Cool-Spot in operation

8. Washing and Maintenance AIR SOCKS KE-Low Impulse® /

  KE-Interior® /KE-DireJet® Systems

WASHING AND MAINTENANCE

Wash Air Socks at 20-40°

C

 with regular detergent for 

approximately 5-15 minutes at a time until the laundry 
water is completely clean.

 

Rinse in water at decreasing temperature.

For the second to last rinsing cycle, a disinfectant may 
be added to the “rinse” water. 

Allow the hose to drain, centrifuge at a reduced rate or 
hang to dry while dripping wet.

Draining is recommended at low temperature 
(max. 60°

C

 outgoing air). Drying is allowed but there is a 

risk of shrinking.
 
In the case of persistent stains, soak the air-socks in 
detergent white wash for a couple of hours in advance!!

C

ool-

S

pot

 

1

2

3

4

15

User Manual

Cool-Spot.nl

Summary of Contents for Cool-Spot

Page 1: ...User Manual V3 ...

Page 2: ......

Page 3: ...l Spot controls operation and side effects 5 Side effects of Cool Spot usage in various circumstances 6 Attention Display notifications explanation and desired actions 8 FAQ Troubleshooting 11 Tips for achieving the maximum cooling effect 12 Mi light LED control 13 Washing and maintenance AIR SOCKS 15 1 2 4 3 5 6 7 8 ...

Page 4: ...layed next to On Tap 1 x for 20 vapour Tap 5 x for 100 vapour Tap once or several times The vapour drops in 5 steps Deactivating Cool Spot Tap the on off symbol The display turns dark The LED lighting switches off Off is displayed in the left corner The system will continue to ventilate for another 45 minutes Cool spot NL R FRESH TECHNOLOGY Cool spot NL R FRESH TECHNOLOGY Cool spot NL R FRESH TECH...

Page 5: ...nal the air temperature will drop from the ambient temperature to a value of around 4 5 C The temperature control of the CS system ensures that the outgoing air temperature remains between 5 and 2 degrees Celsius A temperature of 3 4 C will be displayed on the screen periodically This indicates that the cooling system is defrosting until that air temperature has been reached After a brief moment t...

Page 6: ...ust vapour to lower the risk of condensation Buffet or work surface temperature and condensation Upon activation of the Cool Spot system the buffet or work surface has the same temperature as its surroundings The vapour infused cold air from the console reduces the temperature of the surface and the area above it up to approximately 5 6 C This does not cause any condensation on the surface or the ...

Page 7: ...ve effect However this will also cause the majority of the climate to be forced across the surface which will increase the rate of energy loss and decrease the cooling effect What can you do to reduce the effect of draughts If you notice that the pattern of vapour outflow is subject to strong fluctuations is being blown away or pulled underneath the console upon activating or deactivating the exha...

Page 8: ...p transporting the condensated water to the drain has been contaminated with micro fat particles aerosols that the cooling unit has filtered from the ambient air The system deacti vates the cooling unit the surface temperature increases Action Replace or clean the condensation water pump Backup condensate pump Cool Spot has a backup condensate pump next to the main con densate pump If the main con...

Page 9: ...on units with internal condensing unit This fault resets automatically if this message regularly appears the CS system probably has a shortage of refrigerant Action Call email service Cool spot NL R FRESH TECHNOLOGY Cool spot NL R FRESH TECHNOLOGY CoolSpot On Attention Interim Defrost cycle Cool spot NL R FRESH TECHNOLOGY CoolSpot on Low pressure cooling malfuntion auto reset CoolSpot On Attention...

Page 10: ... from the supply valve Reset procedure Turn off the tap on which the stop is mounted On the drain side of the stop completely unscrew the cable gland with the blue 6 mm plastic pipe from the water stop Unscrew the water stop itself approx 1 5 turns from the tap until it is pressure free keep a cloth at hand as some drops of water will be released With a blunt object press the small red reset butto...

Page 11: ...it check whether the black button of the Iskra MS 25 16 switch is enabled 1 Vapour memory has been erased press a few times on 2 The fan is defective the display shows Fan Off call your own Technical Department check supply voltage replace fan 1 Cool Spot has been working for more than a year the nebuliser element is becoming worn and should be replaced consult your own Technical Department Option...

Page 12: ... melamine wood or other insulating material Dark coarse stone like material works better than white shiny plastic that repels cold Buffet tops made of marble granite or hard stone are better than composite Composite contains synthetic resin which has an insulating effect and is slow to absorb cooling energy Light coloured and smoothly polished buffet tops appear to have an insulating effect An imp...

Page 13: ...en this mode is on The brightness of the light can then be determined with the Brightness ring The indicator light is on when one of the functions is pressed if it is not lit and you are actually using one of the functions the batteries are probably empty Indicator light Brightness Brightness Master ON Modes programs 4x un Link Light Speed Zone on Zone out Speed Master OFF Color ring 7 Mi light LE...

Page 14: ...t on again When pairing is complete the light flashes 10 times in quick succession When the light is on long press one of the Zone Link buttons Within three seconds after the light came on Unlinking must be done with the same zone as with linking If the light does not flash 10 times quickly the disconnection is not completed please turn off the light again and follow the above steps again If the l...

Page 15: ...water at decreasing temperature For the second to last rinsing cycle a disinfectant may be added to the rinse water Allow the hose to drain centrifuge at a reduced rate or hang to dry while dripping wet Draining is recommended at low temperature max 60 C outgoing air Drying is allowed but there is a risk of shrinking In the case of persistent stains soak the air socks in detergent white wash for a...