![Fri-Jado MD 60 Hot Service Manual Download Page 15](http://html1.mh-extra.com/html/fri-jado/md-60-hot/md-60-hot_service-manual_2331986015.webp)
Page 15
ELECTRICAL TESTS AND SERVICE PROCEDURES
Service Manual Multi Deck 60 UK form 9123765 rev. 12/2008
WARNING:
Disconnect the electrical power to the machine at the main cir
-
cuit box. Place a tag on the circuit box indicating the circuit is being serviced.
Note: When testing the resistance of the element remove the wiring.
ElECTRICAl TESTS AnD SERvICE PRoCEDuRES
HEATING ELEMENT TEST
Type
Wattage/voltage
Resistance Ω -5% + 10%
Current A
MD 60 with glass door
1400 / 240
41.2
5.8
ADjUSTING DANFOSS EKC 102A THERMOSTAT
Note: In order to adjust the thermostat, first remove the thermostat according prior proce-
dure.
Changing set point
1. Press the middle button until the temperature value is shown.
2. Change value with upper or lower button.
3. Press the middle button to confirm.
Setting internal parameters
1. Press the upper button for 3 seconds. In display the first parameter appears (ro1).
2. Press the middle button to read out value.
3. Change value with upper or lower button.
4. Press the middle button to confirm.
5. Press the lower button for the next parameter. follow instructions 2 to 4.
When no key is pressed after last confirmation, system goes back to normal operation
mode after 20 seconds.