Fri-Jado STG7 P Installation Manual Download Page 18

Fri-Jado Inc. • 180 Kehoe Blvd. • Carol Stream, Ill. 60188 • USA • tel. 630-784-3469 • fax 630-784-1650  • toll free 877-FRI-JADO • [email protected] • www.frijado.com

Summary of Contents for STG7 P

Page 1: ...erform all the procedures in this manual This manual is not intended to be all encompassing If you have not attended a training for this product you should read in its entirety the repair procedure yo...

Page 2: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 Page 2 EMPTY PAGE...

Page 3: ...pallet 5 Location 6 Connecting the rotisserie 6 Electrical supply 6 Gas connection 7 Gas pressure and orifices 7 Gas inlet pressure 7 Gas technical data 8 Gas consumption 9 Gas block Honeywell type V...

Page 4: ...rotisserie ovens suitable for G 20 25 natural gas STG 7 Oven with seven spits 28 to 35 chickens All of the information illustrations and specifications contained in this manual are based on the lates...

Page 5: ...am in the memory and make a test run on 482 F Give instructions to the operator UNPACKING THE UNIT Immediately after unpacking the oven check for possible shipping damage If the rotisserie is found to...

Page 6: ...s installed near the unit in a clear visible manner ELECTRICAL SUPPLY For a 1 phase 208 V circuit with neutral the unit must be connected according to the figure below IMPORTANT Make sure you leave su...

Page 7: ...gasline after leveling Gas supply line must be at least the equivalent of 1 2 12 7 mm iron pipe Make sure the pipes are clean and free of obstructions dirt and piping compound Note After the piping h...

Page 8: ...DATA GAS TECHNICAL DATA STG 7 GAS PAGE 1 1 Date 01 02 2009 Gas type Inlet pressure inch wc Inlet pressure mbar min pressure Qn Hi inch wc min pressure Qn Hi mbar Consumption cfm Consumption m3 h G20 8...

Page 9: ...e In order to measure loosen the screw on inside of tube Outlet or burner pressure Measuring tube of gas going into gas mixture blower In order to measure loosen the screw on inside of tube You can us...

Page 10: ...Natural gas O2 ref 3 0 CO2 max 11 7 5 2 Oxigen 8 8 CO2 1 33 Lambda 5 ppm CO 0 01 GI 26 7 qR 73 efficiency 130 F dew point 54 C 713 F Exhaust gas temp 378 C 74 F Ambient temp 23 C The 2 most important...

Page 11: ...ge to the conduit during cleaning maintenance and service operations A tether bracket as shown on the drawing below is provided with the base or stacking kit Based on the routing of the flexible condu...

Page 12: ...n in the oven Refer to ANSI NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations latest edition The STG 7 produces about 350 cf water vapor per cycle When plac...

Page 13: ...ccord ing local state or national regulations First remove the right side panel according the service manual Check for gas leaks and or bad connections of the gas supply inside and outside Check the g...

Page 14: ...g the STG 7 Description belonging to the lables on the drawings Label Description 1 Power cable length 70 2 Exhaust opening 3 Space between a rotisserie and a wall or ceiling 4 Location for socket 5 G...

Page 15: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 INSTALLATION DRAWINGS Page 15 Placing and connecting the STG 7 on base...

Page 16: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 Page 16 EMPTY PAGE...

Page 17: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 Page 17 EMPTY PAGE...

Page 18: ...Fri Jado Inc 180 Kehoe Blvd Carol Stream Ill 60188 USA tel 630 784 3469 fax 630 784 1650 toll free 877 FRI JADO us info frijado com www frijado com...