FLUE GAS ANALYSER
1. With
the flue gas analyzer you can measure the exhaust gas on the rotisserie for toxicity. With the use
of a Testo 330-1LL you get the following measurements:
2. Values below are references and factory defaults.
RPM [min-1]
CO2 [%]
Power Hs in [kW]
Power Hs in [BTU]
High load
6350
9,70 %
24
82000
Low load
2500
9,20 %
8,9
30368
Start load
4640
17,5
59030
GAS CONSUMPTION
1. With
a flow meter you can measure the gas consumption/flow. See table on page 4.
2. To get an accurate consumption you have to do a measurement of 3-5 minutes. During this period the
rotisserie may not be turned off and no other gas device on the same gas line may be active.