910 mm
36”
TDR-ac Installation
Page 9
Service Manual TDRac
PKII
form 9120931 rev. 11/2017
Prior to installation, test the electrical service to assure that it agrees with the specifications on the
machine data plate located on the right side panel near the controls. The connecting cable for the
unit must be equipped with an approved plug connection. If use is to be made of a permanent con-
nection, the connecting cable must be connected to a manual on/off switch that is installed near
the unit in a clear visible manner.
ELECTRICAL SUPPLY
IMPORTANT:
Make sure you lea-
ve sufficient space around the ro
-
tisserie to easily remove or insert
the rotor. If the base has (rotating)
wheels, the floor on which it rests
must be level.
LOCATION
The oven must be installed on a level surface. The installation location must allow adequate clea-
rances for servicing and proper operation.
The unit must be connected according to one of the the figures below.
1
2
3
4
5
6
N
L1
1
2
3
4
5
6
L2
L1
L3
N
1
2
3
4
5
6
L2
L1
L3
400 V, 3N ~ 50...60 Hz
200 V - 230 V, 1N ~ 50...60 Hz
200 V - 230 V, 3 ~ 50...60 Hz
FACTORY
DEFAULT !
EUROPEAN MODELS
FACTORY
DEFAULT !
AMERICAN MODELS