection ...

Page 15: ... 400 V3 ADCSE 400V3 400V3 SIReB1 230V Actuator 230V Transformer 230V 200V 170V 145V 120V 100V N Black Black Grey Blue Blue Supply 230V C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue L N ...

Page 16: ...230 V3 ADCSE 230V3 230V3 SIReB1 230V Actuator 230V Transformer 230V 200V 170V 145V 120V 100V N Black Black Grey Blue Blue Supply 230V C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue L1L2 ...

Page 17: ...SIReB1 SIReRTX optional SIReUB1 230V X5 C2 X4 C1 X3 ROOM PE N L SUPPLY 230V ACTUATOR 230V SIReB1 SIReRTX optional SIReUB1 X5 C2 X4 C1 X3 ROOM PE N L SUPPLY 230V ACTUATOR 230V SIReB1 230V 230V Wiring diagrams AD Corinte E Electrical control options SIRe Basic SIRe Basic Parallel connection ...

Page 18: ...l free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 ROOM SIReC1X C2 X5 C1 X4 ROOM X3 Pot Unit ID SIReB1 N L PE N L PE SIReDC 230V Wiring diagrams AD Corinte E Electrical control options SIReAC Competent ...

Page 19: ...Y C2 X5 C1 X4 ROOM X3 Pot Unit ID SIReB1 N L PE N L PE ACTUATOR SUPPLY Pot Unit ID Pot Unit ID SIReRTX optional SIReUA1 EXTERNAL SETBACK TEMP ON OFF potential free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 BUS ROOM SIReC1X SIReDC 230V 230V 230V SIRe...

Page 20: ...S potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 BUS ROOM SIReA1X C2 X5 C1 X4 ROOM X3 Pot Unit ID SIReB1 N L PE N L PE BMS INDICATION OUT potential free contact max 3A 230V 1 2 3 4 5 6 13 14 RPM INDICATION 0 10V DC out max 5 mA EXTERNAL HEAT 0 10V DC IN 21 22 SIReOTX HEAT INDICATION 0 10V DC out max 5 mA ACTUATOR SUPPLY SIReUA1 SIReDC 230V Wiring diagrams AD Corinte E...

Page 21: ...61718 19 20 COM 1 COM 2 BUS ROOM SIReA1X BMS INDICATION OUT potential free contact max 3A 230V 1 2 3 4 5 6 13 14 RPM INDICATION 0 10V DC out max 5 mA EXTERNAL HEAT 0 10V DC IN 21 22 SIReOTX HEAT INDICATION 0 10V DC out max 5 mA SIReUA1 C2 X5 C1 X4 ROOM X3 Pot Unit ID SIReB1 N L PE N L PE ACTUATOR SUPPLY C2 X5 C1 X4 ROOM X3 Pot Unit ID SIReB1 N L PE N L PE ACTUATOR SUPPLY C2 X5 C1 X4 ROOM X3 Pot Un...

Page 22: ...ecifications Thermozone AD Corinte A without heat 1 Type Output kW Airflow m3 h Sound level 5 dB A Output motor W Voltage motor V Amper age motor A Length mm Weight kg ADCS17A 0 1400 3000 40 60 670 230V 2 9 1700 73 ADCS22A 0 1800 4000 42 61 990 230V 4 3 2200 95 ADCS25A 0 2050 4500 43 63 1150 230V 5 0 2450 108 ADCS17 is available only for horizontal mounting ADCS25 is available only for vertical mo...

Page 23: ... 7 och 8 2 Montera konsolerna på apparaten med hjälp av insexnyckel och medlevererade M8 skru var Använd Loctite 270 3 ml på skruvar Allmänna anvisningar Läs noga igenom denna bruksanvisning före installation och användning Spara manualen för framtida bruk Garantin gäller endast om Frico montage och bruksanvisning har följts och aggregaten använts såsom däri är beskrivet Användningsområde AD Corin...

Page 24: ...stering av luftström Luftstrålens riktning och hastighet ska juste ras med hänsyn till belastningen på porten Tryckkrafter påverkar luftströmmen så att den böjer av inåt i lokalen vid uppvärmd lokal och kall uteluft Luftströmmen bör där för riktas utåt för att stå emot belastningen Generellt kan sägas att ju större belastning desto större vinkel krävs Lossa med hjälp av insexnyckel de tre skruvarn...

Page 25: ... från någon timmea till ett par dygn I förebyggande syfte är det lämpligt att anläggningen tas i drift kortare stunder under längre använd ningsuppehåll Säkerhet Vid alla installationer av elvärmda produk ter bör jordfelsbrytare 300 mA för brand skydd användas Säkerställ att området kring apparatens insugs och utblåsgaller hålls fritt från ma terial som kan hindra luftströmmen genom apparaten Appa...

Page 26: ...th the unit for mounting on the wall or hanging from the ceiling General instructions Read these instructions carefully before in stallation and use Keep this manual for future reference The guarantee is only valid if the Thermo zone units are used in the manner intended by the manufacturer and in accordance with the Frico installation and maintenance in structions Application area AD Corinte belo...

Page 27: ...g inside the unit with cable ties to prevent it being sucked into the fans or in contact with the heating elements The control system is pre installed in the aircurtain with an integrated control card see fig 8 SIRe is supplied pre programmed with quick release connections Modular cables are connected to the con trol board Base by opening the front plate as shown in Figure 4 and 5 See manual for S...

Page 28: ... to moisture in the heating ele ment When an appliance containing a heater element has not been used for a long period or stored in a damp environment moisture can enter the element This should not be seen as a fault but is simply rectified by connecting the appliance to the mains supply via a socket without a safety cut out so that the moisture can be eliminated from the element The drying time c...

Page 29: ...ки необходимые для эффективной работы завесы Две монтажные скобы для установки на стену или подвески на потолок поставляются в комплекте с завесой Общие положения Внимательно изучите настоящую инструкцию до начала монтажа и эксплуатации Сохраните данную инструкцию для возможных обращений в будущем Гарантия распространяется на установки выполненные и используемые в соответствии с требованиями и пре...

Page 30: ...екоммутированы на напряжение 400В в 3 фазы см стр 10 Плавное изменение скорости вращения вентиляторов завес производится при помощи частотного инвертора FC15M или FC15A Каждый инвертор должен иметь предохранитель на 10А Подключение к устройству автоматического отключения не рекомендуется Электросхемы приведены на страницах 10 12 При использовании другого инвертора не FC15 максимальное значение час...

Page 31: ...охранителей и т д 2 Проверьте уставку термостата и сравните с текущей температурой 3 Включено ли устройство регулирующее нагрев 4 Убедитесь что защита от перегрева не отключила блок нагрева см выше Обслуживание Внимание Отключите центральный выключатель завесы на распределительном щите до проведения обследования или чистки завесы в воздушных завесах с электрическими нагревательными элементами сило...

Page 32: ...нагреваются По избежание перегрева прибора и появления пожарной опасности он не должен покрываться какими либо предметами или материалами Не допускайте чтобы дети без надзора взрослых производили какие либо действия или играли рядом с прибором Гарантийные обязательства распространяются только на приборы использующиеся строго по назначению и эксплуатирующиеся с соблюдением всех требований настоящей...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...Main office Frico AB Box 102 SE 433 22 Partille Sweden Tel 46 31 336 86 00 Fax 46 31 26 28 25 20120221 HH ...