background image

 

 

 

 

 

 

 

 

 

 

Инструкция 
по эксплуатации 

 

Инфракрасный обогреватель FRICO IRCF3000 

 

Цены на товар на сайте:

 

http://www.vseinstrumenti.ru/klimat/obogrevateli/infrakrasnye/frico/ircf3000/

 

Отзывы и обсуждения товара на сайте:

 

http://www.vseinstrumenti.ru/klimat/obogrevateli/infrakrasnye/frico/ircf3000/#tab-Responses

 

Summary of Contents for IRCF3000

Page 1: ...FRICO IRCF3000 http www vseinstrumenti ru klimat obogrevateli infrakrasnye frico ircf3000 http www vseinstrumenti ru klimat obogrevateli infrakrasnye frico ircf3000 tab Responses...

Page 2: ...Infrared heater IRCF 7 SE 9 NO 11 GB 13 DE 15 FR...

Page 3: ...IRCF 2 Fig 1 Fig 2...

Page 4: ...IRCF 3 Fig 3...

Page 5: ...mal design CE compliant Dimensions Type Height mm Length mm IRCF1500 230 490 IRCF3000 375 490 IRCF4500 515 490 IRCF can be angled 1 SE Effekt GB Output NO Effekt FR Puissance DE Abgabe 2 SE Sp nning G...

Page 6: ...WxD mm CBT Timer 155x87x43 S123 Manual switch for 1 2 3 output steps 72x64x46 T10 Electronic thermostat with concealed knob 80x80x31 TK10 Electronic thermostat with visible knob 80x80x31 KRT1900 Capil...

Page 7: ...0V IRCF 400V 0 X X X X X X 3 2 1 1 3 3 3 2 3 S123 IRCF 400V IRCF 400V IRCF 400V L 230V N L1 L2 L3 N 0 X X X X X X 3 2 1 1 3 3 3 2 3 S123 Thermostat 400V Wiring diagrams IRCF Internal wiring diagrams C...

Page 8: ...rmas n s av v rmestr lar b de framifr n och bakifr n I f rpackningen medf ljer en konsol f r montering p v gg Kontrollera att v ggen r stabil och att skruvarna f r fullt f ste Se till att v rmestr ln...

Page 9: ...Det fria avst ndet till br nnbart material i str lriktningen m ste vara minst 1 m Underh ll Vid allt underh ll ska str mf rs rjningen till apparaten vara fr nkopplad Apparaten har inga r rliga delar s...

Page 10: ...iktige merknader m tas til etterretning Varmestr leren skal alltid installeres horisontalt og bare ved hjelp av de medf lgende brakettene Varmestr leren m ikke plasseres like under en stikkontakt Pass...

Page 11: ...erfor sv rt lite vedlikehold Det er imidlertid n dvendig sjekke om det har samlet seg mye st v smuss p reflektoren eller lampen St vansamling kan f re til overoppheting og forkortet driftstid for lamp...

Page 12: ...ernatives chains and S hooks needed for such installations are to be purchased separately Following important notes must be followed The heater should always be installed horizontally and only by usin...

Page 13: ...erefore very little maintenance is required other than to ensure that there is no excessive build up of dust dirt on the reflector or lamp as this can cause overheating and premature lamp failure To c...

Page 14: ...rsp rt eine Person wenn von zwei Seiten geheizt wird In der Verpackung befindet sich eine Wandhalterung Sicherstellen dass die Wand stabil ist und dass die richtigen Schrauben verwendet werden Sichers...

Page 15: ...en direkte Umgebung nicht mit starkem Staub Schmutz bedeckt ist Dies kann zu einer berhitzung f hren Vor dem Heizstrahler ist aus Sicherheitsgr nden immer ein Mindestanstand von 1 Meter zu brennbaren...

Page 16: ...nce des deux directions Une console murale est fournie dans le paquet S assurer de la stabilit du mur et veiller utiliser des vis adapt es S assurer que l appareil est dirig vers l aire chauffer voir...

Page 17: ...ra ner une surchauffe L metteur doit tre install en veillant toujours ce que sa face avant soit loign e des substances inflammables en respectant une distance de s curit d au moins 1 m Entretien Lors...

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ...v nl Netherlands www fricobv nl For latest updated information see www frico se United Kingdom Frico Limited Tel 44 0 121 322 0854 72 Cheston Road Fax 44 0 121 322 0858 B7 5EJ info uk frico se UK Birm...

Reviews: