V. Dismantling of the equipment

• Loosen twist grip knob and

remove scraper from pipe.

• In order to prevent injuries or

scraper damage, the blade
housing should be moved up to
the front plate on completion.

VI. Preparing the fusion process

• Remove the swarf.

• Check scraping result.

If marking has not been completely
removed, the scraping process has
to be repeated from Point III.

• Apply a chamfer (about 0.08" –

0.11") at the end of the pipe
using a hand held scraper.

• Clean the pipe before fusion

using PE cleaner with an
absorbent, non-fibrous and
undyed paper.

•  Processing the FRIALEN

®

/

FRIAFIT

®

 -coupler takes place

according to the installation
instructions.

Attention!
The scraper must be kept clean
and dry and always stored in its
transporting case.

Summary of Contents for FWSG 710 L

Page 1: ...1 1 Operating Instructions Scraper Tool FWSG 710 L Technical Equipment...

Page 2: ...e pipe surface along the entire length of the coupler or half of it Scraping the entire length of the coupler is required when a slide over coupler is employed Only half the coupler up to where insert...

Page 3: ...oyment of slide over couplers I Preparation Remove obvious dirt particles from the pipe surface to be scraped using for example a clean grease free piece of cloth Determine length of area to be scrape...

Page 4: ...e housing roughly to relevant dimension marking Picture 2 The blade housing will end up on the left of the marking The position of the blade hous ing will be fine tuned by turning the roller handle un...

Page 5: ...ing carriage upwards until it is in contact with the pipe wall Picture 3 The supporting arm of the clamping carriage should be roughly parallel to the pipe wall Tighten twist grip knob Picture 6 until...

Page 6: ...g result If marking has not been completely removed the scraping process has to be repeated from Point III Apply a chamfer about 0 08 0 11 at the end of the pipe using a hand held scraper Clean the pi...

Page 7: ...e equipment or parts which wear out prematurely due to their environment sand soil etc The tool must be protected from dirt Operational safety The scraper tool FWSG 710 L is based on quality managemen...

Page 8: ...FRIATEC PE ELECTROFUSION SYSTEMS Technical Plastics Division 426 Fairforest Way Greenville SC 29607 Tel 864 286 8800 Fax 864 234 2060 www friatecusa com E Mail thoeng ipexinc com 2062 1 USA Stand 17 0...