background image

PA1508-NA

10

EN

Maintenance 

 Since fan motors and other components are 
maintenance free, no maintenance other than 
cleaning is necessary. The level of cleaning 
can vary depending on local conditions. 
Undertake cleaning at least twice a year. Inlet 
and exhaust grilles, impeller and elements 
can be vacuum cleaned or wiped using a 
damp cloth. Use a brush when vacuuming 
to prevent damaging sensitive parts. Avoid 
the use of strong alkaline or acidic cleaning 
agents. 
 

Overheating  

The air curtain unit with electric heater is 
equipped with an overheat protector. If it is 
deployed due to overheating, reset as follows: 
1. Disconnect the electricity with the fully 

isolated switch. 

2. Allow the electrical coil to cool. 
3. Determine the cause of overheating and 

rectify the fault. 

4. Once the overheat protector has cooled down 

the unit can be started again. 

Trouble shooting  

If the fans are not working or do not blow properly, 
check the following: 

•  The functions and settings of the built-in 

control system. 

•  That the intake grille is not dirty.  

If there is no heat, check the following: 

•  The functions, internal sensor and settings 

of the built-in control system. 

  

For units with electrical heating, also check the fol-
lowing:

•  Power supply to electric heater coil; check 

fuses and circuit-breaker (if any).

•  That the overheat protection for the motors 

has not been deployed.

 
If the fault cannot be rectified, please contact 
a qualified service technician. 

Safety  

• 

For all installations of electrically heated 
products should a residual current circuit 
breaker 300 mA for fire protection be used.

 

• 

Keep the areas around the air intake 
and exhaust grilles free from possible 
obstructions!

• 

The unit must not be fully or partially 
covered as overheating can result in a fire 
risk! 

• 

This appliance can be used by children 
aged from 8 years and above and persons 
with reduced physical, sensory or 
mental capabilities or lack of experience 
and knowledge if they have been given 
supervision or instruction concerning 
use of the appliance in a safe way and 
understand the hazards involved. Children 
shall not play with the appliance. Cleaning 
and user maintenance shall not be made 
by children without supervision. 

 

• 

Children of less than 3 years should be 
kept away unless continuously supervised. 

• 

Children aged from 3 years and less than 8 
years shall only switch on/off the appliance 
provided that it has been placed or 
installed in its intended normal operating 
position and they have been given 
supervision or instruction concerning 
use of the appliance in a safe way and 
understand the hazards involved. 

• 

Children aged from 3 years and less 
than 8 years shall not plug in, regulate 
and clean the appliance or perform user 
maintenance.  

CAUTION — Some parts of this product can 
become very hot and cause burns. Particular 
attention has to be given where children and 
vulnerable people are present. 

Packaging

Packaging materials are chosen with 
consideration to environment and are 
therefore recyclable.  
 

Handling of product at end of working life

This product may contain substances 
necessary for functionality of product but 
potentially dangerous for the environment. 
The product should not be disposed 
mixed with general household waste but 
delivered to a designated collection point for 
environmental recycling. Please contact local 
authority for further details of your nearest 
designated collection point. 

Summary of Contents for 161048

Page 1: ...PA1508 NA 9 GB 11 FR Original instructions...

Page 2: ...f pictures For translation of the English texts used see the respective language pages GB Les pages de pr sentation contiennent principalement des images Pour la traduction des textes en anglais consu...

Page 3: ...PA1508 NA 3 Dimensions 55 390 67 70 25 25 154 167 790 Ref Metric mm Imperial in A 790 31 1 B 390 15 4 C 55 2 2 D 167 6 6 E 154 6 1 F 70 2 8 G 67 2 6 H 25 1 0 A B C D E F G H H...

Page 4: ...B Mounting and installation Fig 1 Mounting bracket Fig 2 Open the unit PH2 PH2 300 300 730 5 5 3x A 14 5 5 683 Ref Metric mm Imperial in A 730 28 7 B 683 26 9 C 300 11 8 D 14 5 0 6 E 5 5 0 2 F 5 0 2...

Page 5: ...PA1508 NA 5 Minimum distance Fig 3 Minimum distance 100 50 50 50 25 A Flammable material A Ref Metric mm Imperial in A 500 19 7 B 100 3 9 C 50 2 0 D 25 1 0 C C C B D...

Page 6: ...PA1508 NA 6 PA1508 NA C C C L M Hi Lo N 1 2 3 4 a e 5 PA1508E04 02 NA 161226 2 5 kW 2 5 kW 0 1 2 1 2 3 a OFF 0 4 kW 3 4 e 5 PA1508E04 NA 0 1 2 OFF 0 3 PA1508E02 NA 1 5 kW 1 5 kW 2 5 kW...

Page 7: ...50 13 208V 12 32 17 PA1508E04 NA 9 13 200 50 19 208V 18 32 17 1 Sound pressure LpA Conditions Distance to the unit 16 ft Directional factor 2 Equivalent absorption area 2153 ft At highest airflow 2 FL...

Page 8: ...er l unit ou d en effectuer l entretien L installation ou l entretien de l unit doivent tre effectu s par un technicien qualifi seulement L unit ne doit pas tre install e et utilis e l ext rieur ou da...

Page 9: ...to the opening as possible Minimum distance from outlet to floor is 1800 mm 70 9 in For other minimum distances see fig 3 Bracket is supplied for wall or ceiling mounting The unit can be tilted for op...

Page 10: ...ound the air intake and exhaust grilles free from possible obstructions The unit must not be fully or partially covered as overheating can result in a fire risk This appliance can be used by children...

Page 11: ...0 06 26 HH KG Main office Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contac...

Reviews: